Filter interviews by
Be the first one to contribute and help others!
I applied via Newspaper Ad and was interviewed before Feb 2022. There was 1 interview round.
Had the coding round and we have to solve the find nth largest element.
posted on 18 Dec 2024
I applied via LinkedIn and was interviewed before Dec 2023. There were 3 interview rounds.
posted on 16 Jan 2025
I applied via Campus Placement
Mostly Aptitude, Reasoning,Verbal in the round-1 with 60 questions
2 programming questions - you can select which language u are comfortable
I was interviewed before Feb 2024.
I was interviewed before Jun 2023.
Logical+ Attitude +Math
I was interviewed before Apr 2023.
Simple basic application
I applied via Referral and was interviewed in Nov 2022. There were 3 interview rounds.
Accrual concept recognizes revenue and expenses when they are earned/incurred, regardless of when cash is received/paid. Accounting standards provide guidelines for financial reporting.
Accrual concept is based on matching revenue and expenses in the same accounting period
Revenue is recognized when it is earned, not when cash is received
Expenses are recognized when they are incurred, not when cash is paid
Accounting stan...
posted on 16 Dec 2023
I applied via LinkedIn and was interviewed in Jun 2023. There were 2 interview rounds.
The hipot test can be done on a cable multiple times depending on the specific requirements and standards.
The number of times a hipot test can be done on a cable depends on the cable's specifications and the testing requirements.
Generally, a hipot test is performed once during the manufacturing process to ensure the cable's insulation integrity.
However, additional hipot tests may be conducted during the cable's lifespa...
If battery polarity is inverse with respect to battery charger, it can lead to damage or malfunction.
Inverse polarity can cause short circuits or overheating.
It can damage the battery, charger, or both.
Reverse polarity protection circuits can prevent damage.
Always double-check the polarity before connecting the battery to the charger.
There are several types of earthing used in electrical systems.
The most common types of earthing are:
- TN-S system: Separate neutral and protective earth conductors
- TN-C system: Combined neutral and protective earth conductors
- TN-C-S system: Combination of TN-S and TN-C systems
- TT system: Separate earth electrode for each electrical installation
- IT system: No direct connection between earth and neutral
Each type of ...
I have handled various quality documents such as quality control plans, inspection reports, and non-conformance reports.
Quality control plans
Inspection reports
Non-conformance reports
Tests done on power transformers include insulation resistance, turns ratio, winding resistance, and dielectric tests.
Insulation resistance test checks the insulation quality of the transformer.
Turns ratio test measures the ratio of primary to secondary turns.
Winding resistance test determines the resistance of transformer windings.
Dielectric tests assess the dielectric strength and insulation properties of the transfo...
Hipot testing is a process used to verify the insulation integrity of busbars, breakers, cables, and transformers.
Hipot testing involves applying a high voltage to the component being tested.
The purpose is to check for any insulation breakdown or leakage current.
For busbars and cables, the test is typically performed between the conductor and the ground.
For breakers and transformers, the test is performed between diffe...
IR, WR, and CR are abbreviations used in different contexts. IR stands for Infrared, WR stands for Weather Resistant, and CR stands for Compression Ratio.
IR refers to Infrared, which is a type of electromagnetic radiation with longer wavelengths than visible light.
WR is used to indicate that a product or material is designed to withstand various weather conditions.
CR is a term commonly used in engineering and physics t...
Tap changer in a transformer is located on the high voltage winding side to regulate the voltage output.
Tap changer is typically located on the high voltage winding side of a transformer.
It is used to adjust the turns ratio and regulate the voltage output.
If the voltage output in the secondary decreases, the tap changer will be moved to a higher tap position to increase the voltage.
posted on 9 Nov 2024
I applied via Recruitment Consulltant
based on 20 reviews
Rating in categories
Electrical Engineer
4
salaries
| ₹0 L/yr - ₹0 L/yr |
Operations Executive
4
salaries
| ₹0 L/yr - ₹0 L/yr |
Officer
4
salaries
| ₹0 L/yr - ₹0 L/yr |
Engineer
3
salaries
| ₹0 L/yr - ₹0 L/yr |
Engineer Trainee
3
salaries
| ₹0 L/yr - ₹0 L/yr |
NHAVA SHEVA INTERNATIONAL CONTAINER TERMINAL
Adani International Container Terminal
KRISHNAPATNAM PORT CONTAINER TERMINAL
Gujarat Pipavav Port