Filter interviews by
I applied via Naukri.com and was interviewed in Oct 2022.Ā There were 2 interview rounds.
As a Senior Manager Quality Assurance for Aerospace BU, my role would be to ensure compliance with industry standards and regulations.
Develop and implement quality assurance policies and procedures
Ensure compliance with industry standards and regulations
Manage and lead a team of quality assurance professionals
Collaborate with cross-functional teams to identify and resolve quality issues
Conduct audits and assessments to...
Top trending discussions
posted on 2 Apr 2021
I applied via Naukri.com and was interviewed in Oct 2020.Ā There were 3 interview rounds.
posted on 5 Apr 2015
A saturation curve shows the relationship between the concentration of a substance and its ability to bind to a receptor.
The curve starts at zero binding when there is no substance present.
As the concentration of the substance increases, more receptors become occupied and the binding increases.
Eventually, all the receptors become occupied and the binding reaches a maximum, which is the saturation point.
Further increase...
Yes, entropy can be measured using instruments such as calorimeters and thermometers.
Entropy can be measured indirectly through changes in temperature or heat flow.
Calorimeters can measure the heat released or absorbed during a reaction, which can be used to calculate entropy.
Thermometers can measure changes in temperature, which can also be used to calculate entropy.
Entropy can also be estimated using statistical meth...
Heat is the transfer of energy from one body to another due to a temperature difference. Entropy is a measure of disorder or randomness.
Heat is a form of energy that flows from hotter to cooler objects
Entropy is a measure of the number of ways in which the energy of a system can be distributed among its particles
Heat can be transferred through conduction, convection, and radiation
Entropy always increases in a closed sy...
Yes, I am interested in pursuing higher studies.
I believe that higher education can provide me with more opportunities for personal and professional growth.
I am considering pursuing a master's degree in my field of work.
I have already started researching different programs and universities.
I am also exploring options for scholarships and financial aid.
I am excited about the prospect of continuing my education and expan
posted on 25 Feb 2015
I applied via Referral and was interviewed in Apr 2018.Ā There were 2 interview rounds.
I applied via Naukri.com and was interviewed in May 2019.Ā There was 1 interview round.
Answers to questions related to DOE, JH pillar, 5S, and IAFT 16949 vs TS16949
DOE stands for Design of Experiments and is a statistical tool used to optimize processes
Full factorial design is a DOE technique where all possible combinations of factors and levels are tested
Taguchi method is a DOE technique that focuses on reducing variability and improving quality
P-value is a statistical measure that helps determine the s...
posted on 4 Feb 2021
I applied via Recruitment Consultant and was interviewed before Feb 2020.Ā There were 4 interview rounds.
I applied via Company Website and was interviewed in May 2019.Ā There were 4 interview rounds.
There are several types of valves in instrumentation.
Gate valve
Ball valve
Butterfly valve
Globe valve
Check valve
Diaphragm valve
Needle valve
Plug valve
Pressure relief valve
Safety valve
PT, LT and LVDT are types of sensors used in engineering for measuring pressure, temperature and displacement respectively.
PT stands for Pressure Transducer and is used to measure pressure in various applications such as hydraulic systems, engines, and pipelines.
LT stands for Linear Transducer and is used to measure temperature in various applications such as engines, HVAC systems, and industrial processes.
LVDT stands ...
Calibration of I/P converter involves adjusting the output pressure to match the input signal.
Connect the I/P converter to a pressure source and a signal generator
Adjust the input signal to the desired value
Measure the output pressure and adjust it to match the input signal
Repeat the process at different input signal levels to ensure accuracy
Document the calibration results for future reference
A load cell is a transducer that converts force into an electrical signal. Calibration involves applying known loads and adjusting the output signal.
Load cell measures force or weight
It converts the force into an electrical signal
Calibration involves applying known loads and adjusting the output signal
Calibration can be done using a calibration machine or weights
Calibration should be done regularly to ensure accurate r
I applied via Campus Placement and was interviewed before Feb 2020.Ā There were 3 interview rounds.
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Assistant Manager
565
salaries
| ā¹3.5 L/yr - ā¹12 L/yr |
Deputy Manager
291
salaries
| ā¹6.6 L/yr - ā¹15 L/yr |
Engineer
284
salaries
| ā¹2 L/yr - ā¹8 L/yr |
Quality Engineer
159
salaries
| ā¹1.5 L/yr - ā¹6.8 L/yr |
Production Engineer
142
salaries
| ā¹1.5 L/yr - ā¹6.5 L/yr |
JBM Group
Subros
Ceat Tyres
UNO Minda