Centrifugal pump works by converting mechanical energy from a motor into kinetic energy in the fluid being pumped.
Centrifugal pump uses a rotating impeller to create a centrifugal force that pushes the fluid towards the pump outlet.
The fluid enters the pump through the suction inlet and is accelerated by the impeller.
The kinetic energy of the fluid increases as it moves through the pump, resulting in an increase in pre...
Air conditioner works by absorbing heat from indoor air and releasing it outside, cooling the indoor space.
Air conditioner absorbs heat from indoor air using refrigerant
Refrigerant evaporates in the indoor coil, absorbing heat
The warm refrigerant gas is then pumped to the outdoor unit where it releases heat
The refrigerant condenses back into a liquid and the cycle repeats
The cooled air is then circulated back into the
Fermenter media can be prepared by following a few simple steps.
Select the appropriate ingredients based on the microorganism being cultured.
Mix the ingredients in the correct proportions and sterilize the media.
Inoculate the media with the microorganism and incubate under appropriate conditions.
Monitor the growth of the microorganism and adjust the media as necessary.
Harvest the desired product from the fermented medi
Genesys Biologics interview questions for popular designations
I applied via Walk-in and was interviewed before Apr 2023. There were 2 interview rounds.
Get interview-ready with Top Genesys Biologics Interview Questions
I applied via Referral and was interviewed in Aug 2021. There was 1 interview round.
Column efficiency can be evaluated by measuring the resolution, peak asymmetry, and plate count.
Resolution can be calculated by dividing the distance between two peaks by the sum of their peak widths.
Peak asymmetry can be determined by measuring the distance between the peak maximum and the point where the slope of the peak is half of the maximum slope.
Plate count can be calculated by dividing the column length by the
Ion exchange chromatography separates molecules based on their charge.
Ion exchange chromatography uses a resin with charged functional groups to attract and bind molecules with opposite charges.
The bound molecules can then be eluted by changing the pH or salt concentration of the solution.
This technique is commonly used in downstream processing to purify proteins and other biomolecules.
Examples of ion exchange resins i...
Packing and unpacking a column involves filling and emptying the column with the desired material.
Packing the column involves adding the desired material to the column and ensuring it is evenly distributed.
Unpacking the column involves removing the material from the column, usually by flushing it with a suitable solvent.
The packing material used depends on the type of column and the desired separation.
Common packing ma...
The chromatography software and version used is dependent on the specific process and equipment being utilized.
The software and version may vary depending on the manufacturer of the chromatography equipment.
Common chromatography software includes Unicorn, Chromeleon, and Empower.
The version used may also depend on the age of the equipment and compatibility with newer software.
The software is used to control the chromat
Flux in TFF refers to the rate of flow of the liquid through the membrane during filtration.
Flux is measured in volume per unit area per unit time.
It is influenced by factors such as pressure, temperature, and membrane pore size.
High flux rates can lead to membrane fouling and reduced filtration efficiency.
NWP stands for nominal molecular weight cut-off in TFF.
NWP is a parameter used in tangential flow filtration (TFF) to determine the size of molecules that can pass through the membrane.
It is the molecular weight at which 90% of the molecules are retained by the membrane.
NWP is important in downstream processing to ensure the desired molecules are separated from impurities.
For example, if the target molecule has a molec...
Column volume can be calculated by dividing the total bed volume by the packing factor.
Determine the total bed volume of the column
Calculate the packing factor of the column
Divide the total bed volume by the packing factor to get the column volume
Volumetric flow rate is the volume of fluid passing through a given point per unit time, while linear flow rate is the distance traveled by the fluid per unit time.
Volumetric flow rate is measured in units of volume per unit time, such as liters per minute or gallons per hour.
Linear flow rate is measured in units of distance per unit time, such as meters per second or feet per minute.
Volumetric flow rate is used to des...
I applied via Recruitment Consultant and was interviewed in Oct 2020. There were 3 interview rounds.
I applied via Company Website and was interviewed before Sep 2021. There were 2 interview rounds.
I am a highly motivated and experienced Research Associate seeking a challenging role. As for salary, I am expecting a competitive compensation package based on my qualifications and experience.
Experienced and motivated Research Associate
Seeking a challenging role
Expecting a competitive compensation package based on qualifications and experience
posted on 10 Jul 2017
I appeared for an interview before Jul 2016.
based on 7 interviews
Interview experience
based on 68 reviews
Rating in categories
Junior Executive
46
salaries
| ₹2.4 L/yr - ₹4.1 L/yr |
Executive
34
salaries
| ₹3.4 L/yr - ₹6.4 L/yr |
Senior Executive
26
salaries
| ₹5.2 L/yr - ₹8 L/yr |
Junior Research Associate
20
salaries
| ₹2.6 L/yr - ₹3.6 L/yr |
Assistant Manager
20
salaries
| ₹7.5 L/yr - ₹10 L/yr |
Biocon Limited
Bharat Biotech International
Serum Institute of India
Panacea Biotec