i
Crescon Projects & Services
Filter interviews by
I applied via Referral and was interviewed before Jul 2021. There were 2 interview rounds.
There are mainly four types of fire alarm systems: Conventional, Addressable, Analog, and Wireless.
Conventional fire alarm systems are the most basic and cost-effective systems.
Addressable fire alarm systems are more advanced and can pinpoint the exact location of the fire.
Analog fire alarm systems are similar to addressable systems but can also detect changes in the environment that may indicate a fire.
Wireless fire a...
Device coverages can be found by analyzing network coverage maps and conducting field tests.
Analyze network coverage maps provided by service providers
Conduct field tests to determine signal strength and coverage
Consider factors such as terrain, building materials, and weather conditions
Use specialized tools such as signal meters and spectrum analyzers
Consult with experts in the field for guidance and advice
Steps to follow before commissioning fire alarm panel
Ensure all devices are installed and wired correctly
Verify that the programming is correct and matches the building's layout
Perform a full system test to ensure all devices are communicating properly
Train building staff on how to operate the system and respond to alarms
Obtain necessary permits and approvals from local authorities
Ensure all documentation is complete a
Top trending discussions
I applied via Recruitment Consulltant and was interviewed in Sep 2024. There was 1 interview round.
Pump head loss calculation parameters include friction loss, elevation change, velocity head, and fittings.
Friction loss due to pipe roughness
Elevation change between inlet and outlet
Velocity head due to fluid velocity
Losses from fittings like elbows, tees, and valves
AHU components refer to the various parts of an Air Handling Unit that work together to regulate and circulate air in a building.
Filters - to remove dust and particles from the air
Coils - for heating or cooling the air
Fans - to circulate the air
Dampers - to control the flow of air
Humidifiers/dehumidifiers - to adjust the humidity levels
Centrifugal blowers are commonly used in AHUs for their efficiency and ability to handle high volumes of air.
Centrifugal blowers are preferred for AHUs due to their ability to handle high volumes of air efficiently.
They are more energy efficient compared to other types of blowers.
Examples of centrifugal blowers commonly used in AHUs include forward curved, backward inclined, and airfoil designs.
Primary pump is the main pump responsible for the majority of the pumping work, while secondary pump is a backup pump used in case the primary pump fails.
Primary pump is the main pump in a system, while secondary pump is a backup pump.
Primary pump is responsible for the majority of the pumping work, while secondary pump is used only when needed.
Examples: In a heating system, the primary pump circulates hot water throug...
AHU valve connection refers to the connection of valves in an air handling unit for controlling the flow of air.
AHU valve connection is essential for regulating the flow of air in an air handling unit.
Valves are typically connected to the AHU ductwork to control the amount of air entering or exiting the unit.
Properly connected valves ensure efficient operation of the AHU system.
Examples of AHU valves include damper val
Chilled water pipe size requirements depend on flow rate, pressure drop, material, insulation, and system design.
Flow rate: Determine the required flow rate of chilled water in the system.
Pressure drop: Calculate the pressure drop to ensure efficient operation.
Material: Select appropriate pipe material based on temperature and pressure requirements.
Insulation: Insulate the pipes to prevent heat gain or loss.
System desi...
The chiller connection refers to the method by which a chiller unit is connected to a building's HVAC system.
Chiller connection typically involves piping to transport chilled water from the chiller to the building's air handling units.
The connection may also include electrical wiring for power supply and control signals.
Proper chiller connection is crucial for efficient cooling and proper functioning of the HVAC system
Cracks in beams typically develop at locations of high stress concentrations or due to external factors like corrosion.
Cracks can develop at the supports of the beam where the bending moment is highest.
Cracks can also form at locations where there are changes in cross-section or material properties.
External factors like corrosion can lead to cracks in beams over time.
Cracks may also develop at locations where there are...
Different types of slab concrete testing include slump test, air content test, compressive strength test, and flexural strength test.
Slump test measures the consistency and workability of concrete.
Air content test determines the amount of air trapped in the concrete mixture.
Compressive strength test assesses the ability of concrete to withstand loads.
Flexural strength test evaluates the bending strength of concrete.
posted on 7 May 2024
I applied via LinkedIn and was interviewed in Apr 2024. There were 3 interview rounds.
I applied via Job Portal and was interviewed in Jun 2024. There were 2 interview rounds.
Make a some question.
Discus with condidate for how to handle a challenge at site level
posted on 28 Dec 2023
I applied via Approached by Company and was interviewed in Jul 2023. There were 4 interview rounds.
The current market labour rate and material price can vary depending on location, demand, and supply.
Labour rates can be influenced by factors such as skill level, experience, and union agreements.
Material prices can fluctuate due to changes in raw material costs, transportation expenses, and market demand.
It is important to regularly monitor market trends and industry news to stay informed about labour rates and mater
posted on 22 Nov 2022
Details about work responsibilities and Work experience improvement
I have achieved significant milestones in my career as a Project Engineer.
Successfully completed a complex construction project within the given timeline and budget.
Implemented innovative strategies to improve project efficiency and reduce costs.
Received recognition for outstanding problem-solving skills and ability to handle challenging situations.
Led a team of engineers and technicians to successfully deliver multipl...
I applied via Referral and was interviewed before Mar 2023. There was 1 interview round.
The project lifecycle is the series of phases a project goes through from initiation to completion.
Initiation: Define project goals, scope, and stakeholders
Planning: Create a detailed project plan, schedule, and budget
Execution: Implement the project plan and deliver the project
Monitoring and Controlling: Track progress, manage changes, and ensure quality
Closing: Finalize all project activities and hand off deliverable
Model reviews typically include checking for accuracy, completeness, consistency, and compliance with standards.
Checking accuracy of dimensions and specifications
Ensuring completeness of all required components and features
Verifying consistency in design and documentation
Confirming compliance with industry standards and regulations
The typical deliverables of a project engineer include design drawings, technical specifications, project schedules, cost estimates, and progress reports.
Design drawings: detailed plans and schematics for construction or manufacturing
Technical specifications: detailed requirements for materials, equipment, and processes
Project schedules: timelines for completing tasks and milestones
Cost estimates: budget projections fo...
I applied via Referral and was interviewed in May 2022. There was 1 interview round.
Project Engineer
20
salaries
| ₹3.5 L/yr - ₹6.5 L/yr |
QA QC Engineer
16
salaries
| ₹2 L/yr - ₹6 L/yr |
Safety Officer
14
salaries
| ₹2.9 L/yr - ₹4.6 L/yr |
HR Executive
9
salaries
| ₹2 L/yr - ₹4 L/yr |
Senior Project Engineer
7
salaries
| ₹5.8 L/yr - ₹7.5 L/yr |
Larsen & Toubro Limited
TCS
Hindustan Construction Company
GMR Group