Motor megger value should be at least twice the rated voltage of the motor. Cable size should be selected based on the full load current of the motor.
Motor megger value should be at least 2 times the rated voltage of the motor to ensure insulation integrity.
Cable size should be selected based on the full load current of the motor to prevent overheating and voltage drop.
For example, for a motor rated at 400V, the megger...
OLR value of a motor is determined by the rating of the motor and the MPCB rating.
OLR value is the Overload Relay value, which is used to protect the motor from overload conditions.
The OLR value is typically set based on the rating of the motor and the rating of the Motor Protection Circuit Breaker (MPCB).
For example, if a motor has a rating of 5 HP and the MPCB rating is 10A, the OLR value would be calculated accordin
I applied via Walk-in and was interviewed in Jul 2021. There was 1 interview round.
posted on 28 Jul 2023
I applied via Walk-in and was interviewed before Jul 2022. There were 3 interview rounds.
posted on 25 Dec 2023
I applied via Recruitment Consulltant and was interviewed before Dec 2022. There were 2 interview rounds.
Motor megger value should be at least twice the rated voltage of the motor. Cable size should be selected based on the full load current of the motor.
Motor megger value should be at least 2 times the rated voltage of the motor to ensure insulation integrity.
Cable size should be selected based on the full load current of the motor to prevent overheating and voltage drop.
For example, for a motor rated at 400V, the megger...
OLR value of a motor is determined by the rating of the motor and the MPCB rating.
OLR value is the Overload Relay value, which is used to protect the motor from overload conditions.
The OLR value is typically set based on the rating of the motor and the rating of the Motor Protection Circuit Breaker (MPCB).
For example, if a motor has a rating of 5 HP and the MPCB rating is 10A, the OLR value would be calculated accordin
posted on 4 Jun 2022
I applied via Walk-in and was interviewed before Jun 2021. There were 4 interview rounds.
I applied via Walk-in and was interviewed in Jul 2021. There was 1 interview round.
based on 8 reviews
Rating in categories
Junior Manager
101
salaries
| ₹3.4 L/yr - ₹11 L/yr |
Junior Officer
77
salaries
| ₹2.6 L/yr - ₹7 L/yr |
Assistant Manager
56
salaries
| ₹6.5 L/yr - ₹13.2 L/yr |
Senior Executive
48
salaries
| ₹3.4 L/yr - ₹7.2 L/yr |
Junior Engineer
45
salaries
| ₹2.7 L/yr - ₹7 L/yr |
Tata Steel
JSW Steel
Steel Authority Of India
ArcelorMittal Nippon Steel