i
Gps Renewables
Filter interviews by
I appeared for an interview in Dec 2023.
Designing equipment to remove gas and oil from the ground involves considering factors like extraction methods, safety measures, and environmental impact.
Consider different extraction methods such as drilling, hydraulic fracturing, or steam injection
Include safety measures like blowout preventers, emergency shutdown systems, and gas detection sensors
Address environmental impact by implementing measures to prevent spill...
I applied via Company Website and was interviewed in Mar 2024. There was 1 interview round.
Types of compressors include reciprocating, rotary, centrifugal, and scroll compressors.
Reciprocating compressors use pistons to compress air
Rotary compressors use rotating mechanisms like screws or vanes
Centrifugal compressors use a rotating impeller to create centrifugal force
Scroll compressors use two interleaving scrolls to compress air
Examples: Ingersoll Rand reciprocating compressor, Atlas Copco rotary compressor...
Top trending discussions
I applied via Recruitment Consultant and was interviewed before Jun 2019. There were 4 interview rounds.
I applied via Recruitment Consultant and was interviewed before Jun 2019. There were 3 interview rounds.
Answering questions related to confined space job, alignment of pump and motor, types of gaskets and valves, and troubleshooting reciprocating compressor.
Safety watch is responsible for monitoring the workers inside the confined space and ensuring their safety.
Alignment of pump and motor can be done using dial indicators or laser alignment tools.
Different types of gaskets include spiral wound, ring joint, and sheet gas...
I appeared for an interview in Oct 2019.
I applied via Company Website and was interviewed in Sep 2022. There were 4 interview rounds.
The qualification for an Instrumentation Technician typically includes a degree or diploma in instrumentation technology or a related field.
A degree or diploma in instrumentation technology or a related field is usually required.
Knowledge of electrical and electronic systems is important.
Experience with calibration and troubleshooting of instruments is often necessary.
Familiarity with industry standards and regulations...
Thermocouple range refers to the temperature range within which a thermocouple can accurately measure temperature.
Thermocouple range varies depending on the type of thermocouple used.
Common thermocouple types include J, K, T, E, and N.
For example, a type K thermocouple has a range of -200 to 1350 degrees Celsius.
It is important to select the appropriate thermocouple type for the temperature range being measured.
An anti-surge valve is a control valve used in a compressor system to prevent surge and maintain stable operation.
An anti-surge valve is typically installed in the discharge line of a compressor.
It is designed to protect the compressor from surge, which is a phenomenon of unstable flow and pressure that can cause damage to the compressor.
The valve opens or closes based on the compressor's operating conditions to mainta...
Yes, I have experience working with gas turbines.
I have worked with gas turbines in my previous job as an instrumentation technician.
I am familiar with the maintenance and troubleshooting of gas turbines.
I have experience in calibrating and testing gas turbine sensors and instruments.
I have knowledge of the safety protocols and regulations related to gas turbines.
There are three types of vibration in the field: axial, radial, and tangential.
Axial vibration occurs parallel to the axis of rotation.
Radial vibration occurs perpendicular to the axis of rotation.
Tangential vibration occurs at a right angle to both axial and radial vibration.
Vibration analysis is used to detect and diagnose problems in rotating machinery.
Excessive vibration can lead to premature failure of bearings, g
Yes, I am familiar with preventive maintenance jobs.
Preventive maintenance involves regularly scheduled inspections, cleaning, and repairs to prevent equipment breakdowns.
I have experience performing preventive maintenance on various types of instrumentation equipment, such as calibrators, transmitters, and controllers.
Examples of preventive maintenance tasks I have performed include checking for leaks, replacing worn ...
Precautions are necessary to ensure safe and efficient plant operation.
Regular maintenance of equipment and machinery
Proper training and certification of personnel
Strict adherence to safety protocols and procedures
Regular inspections and audits to identify potential hazards
Effective communication and coordination among team members
Use of personal protective equipment (PPE) as required
Emergency response planning and dri...
I am interested to work in maintenance field and troubleshooting
I applied via Recruitment Consulltant
CNG stands for Compressed Natural Gas.
CNG is a type of fuel that is used as an alternative to gasoline or diesel.
It is composed mainly of methane gas and is stored under high pressure.
CNG is commonly used in vehicles, especially in public transportation.
It is considered a cleaner and more environmentally friendly fuel compared to traditional fossil fuels.
CNG can be used in both spark-ignition and compression-ignition e
Preventive and corrective maintenance of various electrical equipment including breakers, motors, transformers, and relays.
Perform regular maintenance on high and low voltage breakers, motors, and transformers.
Test and calibrate various protection relays for motors, transformers, and generators.
Conduct transformer oil BDV test, thermal scanning, and earth fault and prediction tests.
Terminate high voltage motors, instal...
Preventive and corrective maintenance of various electrical equipment including breakers, motors, transformers, and relays.
Perform regular maintenance tasks on high and low voltage breakers, motors, and transformers.
Test and calibrate protection relays for motors, transformers, and generators.
Conduct transformer oil BDV tests, thermal scanning, and earth fault and prediction tests.
Terminate high voltage motors, install...
Preventive and corrective maintenance of various electrical equipment including breakers, motors, transformers, switches, relays, and testing/calibration of protections.
Preventive maintenance of H.V & LV breakers, motors, transformers, switches, etc.
Corrective maintenance of HV/MV/LV switchgears, breakers, cubicles, etc.
Testing and calibration of various protection relays for motors, transformers, generators.
Transforme...
based on 3 interviews
Interview experience
Assistant Manager
17
salaries
| ₹5.3 L/yr - ₹16 L/yr |
Senior Engineer
11
salaries
| ₹7.1 L/yr - ₹11.7 L/yr |
Project Manager
9
salaries
| ₹16.5 L/yr - ₹20.8 L/yr |
Mechanical Engineer
8
salaries
| ₹6 L/yr - ₹7.8 L/yr |
Project Coordinator
7
salaries
| ₹5.5 L/yr - ₹6.5 L/yr |
Petrofac
Baker Hughes
Cairn Energy
NBTC GROUP