I applied via Walk-in and was interviewed before Aug 2022. There were 2 interview rounds.
Base shear can be calculated using the seismic coefficient method or the equivalent lateral force method.
Base shear can be calculated using the formula: V = Cs * W, where Cs is the seismic coefficient and W is the total weight of the structure.
Seismic coefficient can be determined based on the seismic zone and the type of structure.
Equivalent lateral force method involves calculating the total lateral force acting on t...
The CF value for a pipe rack is typically determined based on the specific design requirements and load conditions.
CF value stands for Capacity Factor, which is used to determine the load capacity of a pipe rack structure.
The CF value can vary depending on factors such as material type, design codes, and safety factors.
Calculating the CF value involves considering the maximum load the pipe rack will need to support and...
The question is asking about the load factor for pipe rack and pipes.
cf is 2 for pipe rack and 0.7 for pipes
cf stands for load factor
The load factor for pipe rack is higher than for pipes
Top trending discussions
posted on 22 Oct 2024
I applied via Company Website and was interviewed before Oct 2023. There was 1 interview round.
Designed and analyzed a multi-story residential building using software like ETABS and STAAD Pro.
Designed structural elements such as beams, columns, and slabs to ensure safety and stability.
Analyzed the building for various loads including dead, live, wind, and seismic loads.
Used software like ETABS and STAAD Pro for structural analysis and design.
Collaborated with architects and other engineers to ensure the structur...
posted on 1 Jun 2024
I was interviewed before Jun 2023.
posted on 18 Dec 2021
I was interviewed in Jun 2021.
The loads considered in telecom towers design include wind loads, dead loads, ice loads, and equipment loads.
Wind loads: Towers are designed to withstand the force of wind at different speeds and directions.
Dead loads: These include the weight of the tower structure itself and any permanent fixtures.
Ice loads: Towers in cold climates need to be designed to support the weight of ice accumulation.
Equipment loads: The wei...
Wind load calculation as per IS875 involves determining the wind pressure acting on the structure and calculating the resultant force.
Wind pressure is calculated based on the wind speed and the terrain category of the site
The pressure coefficients for different parts of the structure are determined based on the shape and orientation of the surface
The wind load acting on the structure is calculated by multiplying the pr...
posted on 23 Apr 2022
I applied via Approached by Company and was interviewed before Apr 2021. There were 2 interview rounds.
based on 4 reviews
Rating in categories
Piping Designer
118
salaries
| ₹1.8 L/yr - ₹6.5 L/yr |
Piping Design Engineer
86
salaries
| ₹1.3 L/yr - ₹6 L/yr |
Design Engineer
21
salaries
| ₹1.2 L/yr - ₹7.2 L/yr |
Structural Designer
17
salaries
| ₹1.4 L/yr - ₹7.5 L/yr |
Electrical Designer
16
salaries
| ₹2.5 L/yr - ₹6.5 L/yr |
L&T Energy Hydrocarbon
TCE
TechnipFMC
Toyo Engineering