MCB and overload relay are both electrical protection devices, but they serve different purposes.
MCB stands for Miniature Circuit Breaker and is used to protect electrical circuits from overcurrents and short circuits.
Overload relay is used to protect motors and other electrical equipment from excessive current that can cause overheating and damage.
MCB operates based on the principle of thermal and magnetic tripping, w...
A soft starter is a device used to gradually start and stop the motor by controlling the voltage applied to it.
Soft starters are used to reduce the starting current and torque of an electric motor.
They provide a smooth and controlled acceleration and deceleration of the motor.
Soft starters can be used in various applications such as pumps, fans, and conveyor belts.
They typically consist of power electronics, control ci...
A drive is a device that reads and writes data to storage media, allowing users to access and store information.
Drives can be internal or external, such as hard disk drives (HDDs) or solid-state drives (SSDs).
They use various technologies like magnetic or flash memory to store data.
Drives are connected to a computer or device through interfaces like SATA, USB, or PCIe.
They have controllers that manage data transfer and...
Star delta starters are used to reduce the starting current of induction motors.
Star delta starters are used in applications where the starting current needs to be limited.
They are commonly used in industries where large motors are employed.
By starting the motor in star configuration, the current is reduced to one-third of the delta configuration.
This helps in preventing excessive voltage drop and reduces stress on the...
The protection of a transformer involves various measures to ensure its safe and reliable operation.
Overcurrent protection: Protects against excessive current flow.
Overvoltage protection: Guards against high voltage surges.
Under/over frequency protection: Monitors and controls the frequency of the input power.
Temperature protection: Prevents overheating by monitoring the transformer's temperature.
Buchholz relay protect...
posted on 25 Dec 2023
I applied via Recruitment Consulltant and was interviewed before Dec 2022. There were 2 interview rounds.
Motor megger value should be at least twice the rated voltage of the motor. Cable size should be selected based on the full load current of the motor.
Motor megger value should be at least 2 times the rated voltage of the motor to ensure insulation integrity.
Cable size should be selected based on the full load current of the motor to prevent overheating and voltage drop.
For example, for a motor rated at 400V, the megger...
OLR value of a motor is determined by the rating of the motor and the MPCB rating.
OLR value is the Overload Relay value, which is used to protect the motor from overload conditions.
The OLR value is typically set based on the rating of the motor and the rating of the Motor Protection Circuit Breaker (MPCB).
For example, if a motor has a rating of 5 HP and the MPCB rating is 10A, the OLR value would be calculated accordin
posted on 18 Jun 2024
Dynamic viscosity is a measure of a fluid's resistance to flow under applied force.
Dynamic viscosity is also known as absolute viscosity.
It is a measure of how thick or thin a fluid is.
Units of dynamic viscosity are Pascal-seconds (Pa·s) or Poise (P).
Water has a dynamic viscosity of about 0.001 Pa·s at room temperature.
The stress-strain diagram shows the relationship between stress and strain in a material.
The stress-strain diagram typically consists of a linear elastic region, a yield point, and a plastic deformation region.
The slope of the linear elastic region represents the material's Young's Modulus.
The yield point indicates the stress at which the material begins to deform plastically.
The ultimate tensile strength is the maximu...
I applied via Walk-in and was interviewed before Nov 2022. There were 2 interview rounds.
FMEA is Failure Modes and Effects Analysis used to identify and prioritize potential failures in a process or product.
FMEA involves identifying potential failure modes, their effects, and the likelihood of their occurrence.
To improve a control plan using FMEA, prioritize high-risk failure modes and implement controls to prevent or mitigate them.
Regularly review and update the FMEA and control plan based on new informat...
Failure Mode and Effects Analysis
FMEA stands for Failure Mode and Effects Analysis
It is a systematic method for identifying and preventing potential failures in a design or process
Helps in prioritizing and addressing potential failure modes based on their impact and likelihood
Commonly used in industries such as automotive, aerospace, and manufacturing
Example: Conducting FMEA on a car engine to identify potential failur
5S is a methodology used to organize a workplace for efficiency and effectiveness by sorting, setting in order, shining, standardizing, and sustaining.
