I applied via Naukri.com and was interviewed in May 2024. There were 2 interview rounds.
Aptitude test in which they will ask you reasoning, aptitude and English
Bending moment diagram (BMD) for a simply supported beam with a point load at the center is a triangular shape.
BMD starts from zero at the supports and reaches maximum at the point load location.
The BMD then decreases back to zero at the other support.
The shape of the BMD is triangular in this case.
The maximum BMD value occurs at the point load location.
Fixed beam end moment for point load at center is half of the point load times the span length.
Fixed beam end moment for point load at center is calculated as half of the point load times the span length
This is applicable for a simply supported beam with a point load applied at the center
The formula for fixed beam end moment for point load at center is M = (wL^2)/8, where M is the moment, w is the point load, and L is
I applied via Campus Placement and was interviewed in Mar 2024. There was 1 interview round.
A portal frame is a type of structural frame commonly used in buildings and bridges.
Consists of vertical columns and horizontal beams connected together to form a rigid structure
Provides lateral stability to the building or bridge
Commonly used in industrial buildings, warehouses, and agricultural structures
Bar bending diagram shows the shape of a reinforced concrete bar after bending, while shear force diagram shows the variation of shear force along the length of a beam.
Bar bending diagram displays the shape of a bar after bending to show the location and extent of bends.
Shear force diagram shows the variation of shear force along the length of a beam, typically in a graphical form.
Both diagrams are important in structu...
IS code refers to Indian Standard code used in structural engineering.
IS 456:2000 - Code of practice for plain and reinforced concrete
IS 800:2007 - General construction in steel
IS 3370:1965 - Code of practice for concrete structures for storage of liquids
I applied via Walk-in and was interviewed in Aug 2023. There was 1 interview round.
Effective length is a measure used in structural engineering to determine the stability and strength of a member.
Effective length is the distance between points of zero moment in a structural member.
It is used to calculate the buckling capacity of columns and beams.
The effective length factor depends on the end conditions of the member.
For example, a simply supported beam has an effective length factor of 1, while a fi...
based on 2 reviews
Rating in categories
Senior Engineer
5.3k
salaries
| ₹5 L/yr - ₹17 L/yr |
Engineer
4.7k
salaries
| ₹3 L/yr - ₹8.2 L/yr |
Technical Lead
2k
salaries
| ₹8.5 L/yr - ₹28 L/yr |
Project Lead
1.6k
salaries
| ₹6 L/yr - ₹22.1 L/yr |
Senior Software Engineer
1.4k
salaries
| ₹4.8 L/yr - ₹18.2 L/yr |
TCS
Infosys
Wipro
Tech Mahindra