Transformer types include step-up, step-down, isolation, autotransformer, and instrument transformer.
Step-up transformer increases voltage while decreasing current
Step-down transformer decreases voltage while increasing current
Isolation transformer separates primary and secondary windings
Autotransformer has a single winding with multiple taps for voltage adjustment
Instrument transformer is used for measuring current or
Motors are devices that convert electrical energy into mechanical energy. There are various types of motors.
DC motors: used in appliances, toys, and automobiles
AC motors: used in industrial machinery and household appliances
Stepper motors: used in robotics and automation
Servo motors: used in precision control applications
Brushless motors: used in drones and electric vehicles
posted on 14 Mar 2024
I applied via Approached by Company and was interviewed before Mar 2023. There were 3 interview rounds.
posted on 3 May 2022
I applied via Approached by Company and was interviewed in Nov 2021. There were 4 interview rounds.
To become a technical leader in software engineering, contributing to innovative projects and mentoring junior engineers.
To continuously enhance my technical skills and stay updated with the latest technologies.
To lead and deliver complex software projects successfully.
To mentor and guide junior engineers, fostering their growth and development.
To contribute to the development of innovative and impactful software solut...
Secure cloud deployments can be implemented through various measures such as encryption, access control, and regular security audits.
Implement encryption for data at rest and in transit
Use access control mechanisms to restrict unauthorized access
Regularly conduct security audits to identify and address vulnerabilities
Implement multi-factor authentication for added security
Ensure compliance with industry standards and r...
Check server logs, review code, test endpoints, and verify database connections.
Check server logs for error messages
Review code for syntax errors or logical mistakes
Test endpoints using tools like Postman or cURL
Verify database connections and credentials
Check for any recent changes or updates
Consider scaling issues or server overload
Consult with team members or experts if necessary
My next career goal is to become a technical lead and mentor junior engineers.
I want to take on more leadership responsibilities and guide a team towards success.
I plan to enhance my skills in project management and communication.
I aim to contribute to the growth and development of the organization.
I aspire to continuously learn and stay updated with the latest technologies and industry trends.
posted on 9 Apr 2021
I applied via Recruitment Consultant and was interviewed before Apr 2020. There were 4 interview rounds.
The power of a pump can be calculated using the formula: Power = (Flow rate x Head) / Efficiency
The power of a pump is determined by the flow rate, head, and efficiency
Flow rate is the volume of fluid passing through the pump per unit time
Head is the height difference between the inlet and outlet of the pump
Efficiency is the ratio of the actual power output to the power input
The formula to calculate power is: Power = (...
Air flow in HVAC ducting can be calculated using the formula Q = AV
Q = air flow rate in cubic feet per minute (CFM)
A = cross-sectional area of the duct in square feet
V = air velocity in feet per minute (FPM)
Air velocity can be measured using a pitot tube or an anemometer
Duct sizing and layout can affect air flow and should be considered in calculations
A reactor can be installed by following a few steps.
Choose a suitable location for the reactor
Prepare the foundation for the reactor
Install the reactor vessel and associated equipment
Connect the piping and electrical systems
Test the reactor for proper functioning
Commissioning of a reactor involves a series of tests and procedures to ensure safe and efficient operation.
Pre-commissioning checks and inspections
Functional testing of equipment and systems
Testing of safety systems
Fuel loading and reactor startup
Performance testing and optimization
Final acceptance testing
Documentation and training
Regulatory approval
Examples: Pressurized Water Reactor (PWR), Boiling Water Reactor (BWR
Condensers are used to convert high-pressure vapor into liquid form.
Condensers are used in various industries such as power plants, refrigeration systems, and chemical processing plants.
They help in increasing the efficiency of the system by reducing the pressure and temperature of the vapor.
They also help in recovering valuable materials from the vapor, such as water in a power plant.
Examples of condensers include she...
posted on 28 Nov 2024
I applied via campus placement at University of Reading and was interviewed in Oct 2024. There was 1 interview round.
I applied via Indeed and was interviewed in Nov 2023. There were 2 interview rounds.
The interview session took 30 minutes
Implement Java code to filter data from a list using Java Stream API
Use Stream.filter() method to filter data based on a given condition
Use lambda expressions to define the filtering condition
Collect the filtered data using Collectors.toList() method
based on 5 reviews
Rating in categories
Officer
775
salaries
| ₹1.6 L/yr - ₹5.7 L/yr |
Executive
763
salaries
| ₹1.8 L/yr - ₹8 L/yr |
Junior Officer
633
salaries
| ₹1.4 L/yr - ₹4 L/yr |
Chemist
624
salaries
| ₹1 L/yr - ₹4.4 L/yr |
Assistant Manager
573
salaries
| ₹4 L/yr - ₹13 L/yr |
Sun Pharmaceutical Industries
Cipla
DRJ & CO
Biocon Limited