Sort - Remove unnecessary items from the workplace.
Set in order - Organize remaining items in a logical manner.
Shine - Clean and inspect the workplace regularly.
Standardize - Establish standards and procedures for maintaining the workplace.
Sustain - Ensure the 5S system ...
To find the error in root cause, analyze the situation, gather data, identify potential causes, and test hypotheses.
Analyze the situation thoroughly to understand the context of the error.
Gather data from various sources to identify patterns or anomalies.
Identify potential causes by brainstorming and using tools like fishbone diagrams or 5 Whys.
Test hypotheses by conducting experiments or simulations to validate the ro...
posted on 28 Jul 2023
I applied via Walk-in and was interviewed before Jul 2022. There were 3 interview rounds.
I applied via Walk-in and was interviewed in Aug 2023. There was 1 interview round.
MCB and overload relay are both electrical protection devices, but they serve different purposes.
MCB stands for Miniature Circuit Breaker and is used to protect electrical circuits from overcurrents and short circuits.
Overload relay is used to protect motors and other electrical equipment from excessive current that can cause overheating and damage.
MCB operates based on the principle of thermal and magnetic tripping, w...
A soft starter is a device used to gradually start and stop the motor by controlling the voltage applied to it.
Soft starters are used to reduce the starting current and torque of an electric motor.
They provide a smooth and controlled acceleration and deceleration of the motor.
Soft starters can be used in various applications such as pumps, fans, and conveyor belts.
They typically consist of power electronics, control ci...
A drive is a device that reads and writes data to storage media, allowing users to access and store information.
Drives can be internal or external, such as hard disk drives (HDDs) or solid-state drives (SSDs).
They use various technologies like magnetic or flash memory to store data.
Drives are connected to a computer or device through interfaces like SATA, USB, or PCIe.
They have controllers that manage data transfer and...
Star delta starters are used to reduce the starting current of induction motors.
Star delta starters are used in applications where the starting current needs to be limited.
They are commonly used in industries where large motors are employed.
By starting the motor in star configuration, the current is reduced to one-third of the delta configuration.
This helps in preventing excessive voltage drop and reduces stress on the...
The protection of a transformer involves various measures to ensure its safe and reliable operation.
Overcurrent protection: Protects against excessive current flow.
Overvoltage protection: Guards against high voltage surges.
Under/over frequency protection: Monitors and controls the frequency of the input power.
Temperature protection: Prevents overheating by monitoring the transformer's temperature.
Buchholz relay protect...
I applied via Referral and was interviewed before Feb 2023. There was 1 interview round.
posted on 25 Dec 2023
I applied via Recruitment Consulltant and was interviewed before Dec 2022. There were 2 interview rounds.
Motor megger value should be at least twice the rated voltage of the motor. Cable size should be selected based on the full load current of the motor.
Motor megger value should be at least 2 times the rated voltage of the motor to ensure insulation integrity.
Cable size should be selected based on the full load current of the motor to prevent overheating and voltage drop.
For example, for a motor rated at 400V, the megger...
OLR value of a motor is determined by the rating of the motor and the MPCB rating.
OLR value is the Overload Relay value, which is used to protect the motor from overload conditions.
The OLR value is typically set based on the rating of the motor and the rating of the Motor Protection Circuit Breaker (MPCB).
For example, if a motor has a rating of 5 HP and the MPCB rating is 10A, the OLR value would be calculated accordin
based on 2 reviews
Rating in categories
Associate Manager
31
salaries
| ₹5.4 L/yr - ₹12.5 L/yr |
Executive
26
salaries
| ₹3 L/yr - ₹10 L/yr |
Quality Engineer
18
salaries
| ₹2.1 L/yr - ₹4.8 L/yr |
Manager
11
salaries
| ₹9.9 L/yr - ₹14.4 L/yr |
Quality Inspector
10
salaries
| ₹1.8 L/yr - ₹3.2 L/yr |
Tata Steel
JSW Steel
Steel Authority Of India
ArcelorMittal Nippon Steel