PVR Inox
10+ Celesty Ice Cream Interview Questions and Answers
Q1. Which contactor connected first in star delta starter?
The main contactor is connected first in a star delta starter.
The main contactor is connected to the three-phase power supply.
The main contactor is responsible for supplying power to the motor.
The delta contactor is then connected to the motor windings.
The star contactor is connected last to complete the circuit.
This method is used to reduce the starting current of the motor.
Q2. Safety of dry transformer and how's it work?
Dry transformers are safe due to their insulation system and lack of flammable liquids.
Dry transformers use solid insulation materials to prevent electrical arcing and fires.
They do not contain flammable liquids like oil-filled transformers.
Dry transformers are often used in indoor settings where fire safety is a concern.
Regular maintenance and testing is important to ensure the safety and efficiency of dry transformers.
Q3. What is the process of Chiller plant operation?
Chiller plant operation involves a process of cooling water using a refrigerant and circulating it through a closed loop system.
The chiller plant consists of a compressor, condenser, evaporator, and expansion valve.
The compressor compresses the refrigerant gas, which then flows to the condenser where it is cooled and condensed into a liquid.
The liquid refrigerant then flows to the evaporator where it absorbs heat from the water, which is then circulated through the building t...read more
Q4. Why we are considering dry type transformer?
Dry type transformers are considered for safety, environmental, and maintenance reasons.
Dry type transformers are safer than oil-filled transformers as they do not pose a fire hazard.
They are also more environmentally friendly as they do not contain oil that can leak and cause pollution.
Dry type transformers require less maintenance than oil-filled transformers as they do not need oil testing or replacement.
They are also smaller and lighter than oil-filled transformers, makin...read more
Q5. Safety of DG set and how's is works?
DG sets are safe if maintained properly. They work by converting fuel into electrical energy through combustion.
DG sets should be installed in well-ventilated areas to prevent carbon monoxide poisoning.
Regular maintenance and servicing is necessary to ensure safe operation.
Proper grounding and earthing is essential to prevent electrical hazards.
DG sets should be equipped with safety features such as automatic shutdown in case of overload or low oil pressure.
DG sets work by co...read more
Q6. How to connect the LAN cable connector?
To connect a LAN cable connector, follow these steps:
Identify the LAN port on your device
Insert the connector into the port until it clicks into place
Ensure the connector is securely connected by gently tugging on the cable
Repeat the process on the other end of the cable, connecting it to the router or modem
Check for a stable internet connection
Q7. Oil based transformer BDV test unit?
Oil based transformer BDV test unit is a device used to measure the breakdown voltage of transformer oil.
BDV test unit is used to determine the quality of transformer oil.
It measures the voltage at which the oil breaks down and becomes conductive.
This test is important to ensure the proper functioning of the transformer.
The test unit applies a voltage to the oil and measures the current flow.
If the current exceeds a certain level, the oil is considered to have failed the test...read more
Q8. Chiller plant de-scaling process?
Chiller plant de-scaling process involves removing mineral deposits from the chiller tubes to improve efficiency.
The process involves shutting down the chiller plant and draining the water from the system.
Acidic solutions are then circulated through the chiller tubes to dissolve the mineral deposits.
After the solution has been circulated for a specific amount of time, it is drained and the chiller tubes are flushed with clean water.
The chiller plant is then refilled with wate...read more
Q9. Fire alarm system working process?
Fire alarm system detects fire and alerts occupants and emergency services.
Fire alarm system consists of smoke detectors, heat detectors, and manual pull stations.
When smoke or heat is detected, the alarm sounds and alerts occupants to evacuate.
The alarm also sends a signal to the monitoring station, which alerts emergency services.
Regular maintenance and testing of the system is necessary to ensure proper functioning.
Q10. Elevator fly wheel working process?
Elevator flywheel stores kinetic energy to provide backup power during power outages.
Flywheel is connected to the elevator motor and spins continuously.
During normal operation, the flywheel stores kinetic energy.
In case of a power outage, the flywheel continues to spin and provides backup power to the elevator motor.
This allows the elevator to safely descend to the nearest floor and open its doors.
Flywheels are commonly used in high-rise buildings and hospitals where power ou...read more