Filter interviews by
Debit and credit are accounting terms used to record financial transactions in a company's general ledger.
Debit is an entry on the left side of an account, representing an increase in assets or a decrease in liabilities or equity.
Credit is an entry on the right side of an account, representing a decrease in assets or an increase in liabilities or equity.
Debits must equal credits in every transaction to maintain th...
Welding defects can be improved by identifying root causes, implementing proper training, using high-quality materials, and conducting regular inspections.
Identify root causes of welding defects such as improper technique, incorrect settings, or poor material quality
Implement proper training for welders to ensure they are using correct techniques and settings
Use high-quality materials for welding to reduce the cha...
To reduce Running Fan vibration and failure, proper maintenance, balancing, alignment, and regular inspection are essential.
Regularly clean the fan blades and housing to prevent buildup of dirt and debris
Ensure proper alignment of the fan blades and motor shaft
Balancing the fan blades to reduce vibration
Inspect and replace worn out bearings or belts
Check for loose or damaged components and tighten or replace as ne...
To improve the quality of FRP panels, focus on material selection, manufacturing processes, quality control measures, and continuous improvement.
Select high-quality raw materials to ensure durability and strength of FRP panels.
Implement strict manufacturing processes to maintain consistency and reduce defects.
Establish quality control measures at each stage of production to identify and address issues promptly.
Inv...
Cooling towers are heat rejection devices used to transfer process waste heat to the atmosphere.
Cooling towers are used in HVAC systems, power plants, and other industrial settings.
They work by evaporating water to remove heat from the system.
There are two main types of cooling towers: natural draft and mechanical draft.
Cooling towers require regular maintenance to prevent issues such as scale buildup and Legionel...
I will ask the client to provide more information about the product and do my own research to understand it better.
Ask the client to describe the product in detail
Research the product online or through company resources
Consult with colleagues or superiors for more information
Provide the client with accurate information once fully informed
Gear box ratio can be calculated by dividing the number of teeth on the driven gear by the number of teeth on the driving gear.
Calculate the number of teeth on the driving gear and the driven gear.
Divide the number of teeth on the driven gear by the number of teeth on the driving gear to get the gear box ratio.
To improve quality, ensure proper lubrication, alignment, and maintenance of the gear box components.
Regu...
Galvanizing process involves coating steel with a layer of zinc to prevent corrosion. Quality can be checked through visual inspection, thickness measurement, adhesion tests, and salt spray tests.
Galvanizing process involves cleaning the steel surface, dipping it in a bath of molten zinc, and then cooling it.
Quality can be checked visually for any defects such as bare spots, drips, or rough areas.
Thickness measure...
India's tax system includes various direct and indirect taxes, impacting individuals and businesses significantly.
Income Tax: Progressive tax rates based on income slabs; for example, 5% for income up to ₹2.5 lakh.
Goods and Services Tax (GST): A unified tax on goods and services; rates vary from 0% to 28%.
Corporate Tax: Standard rate of 30% for domestic companies, with lower rates for new manufacturing firms.
Capit...
I applied via Walk-in and was interviewed in May 2024. There was 1 interview round.
Galvanizing process involves coating steel with a layer of zinc to prevent corrosion. Quality can be checked through visual inspection, thickness measurement, adhesion tests, and salt spray tests.
Galvanizing process involves cleaning the steel surface, dipping it in a bath of molten zinc, and then cooling it.
Quality can be checked visually for any defects such as bare spots, drips, or rough areas.
Thickness measurement ...
Welding defects can be improved by identifying root causes, implementing proper training, using high-quality materials, and conducting regular inspections.
Identify root causes of welding defects such as improper technique, incorrect settings, or poor material quality
Implement proper training for welders to ensure they are using correct techniques and settings
Use high-quality materials for welding to reduce the chances ...
To improve the quality of FRP panels, focus on material selection, manufacturing processes, quality control measures, and continuous improvement.
Select high-quality raw materials to ensure durability and strength of FRP panels.
Implement strict manufacturing processes to maintain consistency and reduce defects.
