Filter interviews by
I applied via Walk-in and was interviewed in Mar 2023. There were 2 interview rounds.
Civil construction management process involves planning, organizing, and controlling construction activities to ensure successful project completion.
Planning phase includes site investigation, feasibility study, and design development.
Organizing phase involves procurement of materials, equipment, and labor.
Controlling phase includes monitoring progress, quality control, and cost management.
Regular communication and coo...
I applied via Approached by Company and was interviewed in Aug 2023. There were 3 interview rounds.
Side planing ,and labour handling
Drowning reading ,
Group discussion ,planing work next day
And side working discussion
Top trending discussions
posted on 30 Nov 2023
I applied via Naukri.com and was interviewed in Oct 2023. There were 3 interview rounds.
Bar bending schedule , RL , BSS , HI, TBM, water rasiw, , BS
The thickness of DPC can be either 2.5cm or 1 inch.
DPC stands for Damp Proof Course, which is a layer of waterproof material used in construction to prevent moisture from rising through the walls or floors.
The thickness of DPC is typically determined based on the specific requirements of the project and local building codes.
In some regions, the thickness of DPC is specified in centimeters (e.g., 2.5cm), while in others...
The height of the window is 2.1m.
The height of the window is a fixed measurement.
It is important to consider the height of the window when designing the building.
The height of the window may vary depending on the specific requirements of the project.
The height of the building is 3.15m.
The height of the building is a crucial measurement in civil engineering.
It is important to accurately measure and document the height of a building for various purposes such as construction planning, structural analysis, and code compliance.
In this case, the height of the building is specified as 3.15m.
This measurement can be used to determine the number of floors, calculate the vol...
The lintel thickness is 15cm (inch).
The lintel thickness is the measurement of the horizontal beam that supports the load above an opening, such as a door or window.
A lintel with a thickness of 15cm (inch) is considered standard in many construction projects.
The thickness of the lintel is determined based on the span of the opening and the load it needs to support.
Lintels can be made of various materials, including con...
The weight of one bag of cement is 50 kg.
The weight of cement bags is standardized at 50 kg.
This weight is important for calculating the quantity of cement required for a project.
For example, if a project requires 100 bags of cement, the total weight would be 5000 kg.
RCC ,water ratio , bar bending schedule
The minimum thickness for a wall is typically 400 mm.
The minimum thickness of a wall is determined by structural requirements and building codes.
Thicker walls provide better structural stability and can support heavier loads.
The type of wall construction and materials used also influence the minimum thickness.
For example, a load-bearing concrete wall may require a minimum thickness of 400 mm to ensure structural integr...
The size of a concrete cube is typically 150mm x 150mm x 150mm for standard testing purposes.
Standard size for concrete cube is 150mm x 150mm x 150mm
Used for testing the compressive strength of concrete
Other sizes may be used for specific projects or requirements
posted on 31 Oct 2024
I applied via Naukri.com
Foundation footing requires a minimum cover of 50mm to 75mm for reinforcement protection.
Minimum cover of 50mm to 75mm is required for foundation footing to protect the reinforcement from corrosion and provide adequate strength.
The cover requirement may vary based on the type of soil, environmental conditions, and structural design.
Proper cover ensures durability and stability of the foundation.
In some cases, additiona...
The cover required for shuttering column up to FFL depends on the type of concrete being used and the environmental conditions.
Cover required for shuttering column up to FFL typically ranges from 25mm to 50mm.
Factors such as type of concrete mix, exposure conditions, and structural requirements can influence the required cover.
For example, in harsh environmental conditions or high-strength concrete, a higher cover may ...
I applied via Naukri.com and was interviewed in Jul 2023. There were 3 interview rounds.
The slope of stairs refers to the angle at which the stairs are inclined, affecting safety and accessibility.
The slope of stairs is typically between 30-35 degrees for comfortable and safe use.
Building codes may dictate specific slope requirements for stairs to ensure safety and accessibility.
The slope of stairs can be calculated using trigonometry, with the rise and run of the stairs determining the angle.
A steep slop...
Covering is provided in steel reinforcement to protect it from corrosion and to ensure proper bond with concrete.
Covering protects steel reinforcement from corrosion caused by exposure to moisture and chemicals in the environment.
It helps in maintaining the bond between steel reinforcement and concrete, ensuring structural integrity.
Proper covering thickness is important to prevent rusting of steel bars and maintain du...
The leaping zone of steel reinforcement refers to the area where the steel bars are not provided in a concrete member.
The leaping zone is typically found in beams and slabs where the steel reinforcement is not required to be continuous.
It is important to ensure that the leaping zone does not compromise the structural integrity of the member.
Proper detailing and design considerations are necessary to determine the exten...
Site uses materials can be identified through visual inspection, testing, and documentation.
Conduct visual inspection of materials on site to identify their type and quality
Perform tests on materials such as soil, concrete, and asphalt to determine their properties
Review documentation such as material specifications, delivery receipts, and quality control reports
Consult with suppliers and manufacturers to verify the au
A section of stairs case with reinforcement is a structural drawing showing the details of the stairs and the reinforcement bars used for strength.
Include dimensions and materials used for the stairs and reinforcement bars
Show the arrangement of reinforcement bars in the section view
Label the different components of the stairs case for clarity
Maivan technology consists of various components including sensors, software, and data analytics for monitoring and managing civil infrastructure.
Sensors are used to collect data on various parameters such as temperature, humidity, and structural integrity.
Software is utilized to process the data collected by sensors and provide real-time monitoring and analysis.
Data analytics tools are employed to identify patterns, t...
I applied via Campus Placement and was interviewed in Mar 2024. There was 1 interview round.
posted on 13 Jul 2023
posted on 3 May 2023
I applied via Campus Placement and was interviewed in Apr 2023. There were 3 interview rounds.
I applied via Referral and was interviewed in Aug 2022. There were 2 interview rounds.
based on 2 interviews
Interview experience
Civil Site Engineer
221
salaries
| ₹2.2 L/yr - ₹8.6 L/yr |
Site Engineer
206
salaries
| ₹2.4 L/yr - ₹7 L/yr |
Quantity Surveyor
54
salaries
| ₹3 L/yr - ₹7.2 L/yr |
Senior Planning Engineer
53
salaries
| ₹5 L/yr - ₹8.6 L/yr |
Civil Engineer
48
salaries
| ₹2.4 L/yr - ₹7.5 L/yr |
Larsen & Toubro Limited
Tata Projects
Shapoorji Pallonji Group
GAMMON INDIA