Steel sections are structural shapes made from steel for construction purposes.
I-beams
H-beams
C-channels
Angle sections
T-sections
Z-sections
Box sections
Circular sections
Different types of loads applied on long and short steel columns
Long columns are more susceptible to buckling under compressive loads
Short columns are more susceptible to crushing under compressive loads
Long columns are more likely to experience bending under lateral loads
Short columns are more likely to experience shear under lateral loads
Examples of loads include dead load, live load, wind load, seismic load, etc.
I applied via Walk-in and was interviewed in Feb 2021. There were 3 interview rounds.
I applied via Recruitment Consultant and was interviewed in Mar 2021. There were 3 interview rounds.
I applied via Campus Placement and was interviewed before Jul 2021. There were 3 interview rounds.
Aptitude test consists the MCQ's in which test our GK , reasonability and logics
Latent heat is the heat absorbed or released by a substance during a phase change without a change in temperature.
Latent heat is the energy required to change the state of a substance without changing its temperature.
It is the heat absorbed or released during a phase change.
Latent heat is important in processes such as melting, freezing, vaporization, and condensation.
Examples include the heat absorbed by ice to melt i...
posted on 25 Dec 2023
I applied via Recruitment Consulltant and was interviewed before Dec 2022. There were 2 interview rounds.
Motor megger value should be at least twice the rated voltage of the motor. Cable size should be selected based on the full load current of the motor.
Motor megger value should be at least 2 times the rated voltage of the motor to ensure insulation integrity.
Cable size should be selected based on the full load current of the motor to prevent overheating and voltage drop.
For example, for a motor rated at 400V, the megger...
OLR value of a motor is determined by the rating of the motor and the MPCB rating.
OLR value is the Overload Relay value, which is used to protect the motor from overload conditions.
The OLR value is typically set based on the rating of the motor and the rating of the Motor Protection Circuit Breaker (MPCB).
For example, if a motor has a rating of 5 HP and the MPCB rating is 10A, the OLR value would be calculated accordin
based on 1 review
Rating in categories
Assistant Manager
2.3k
salaries
| ₹4.4 L/yr - ₹13.6 L/yr |
Junior Engineer
1k
salaries
| ₹1.8 L/yr - ₹5.6 L/yr |
Deputy Manager
989
salaries
| ₹5.7 L/yr - ₹18.4 L/yr |
Assistant Engineer
831
salaries
| ₹2.4 L/yr - ₹8.5 L/yr |
Manager
623
salaries
| ₹9 L/yr - ₹24.2 L/yr |
Tata Steel
JSW Steel
ArcelorMittal Nippon Steel
Jindal Stainless