As an Electrical Shift Engineer, my roles and responsibilities include ensuring the smooth operation of electrical systems, troubleshooting issues, conducting maintenance, and overseeing a team of technicians.
Ensure the smooth operation of electrical systems
Troubleshoot electrical issues
Conduct maintenance on electrical equipment
Oversee a team of technicians
Develop and implement maintenance procedures
Ensure compliance ...
I am a dedicated and experienced Electrical Shift Engineer with a strong background in troubleshooting and maintenance of electrical systems.
I have a Bachelor's degree in Electrical Engineering from XYZ University.
I have 5+ years of experience working in industrial settings, ensuring smooth operation of electrical equipment.
I am proficient in PLC programming and have successfully implemented automation solutions to imp...
I am a dedicated and experienced Electrical Shift Engineer with a strong background in troubleshooting and maintenance of electrical systems.
Bachelor's degree in Electrical Engineering
5+ years of experience in electrical maintenance and troubleshooting
Proficient in PLC programming and control systems
Skilled in reading and interpreting electrical schematics
Experience with preventive maintenance programs
Seeking new challenges and opportunities for growth in a dynamic work environment.
Looking for opportunities to expand my skill set
Seeking a more challenging role
Interested in working in a different industry or with new technologies
I applied via Naukri.com and was interviewed before Jun 2022. There were 3 interview rounds.
What people are saying about ArcelorMittal Nippon Steel
I applied via Naukri.com and was interviewed in Nov 2023. There were 2 interview rounds.
My current salary is $50,000 per year. I am looking to change jobs for career growth and new challenges.
Current salary is $50,000 per year
Seeking career growth and new challenges
Opportunity for advancement in new role
I was interviewed in Jan 2024.
Power factor is the ratio of real power to apparent power in an AC circuit. VFD stands for Variable Frequency Drive. AC motors run on alternating current while DC motors run on direct current.
Power factor is a measure of how effectively electrical power is being used in a circuit.
It is calculated by dividing the real power (in watts) by the apparent power (in volt-amperes).
A power factor of 1 indicates that all the pow...
Types of load cells include strain gauge load cells, hydraulic load cells, and capacitive load cells.
Strain gauge load cells measure the strain or deformation of a material.
Hydraulic load cells use hydraulic fluid to measure force.
Capacitive load cells measure changes in capacitance to determine force.
Other types of load cells include piezoelectric load cells and pneumatic load cells.
posted on 10 Feb 2024
I applied via Walk-in and was interviewed in Jan 2023. There were 2 interview rounds.
Starters are used to control the starting and stopping of motors. Different types of starters are used based on the motor's power rating and application.
Direct On-Line (DOL) Starter
Star-Delta Starter
Auto Transformer Starter
Soft Starter
Variable Frequency Drive (VFD) Starter
Parallel operation of transformers refers to connecting two or more transformers with the same voltage ratio and frequency to supply a common load.
Parallel operation increases the capacity of the system and provides redundancy.
The transformers must have the same voltage ratio, impedance, and phase angle.
Proper synchronization is necessary to avoid circulating currents.
Parallel operation can be achieved by using a commo...
I applied via Walk-in and was interviewed in Apr 2022. There were 2 interview rounds.
Transformer parts include core, windings, insulation, tap changer, and cooling system.
Core: magnetic material that provides a path for the magnetic flux
Windings: conductors that carry the electrical current
Insulation: material that separates the windings and core to prevent short circuits
Tap changer: device that adjusts the number of turns in the windings to regulate voltage
Cooling system: dissipates heat generated by ...
Transformer nameplate details include manufacturer, model, kVA rating, voltage rating, frequency, and serial number.
Manufacturer name
Model number
kVA rating
Voltage rating
Frequency
Serial number
The minimum insulation resistance value for a Lt Motor.
The minimum insulation resistance value for a Lt Motor is typically 1 Megaohm.
This value is important to ensure the motor is properly insulated and protected from electrical faults.
Insulation resistance can be measured using a megohmmeter.
Factors that can affect insulation resistance include temperature, humidity, and contamination.
Regular testing of insulation res...
Minimum insulation resistance value for HT motor.
HT motor insulation resistance should be at least 1 Mega Ohm
Insulation resistance should be measured regularly to ensure safety
Factors like temperature and humidity can affect insulation resistance
Some of the top questions asked at the ArcelorMittal Nippon Steel Electrical Shift Engineer interview -
based on 3 interviews
Interview experience
based on 2 reviews
Rating in categories
Deputy Manager
716
salaries
| ₹4.5 L/yr - ₹15.5 L/yr |
Assistant Manager
563
salaries
| ₹3 L/yr - ₹11.6 L/yr |
Manager
515
salaries
| ₹6 L/yr - ₹21 L/yr |
Assistant Field Engineer
382
salaries
| ₹1.8 L/yr - ₹5.2 L/yr |
Engineer
344
salaries
| ₹2.4 L/yr - ₹7.5 L/yr |
Tata Steel
JSW Steel
Steel Authority Of India
Vedanta Limited