Documents required for installation of a flow meter
Manufacturer's installation manual
Piping and instrumentation diagram (P&ID)
Electrical wiring diagram
Calibration certificate
Material test certificate (MTC) for piping
Safety data sheet (SDS) for chemicals used in installation
Permit for installation
Quality assurance plan (QAP)
As-built drawings
posted on 17 Nov 2020
I applied via Company Website
I applied via Recruitment Consultant
posted on 16 Jun 2021
I applied via Campus Placement and was interviewed in Dec 2020. There were 3 interview rounds.
posted on 9 May 2021
I applied via Walk-in and was interviewed in Nov 2020. There were 4 interview rounds.
posted on 14 Jan 2022
I applied via Walk-in and was interviewed before Jan 2021. There were 3 interview rounds.
The least count of staff reading is the smallest measurement that can be read and recorded using the staff.
The least count is determined by the smallest division on the staff scale.
It is usually expressed in millimeters or centimeters.
For example, if the smallest division on the staff scale is 1 mm, then the least count is 1 mm.
The least count is important in accurately measuring and recording distances in civil engine
To draw SFD and BMD for simply supported beam under UDL of 10KM/m, follow these steps:
Calculate the reactions at the supports
Draw the SFD by taking the upward forces as positive and starting from one end
Draw the BMD by taking the positive moment as clockwise and starting from one end
Mark the maximum values of SFD and BMD
Check the equilibrium and compatibility of the beam
posted on 19 Aug 2021
I applied via Campus Placement and was interviewed before Aug 2020. There were 3 interview rounds.
Types of faults in transmission lines
Short circuit fault
Open circuit fault
Ground fault
Transient fault
Intermittent fault
Various types of protection used in generators, transformers, and grounding.
Generator protection includes overcurrent, differential, and reverse power protection.
Transformer protection includes overcurrent, differential, and Buchholz protection.
Grounding protection includes earth fault protection and lightning protection.
Other types of protection include overvoltage, underfrequency, and thermal protection.
Each type of ...
There are two types of distribution systems: radial and network.
Radial distribution system is a simple and common system where power flows in one direction from the source to the load.
Network distribution system is a complex system where power flows in multiple directions through interconnected feeders and transformers.
Radial system is suitable for areas with low power demand and less number of consumers.
Network system...
I have experience in rating generators and transformers from my internship at NALCO Captive Power Plant.
During my internship, I learned how to rate generators and transformers based on their capacity and efficiency.
I gained hands-on experience in using instruments to measure the performance of generators and transformers.
I also learned about the importance of regular maintenance and testing to ensure optimal performanc...
posted on 5 Oct 2020
posted on 1 Jan 2022
I applied via Campus Placement and was interviewed before Jan 2021. There were 4 interview rounds.
Design Engineer
276
salaries
| ₹5 L/yr - ₹18 L/yr |
Senior Design Engineer
147
salaries
| ₹9 L/yr - ₹26 L/yr |
Piping Design Engineer
101
salaries
| ₹4.7 L/yr - ₹15 L/yr |
Piping Designer
88
salaries
| ₹3.4 L/yr - ₹12.8 L/yr |
Senior Engineer
73
salaries
| ₹10 L/yr - ₹21 L/yr |
L&T Construction
Megha Engineering & Infrastructures
Shapoorji Pallonji Group
Alstom Transportation