Filter interviews by
Clear (1)
I was interviewed in Jan 2024.
Power factor is the ratio of real power to apparent power in an AC circuit. VFD stands for Variable Frequency Drive. AC motors run on alternating current while DC motors run on direct current.
Power factor is a measure of how effectively electrical power is being used in a circuit.
It is calculated by dividing the real power (in watts) by the apparent power (in volt-amperes).
A power factor of 1 indicates that all the pow...
Types of load cells include strain gauge load cells, hydraulic load cells, and capacitive load cells.
Strain gauge load cells measure the strain or deformation of a material.
Hydraulic load cells use hydraulic fluid to measure force.
Capacitive load cells measure changes in capacitance to determine force.
Other types of load cells include piezoelectric load cells and pneumatic load cells.
I applied via Referral and was interviewed before May 2023. There were 3 interview rounds.
MCQ Question of total 10 question
Reverse arc flashing on ACB breaker refers to the phenomenon where the arc flash occurs on the opposite side of the contacts during the opening operation.
Reverse arc flashing happens when the arc flash occurs on the side of the contacts opposite to the normal direction during the opening operation of the ACB breaker.
This phenomenon can be caused by factors such as high fault currents, improper maintenance, or inadequat...
Top trending discussions
posted on 29 Nov 2022
I applied via Walk-in and was interviewed in May 2022. There was 1 interview round.
The capacity of a furnace refers to its heating output, typically measured in BTUs or tons.
Furnace capacity is determined by the amount of heat it can produce.
It is usually measured in BTUs (British Thermal Units) or tons.
Higher capacity furnaces can produce more heat and are suitable for larger spaces.
For example, a furnace with a capacity of 80,000 BTUs can heat a larger area compared to one with a capacity of 40,000
Drive components in CCM department are the parts that enable the motor to function properly.
Drive components include motors, gears, belts, and pulleys.
They work together to transfer power from the motor to the machine.
The components must be properly sized and aligned to ensure efficient operation.
Examples of machines that use drive components include conveyor belts, pumps, and fans.
I applied via Approached by Company and was interviewed in Apr 2022. There were 3 interview rounds.
All machine are maintenance and connection and operated.
All starter are maintenance
All machine are repair.
I applied via Walk-in and was interviewed in Apr 2022. There were 2 interview rounds.
Transformer parts include core, windings, insulation, tap changer, and cooling system.
Core: magnetic material that provides a path for the magnetic flux
Windings: conductors that carry the electrical current
Insulation: material that separates the windings and core to prevent short circuits
Tap changer: device that adjusts the number of turns in the windings to regulate voltage
Cooling system: dissipates heat generated by ...
Transformer nameplate details include manufacturer, model, kVA rating, voltage rating, frequency, and serial number.
Manufacturer name
Model number
kVA rating
Voltage rating
Frequency
Serial number
The minimum insulation resistance value for a Lt Motor.
The minimum insulation resistance value for a Lt Motor is typically 1 Megaohm.
This value is important to ensure the motor is properly insulated and protected from electrical faults.
Insulation resistance can be measured using a megohmmeter.
Factors that can affect insulation resistance include temperature, humidity, and contamination.
Regular testing of insulation res...
Minimum insulation resistance value for HT motor.
HT motor insulation resistance should be at least 1 Mega Ohm
Insulation resistance should be measured regularly to ensure safety
Factors like temperature and humidity can affect insulation resistance
I applied via Company Website and was interviewed in May 2023. There were 4 interview rounds.
Electrical related questions. And genaral electrical engineer questions
All about technical interview and ask only your fields related questions.
I applied via Company Website and was interviewed in Apr 2024. There was 1 interview round.
PLC stands for Programmable Logic Controller, used in industrial automation to control machinery and processes.
PLC is a digital computer used for automation of electromechanical processes.
It uses a programmable memory to store instructions and specific functions.
PLCs are commonly used in manufacturing plants, assembly lines, and other industrial settings.
They can be programmed using ladder logic, function block diagram...
Different types of communication cables used in the electrical engineering industry include coaxial cables, twisted pair cables, and fiber optic cables.
Coaxial cables: used for high-frequency transmission and commonly used in cable television and computer networks.
Twisted pair cables: consists of pairs of insulated copper wires twisted together to reduce electromagnetic interference, commonly used in Ethernet networks.
...
Single mode fiber optic cable has a smaller core size and allows only one mode of light to propagate, while multimode fiber optic cable has a larger core size and allows multiple modes of light to propagate.
Single mode fiber optic cable has a core size of 8-10 microns, while multimode fiber optic cable has a core size of 50-62.5 microns.
Single mode fiber optic cable provides higher bandwidth and longer transmission dis...
Types of transformers include step-up, step-down, isolation, autotransformer, and distribution transformers.
Step-up transformer increases voltage output
Step-down transformer decreases voltage output
Isolation transformer provides electrical isolation between primary and secondary windings
Autotransformer has a single winding with multiple taps for different voltage levels
Distribution transformer is used to distribute pow
Protection system for transformers includes Buchholz relay, differential protection, overcurrent protection, and temperature monitoring.
Buchholz relay detects internal faults like gas accumulation or oil leakage
Differential protection compares currents entering and leaving the transformer to detect faults
Overcurrent protection safeguards against excessive current flow
Temperature monitoring ensures the transformer opera
Regular maintenance of transformers and motors is crucial for ensuring optimal performance and preventing breakdowns.
Regularly inspecting for signs of wear and tear
Checking and replacing worn out parts such as brushes and bearings
Testing insulation resistance
Cleaning and lubricating moving parts
Monitoring temperature and vibration levels
Following manufacturer's maintenance guidelines
Keeping records of maintenance activ
Differential protection of transformer ensures that any internal fault is quickly detected and isolated to prevent damage.
Differential protection compares the current entering and leaving the transformer windings. If there is a difference, it indicates a fault.
The relay used for differential protection operates when the difference in current exceeds a set threshold.
This protection scheme is effective in detecting inter...
Ten delta test is a method used to determine the phase relationship between the primary and secondary windings of a transformer.
Ten delta test involves injecting a low voltage signal into the primary winding and measuring the corresponding output in the secondary winding.
The test helps in identifying any phase shift or angular displacement between the primary and secondary windings.
It is important for ensuring the prop...
I applied via Company Website and was interviewed in Apr 2024. There was 1 interview round.
posted on 6 Aug 2023
The question is about solving an electrical problem.
Identify the specific electrical problem being described
Analyze the circuit or system to determine the root cause of the issue
Propose potential solutions or troubleshooting steps to resolve the problem
Problem solved on Electrical Equipment
I applied via LinkedIn and was interviewed in Aug 2024. There was 1 interview round.
based on 3 interviews
Interview experience
based on 11 reviews
Rating in categories
Junior Engineer
150
salaries
| ₹0 L/yr - ₹0 L/yr |
Engineer
122
salaries
| ₹0 L/yr - ₹0 L/yr |
Junior Manager
122
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Engineer
96
salaries
| ₹0 L/yr - ₹0 L/yr |
Associate Manager
76
salaries
| ₹0 L/yr - ₹0 L/yr |
Tata Steel
JSW Steel
Steel Authority Of India
Vedanta Limited