FCU stands for Fan Coil Unit, which is a device that contains a fan and a heat exchanger to regulate air temperature.
FCU is commonly used in HVAC systems to provide heating or cooling to a space.
It works by drawing in air from the room, passing it over a heat exchanger, and then blowing it back out into the room.
FCUs can be wall-mounted, ceiling-mounted, or floor-mounted depending on the space and design requireme...
Return duct is a part of HVAC system that carries air from a room back to the air handler to be conditioned and recirculated.
Return ducts are typically larger in size than supply ducts to accommodate the volume of air being returned.
They can be located in walls, ceilings, or floors depending on the design of the building.
Return ducts can also have filters installed to remove dust and other particles from the air b...
VCD stands for Volume Control Damper, which is used to regulate the airflow in HVAC systems.
VCD is a type of damper that is installed in HVAC ducts to control the volume of air flowing through them.
It is typically made of galvanized steel and has blades that can be adjusted to regulate the airflow.
VCDs are commonly used in commercial and industrial HVAC systems to maintain proper air balance and temperature contro...
Access door is an inspection way of inside the installed duct.
Access doors are used to provide easy access to the inside of the duct for inspection, cleaning, and maintenance purposes.
They are typically installed at regular intervals along the length of the duct.
Access doors can be made of various materials such as metal, plastic, or fiberglass.
They come in different sizes and shapes depending on the size and shap...
FD stands for Fire Damper, which is a device installed in HVAC ducts to prevent the spread of fire and smoke.
FD is a crucial component of fire protection systems in buildings.
It is designed to automatically close when it detects heat or smoke, preventing the spread of fire and smoke through the ducts.
FDs are required by building codes to be installed in certain locations, such as walls, floors, and ceilings, to co...
The supply duct is responsible for delivering cool air from the unit to the room.
Supply ducts are typically made of metal or flexible material and are installed in the walls, floors, or ceilings of a building.
They are connected to the air conditioning unit and distribute cool air throughout the building.
Properly sized and installed supply ducts ensure that each room receives the appropriate amount of cool air.
Regu...
There are four types of ducts: supply duct, return duct, fresh air duct, and exhaust duct.
Supply ducts carry conditioned air from the HVAC system to the rooms.
Return ducts carry air from the rooms back to the HVAC system.
Fresh air ducts bring in outside air to improve indoor air quality.
Exhaust ducts remove stale air and pollutants from the building.
There are various types of grills used in HVAC ducting such as return, supply, fresh air, exhaust, and transfer grills.
Return grills are used to extract air from a room and return it to the HVAC system.
Supply grills are used to supply conditioned air to a room.
Fresh air grills are used to bring in fresh air from outside.
Exhaust grills are used to remove stale air from a room.
Transfer grills are used to transfer ai...
HVAC stands for Heating, Ventilation, and Air Conditioning. It refers to the technology used for indoor environmental comfort.
HVAC systems are used to regulate temperature, humidity, and air quality in buildings.
They can include components such as furnaces, air conditioners, ductwork, and ventilation fans.
Properly designed and maintained HVAC systems can improve energy efficiency and indoor air quality.
HVAC techni...
I applied via Approached by Company and was interviewed in Oct 2022. There was 1 interview round.
HVAC stands for Heating, Ventilation, and Air Conditioning. It refers to the technology used for indoor environmental comfort.
HVAC systems are used to regulate temperature, humidity, and air quality in buildings.
They can include components such as furnaces, air conditioners, ductwork, and ventilation fans.
Properly designed and maintained HVAC systems can improve energy efficiency and indoor air quality.
HVAC technicians...
FCU stands for Fan Coil Unit, which is a device that contains a fan and a heat exchanger to regulate air temperature.
FCU is commonly used in HVAC systems to provide heating or cooling to a space.
It works by drawing in air from the room, passing it over a heat exchanger, and then blowing it back out into the room.
FCUs can be wall-mounted, ceiling-mounted, or floor-mounted depending on the space and design requirements.
E...
FD stands for Fire Damper, which is a device installed in HVAC ducts to prevent the spread of fire and smoke.
FD is a crucial component of fire protection systems in buildings.
It is designed to automatically close when it detects heat or smoke, preventing the spread of fire and smoke through the ducts.
FDs are required by building codes to be installed in certain locations, such as walls, floors, and ceilings, to compart...
Access door is an inspection way of inside the installed duct.
Access doors are used to provide easy access to the inside of the duct for inspection, cleaning, and maintenance purposes.
They are typically installed at regular intervals along the length of the duct.
Access doors can be made of various materials such as metal, plastic, or fiberglass.
They come in different sizes and shapes depending on the size and shape of ...
There are various types of grills used in HVAC ducting such as return, supply, fresh air, exhaust, and transfer grills.
Return grills are used to extract air from a room and return it to the HVAC system.
Supply grills are used to supply conditioned air to a room.
Fresh air grills are used to bring in fresh air from outside.