Establish quality control measures at each stage of production to identify and address issues promptly.
Invest i...
Gear box ratio can be calculated by dividing the number of teeth on the driven gear by the number of teeth on the driving gear.
Calculate the number of teeth on the driving gear and the driven gear.
Divide the number of teeth on the driven gear by the number of teeth on the driving gear to get the gear box ratio.
To improve quality, ensure proper lubrication, alignment, and maintenance of the gear box components.
Regularly...
To reduce Running Fan vibration and failure, proper maintenance, balancing, alignment, and regular inspection are essential.
Regularly clean the fan blades and housing to prevent buildup of dirt and debris
Ensure proper alignment of the fan blades and motor shaft
Balancing the fan blades to reduce vibration
Inspect and replace worn out bearings or belts
Check for loose or damaged components and tighten or replace as needed
30mins,time,profit and loss,clock
30mins,Arrays,Hashing,stack
I appeared for an interview in May 2025, where I was asked the following questions.
India's tax system includes various direct and indirect taxes, impacting individuals and businesses significantly.
Income Tax: Progressive tax rates based on income slabs; for example, 5% for income up to ₹2.5 lakh.
Goods and Services Tax (GST): A unified tax on goods and services; rates vary from 0% to 28%.
Corporate Tax: Standard rate of 30% for domestic companies, with lower rates for new manufacturing firms.
Capital Ga...
GST in India is a comprehensive tax on the supply of goods and services, aimed at simplifying the tax structure.
GST is a single tax system replacing multiple indirect taxes like VAT, Service Tax, and Excise Duty.
It is categorized into three types: CGST (Central GST), SGST (State GST), and IGST (Integrated GST) for inter-state transactions.
GST rates vary from 0% to 28%, with essential goods often taxed at lower rates (e...
Aptitude test was hard
I am a dedicated and organized individual with a passion for sales and customer service.
Strong communication skills to effectively interact with customers and team members
Detail-oriented approach to ensure accuracy in sales reports and data analysis
Proven track record of exceeding sales targets through strategic planning and execution
Discussed technically
Debit and credit are accounting terms used to record financial transactions in a company's general ledger.
Debit is an entry on the left side of an account, representing an increase in assets or a decrease in liabilities or equity.
Credit is an entry on the right side of an account, representing a decrease in assets or an increase in liabilities or equity.
Debits must equal credits in every transaction to maintain the acc...
God questions will be asked all are easy to medium hard
I appeared for an interview in Oct 2023.
10 question were asked
2 question asked in this
I applied via Approached by Company and was interviewed before Sep 2022. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Jun 2021. There were 6 interview rounds.
Cooling towers are heat rejection devices used to transfer process waste heat to the atmosphere.
Cooling towers are used in HVAC systems, power plants, and other industrial settings.
They work by evaporating water to remove heat from the system.
There are two main types of cooling towers: natural draft and mechanical draft.
Cooling towers require regular maintenance to prevent issues such as scale buildup and Legionella gr...
I will ask the client to provide more information about the product and do my own research to understand it better.
Ask the client to describe the product in detail
Research the product online or through company resources
Consult with colleagues or superiors for more information
Provide the client with accurate information once fully informed
Top trending discussions
Some of the top questions asked at the Paltech Cooling Towers & Equipments interview -
based on 13 interview experiences
Difficulty level
Duration
based on 58 reviews
Rating in categories
Assistant Manager
6
salaries
| ₹4.8 L/yr - ₹8.4 L/yr |
Senior HR Executive
6
salaries
| ₹3 L/yr - ₹4.2 L/yr |
Sales Coordinator
5
salaries
| ₹3 L/yr - ₹5.2 L/yr |
Senior Sales Coordinator
5
salaries
| ₹4.2 L/yr - ₹5 L/yr |
Executive Accountant
5
salaries
| ₹2.6 L/yr - ₹3.6 L/yr |
Gilbarco Veeder Root
HYT Engineering
Kirloskar Toyota Textile Machinery
Hyundai Construction Equipment