An alternator is a device that converts mechanical energy into electrical energy.
Alternators work on the principle of electromagnetic induction.
They consist of a rotor and a stator.
The rotor rotates inside the stator, creating a magnetic field.
This magnetic field induces an electrical current in the stator windings.
The output voltage and frequency of the alternator can be controlled by varying the speed of the rotor an...
I applied via Walk-in and was interviewed before Feb 2021. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Dec 2020. There were 3 interview rounds.
I applied via Referral and was interviewed before Sep 2020. There were 3 interview rounds.
I applied via Referral and was interviewed before Oct 2021. There were 3 interview rounds.
Siemens plc models include S7-1200, S7-1500, S7-300, S7-400, and LOGO!
S7-1200
S7-1500
S7-300
S7-400
LOGO!
SPC stands for Statistical Process Control, a method used to monitor and control processes to ensure they are operating efficiently and within specifications.
SPC involves collecting and analyzing data to identify variations in a process
It helps in detecting and correcting issues before they result in defects
Common tools used in SPC include control charts, histograms, and Pareto charts
To configure a dp dp coupler, set the parameters for communication protocol, baud rate, address, and data format.
Set the communication protocol to match the devices being connected.
Configure the baud rate to ensure proper data transmission speed.
Assign a unique address to the dp dp coupler for identification.
Choose the appropriate data format for the connected devices.
Test the configuration to ensure proper communicati
I applied via Job Portal
SCADA can be configured by setting up communication protocols, defining data points, creating graphical interfaces, and configuring alarms.
Set up communication protocols such as Modbus, DNP3, or OPC to communicate with field devices
Define data points by specifying the tags for each device or sensor being monitored
Create graphical interfaces by designing screens that display real-time data in a user-friendly format
Confi...
I/O modules can be configured by setting up the input and output signals, assigning addresses, and configuring communication protocols.
Identify the type of I/O module being used (analog, digital, etc.)
Assign addresses to the input and output signals for communication
Configure the communication protocols such as Modbus, Profibus, etc.
Set up the parameters for data transmission and reception
Test the configured I/O module
Assigning an IP address involves configuring the network settings of a device to enable communication with other devices on the same network.
Access the network settings of the device
Choose a suitable IP address based on the network's subnet
Assign the IP address along with subnet mask and default gateway
Ensure no IP address conflicts with other devices on the network
Save the settings and test the connection
I applied via Campus Placement and was interviewed in Sep 2022. There was 1 interview round.
1 horsepower is equal to approximately 0.746 kilowatts.
1 horsepower (hp) is a unit of power commonly used in the field of engineering.
1 kilowatt (kW) is a unit of power commonly used in electrical systems.
To convert horsepower to kilowatts, multiply the horsepower value by 0.746.
For example, if you have 2 horsepower, it would be equal to 1.492 kilowatts.
based on 3 reviews
Rating in categories
Quality Engineer
180
salaries
| ₹1 L/yr - ₹6.5 L/yr |
Engineer
163
salaries
| ₹3.2 L/yr - ₹7.1 L/yr |
Production Engineer
156
salaries
| ₹1 L/yr - ₹7.6 L/yr |
Senior Engineer
150
salaries
| ₹4.2 L/yr - ₹10.2 L/yr |
Assistant Manager
90
salaries
| ₹6 L/yr - ₹14 L/yr |
Bosch
Ceat Tyres
UNO Minda
Apollo Tyres