Exhaust grills are used to remove stale air from a room.
Transfer grills are used to transfer air fro...
VCD stands for Volume Control Damper, which is used to regulate the airflow in HVAC systems.
VCD is a type of damper that is installed in HVAC ducts to control the volume of air flowing through them.
It is typically made of galvanized steel and has blades that can be adjusted to regulate the airflow.
VCDs are commonly used in commercial and industrial HVAC systems to maintain proper air balance and temperature control.
The...
There are four types of ducts: supply duct, return duct, fresh air duct, and exhaust duct.
Supply ducts carry conditioned air from the HVAC system to the rooms.
Return ducts carry air from the rooms back to the HVAC system.
Fresh air ducts bring in outside air to improve indoor air quality.
Exhaust ducts remove stale air and pollutants from the building.
The supply duct is responsible for delivering cool air from the unit to the room.
Supply ducts are typically made of metal or flexible material and are installed in the walls, floors, or ceilings of a building.
They are connected to the air conditioning unit and distribute cool air throughout the building.
Properly sized and installed supply ducts ensure that each room receives the appropriate amount of cool air.
Regular m...
Return duct is a part of HVAC system that carries air from a room back to the air handler to be conditioned and recirculated.
Return ducts are typically larger in size than supply ducts to accommodate the volume of air being returned.
They can be located in walls, ceilings, or floors depending on the design of the building.
Return ducts can also have filters installed to remove dust and other particles from the air before...
Top trending discussions
I applied via Recruitment Consultant and was interviewed in Feb 2020. There were 5 interview rounds.
I appeared for an interview in Mar 2025, where I was asked the following questions.
I applied via Referral and was interviewed before Jun 2023. There was 1 interview round.
I applied via Company Website and was interviewed in Mar 2021. There were 4 interview rounds.
The procedure for erecting a Heat Exchanger involves several steps including site preparation, foundation installation, equipment placement, piping connection, and testing.
Prepare the site by leveling the ground and ensuring adequate space for the equipment
Install the foundation to support the weight of the Heat Exchanger
Place the Heat Exchanger on the foundation and secure it in place
Connect the piping to the Heat Exc...
Precautions before starting confined space work
Identify the confined space and assess the hazards
Ensure proper ventilation and air quality testing
Use appropriate personal protective equipment
Have a rescue plan in place and train all workers involved
Obtain necessary permits and follow all safety regulations
Communicate clearly with all workers involved in the job
Alignment of a column can be checked using various methods.
Visual inspection can be done to check if the column is straight and vertical.
Laser alignment tools can be used to check the alignment of the column.
String lines can be used to check the alignment of the column.
Plumb bobs can be used to check the vertical alignment of the column.
Optical instruments like theodolites can be used to check the alignment of the colu...
Acceptance limit for column alignment is typically 1/500th of the column height.
The acceptance limit for column alignment is usually specified in the project specifications.
It is typically 1/500th of the column height.
This means that for a 20-meter column, the maximum allowable deviation from vertical is 40 mm.
Alignment is critical for the proper functioning of the column and to prevent damage to the structure.
Alignmen...
I applied via Walk-in and was interviewed in Jul 2022. There were 2 interview rounds.
Pipe supports are used to hold and position pipes in various applications.
Pipe hangers: Used to suspend pipes from ceilings or walls.
Pipe clamps: Used to secure pipes to structural supports.
Pipe shoes: Used to support pipes on flat surfaces.
Spring supports: Used to absorb vibrations and provide flexibility.
Rigid supports: Used to provide fixed support to pipes.
Variable supports: Used to accommodate thermal expansion an...
Piping of pump involves selecting appropriate pipe size, routing, and supporting the pipe to avoid stress and vibration.
Select pipe size based on pump flow rate and pressure requirements
Route the pipe to minimize friction loss and avoid obstacles
Support the pipe adequately to avoid stress and vibration
Use appropriate fittings and valves to connect the pump to the piping system
Consider the material of the pipe and fitti...
WHAT IS NPHSA AND WHAT IS PIPING STANDARD AND WHAT IS EQUPIPMENT LAYOUT
posted on 28 Jul 2024
posted on 5 Jul 2020
I appeared for an interview before Jul 2019.
Some of the top questions asked at the Nasser S. Al Hajri Corporation Hvac Ducting Supervisor interview -
based on 1 review
Rating in categories
Piping Engineer
71
salaries
| ₹5 L/yr - ₹18 L/yr |
Piping Supervisor
59
salaries
| ₹4 L/yr - ₹16 L/yr |
Planning Engineer
43
salaries
| ₹5.8 L/yr - ₹15.2 L/yr |
QC Inspector
41
salaries
| ₹8.7 L/yr - ₹15 L/yr |
Electrical Engineer
39
salaries
| ₹6.4 L/yr - ₹14.6 L/yr |
Alstom Transportation
Saint-Gobain
AECOM
AtkinsRealis