Designing a data center involves planning the layout, selecting equipment, ensuring redundancy, and implementing security measures.
Plan the layout of the data center to optimize space and airflow
Select appropriate equipment such as servers, storage devices, and networking gear
Ensure redundancy in power supply, cooling systems, and network connectivity
Implement security measures like access control, surveillance cameras
kW and kVA are units of power measurement in electrical systems.
kW stands for kilowatt and is a unit of real power, representing the actual power consumed by a device or system.
kVA stands for kilovolt-ampere and is a unit of apparent power, which is the combination of real power and reactive power in an electrical system.
The relationship between kW and kVA is influenced by the power factor of the system.
Power factor is...
SMPS stands for Switched Mode Power Supply. It is commonly used in data centers for efficient power conversion.
SMPS is a type of power supply that uses a switching regulator to convert electrical power efficiently.
It is commonly used in data centers to provide stable and efficient power to servers and networking equipment.
SMPS can handle a wide range of input voltages and frequencies, making it versatile for different ...
VRLA stands for Valve Regulated Lead Acid batteries, which are maintenance-free and sealed. They are commonly used in UPS systems and solar power applications.
VRLA batteries are sealed and maintenance-free
They use a gel or absorbent glass mat to immobilize the electrolyte
Commonly used in UPS systems, solar power applications, and telecommunications
Lead acid batteries are rechargeable batteries that use lead electrodes
The KVA rating of a DG is determined based on the connected load and power factor of the system.
Calculate the total connected load in kilowatts (kW)
Consider the power factor of the system
Use the formula: KVA = kW / power factor
Round up to the nearest standard KVA rating available
HVAC load refers to the amount of heating or cooling needed to maintain a comfortable indoor temperature in a building.
HVAC load is calculated based on factors such as the size of the building, insulation levels, number of occupants, and climate conditions.
It is important to accurately determine HVAC load to properly size heating and cooling equipment.
Examples of factors affecting HVAC load include sunlight exposure, a...
Improving data center PUE involves optimizing energy usage and efficiency.
Implementing hot aisle/cold aisle containment to reduce energy waste
Upgrading to more energy-efficient servers and cooling systems
Utilizing virtualization to increase server utilization and reduce energy consumption
Regularly monitoring and adjusting temperature and humidity levels for optimal efficiency
posted on 26 Dec 2021
I appeared for an interview before Dec 2020.
I applied via Campus Placement and was interviewed before Feb 2023. There were 2 interview rounds.
Normal GD.Just brush up contemporary topics
I applied via Company Website and was interviewed before Aug 2021. There were 2 interview rounds.
Technical questions.
posted on 24 Jul 2017
A lease can be terminated through mutual agreement, expiration, breach, or eviction.
Mutual agreement: Both parties agree to end the lease before the agreed-upon term.
Expiration: The lease ends naturally after the agreed-upon term.
Breach: One party violates the terms of the lease, allowing the other party to terminate it.
Eviction: The landlord legally removes the tenant from the property due to non-payment or other viol
I appeared for an interview in Apr 2017.
Motivating a team involves setting clear goals, providing support, recognizing achievements, and fostering a positive work environment.
Set clear and achievable goals for the team to work towards
Provide support and resources to help team members succeed
Recognize and reward individual and team achievements
Foster a positive work environment through open communication and collaboration
Lead by example and show enthusiasm fo
EV stands for electric vehicle. EV charging stations benefit consumers by providing convenient and fast charging options for their electric vehicles.
EV stands for electric vehicle, which runs on electricity instead of gasoline.
EV charging stations provide convenient and fast charging options for EV owners, allowing them to charge their vehicles at home or on the go.
Consumers can benefit from reduced fuel costs and lowe...
I will establish clear expectations, provide necessary resources, monitor progress regularly, and address any issues promptly.
Establish clear expectations and goals for the contractors
Provide necessary resources and support for the contractors to succeed
Monitor progress regularly and communicate with contractors to ensure alignment
Address any issues or concerns promptly and provide feedback for improvement
Personal Protective Equipment (PPE) at a site refers to gear worn to minimize exposure to hazards.
Hard hats for head protection
Safety goggles for eye protection
Gloves for hand protection
Steel-toed boots for foot protection
High visibility vests for visibility
Quality standards for EV charger erection ensure safety, efficiency, and compliance with regulations.
Adherence to relevant safety regulations and standards (e.g. NEC, UL)
Proper installation by certified technicians
Thorough testing of the charger before operation
Ensuring compatibility with the electrical system and vehicle requirements
Regular maintenance and inspection to prevent malfunctions
The electrical and communication wire execution process with single tranch involves a streamlined approach to installing wires in a single pass.
Plan the layout of the wires to ensure efficient installation in a single tranch
Use appropriate tools and equipment for the job
Ensure proper insulation and protection of the wires
Test the connections to ensure functionality
Document the process for future reference
Maintaining a 150mm minimum distance between Electrical & Communication cables in a single trench is crucial for safety and efficiency.
Ensure proper separation between Electrical & Communication cables to prevent interference and potential hazards
Use cable trays or separate trenches to maintain the required distance
Follow industry standards and regulations for cable laying practices
Regularly inspect and maintain the ca
The statement is contradictory and does not make sense.
The statement 'Best eating accuracy is zero' is nonsensical as accuracy is typically measured on a scale from 0 to 100.
Conductive materials surrounding electrical wires or machinery typically have voltage limiting properties to prevent electrical hazards.
It is important to ensure proper grounding of conductive materials to prevent electrical shocks or fires.
I applied via Naukri.com and was interviewed in Sep 2023. There were 3 interview rounds.
End to end project management
posted on 7 Sep 2024
based on 2 interviews
Interview experience
based on 4 reviews
Rating in categories
Manager
3.4k
salaries
| ₹5.4 L/yr - ₹19.7 L/yr |
Field Executive
2.7k
salaries
| ₹1.8 L/yr - ₹9.4 L/yr |
Assistant Manager
2.7k
salaries
| ₹1.8 L/yr - ₹10 L/yr |
Senior Manager
2.5k
salaries
| ₹8 L/yr - ₹28 L/yr |
Senior Executive
1.1k
salaries
| ₹1.8 L/yr - ₹8.5 L/yr |
Indian Oil Corporation
Shell
Bharat Petroleum
Hindustan Petroleum