Conductor size is determined by the amount of current it needs to carry and the distance it needs to travel.
Conductor size is measured in American Wire Gauge (AWG) or circular mils (CM)
Larger conductors can carry more current without overheating
Distance also affects conductor size as longer distances require larger conductors to prevent voltage drop
Conductor size is also determined by the type of insulation and the env...
Current transformers and potential transformers are used for measuring electrical parameters.
Current transformers are used to measure high currents in power systems and step down the current to a level that can be measured by instruments.
Potential transformers are used to measure high voltages in power systems and step down the voltage to a level that can be measured by instruments.
Both transformers are used to provide...
Top trending discussions
I was interviewed in Sep 2024.
I was interviewed in Sep 2024.
I applied via Company Website and was interviewed in Aug 2024. There was 1 interview round.
posted on 10 Dec 2024
I applied via Walk-in and was interviewed in Jun 2024. There were 3 interview rounds.
I was responsible for overseeing the operation and maintenance of equipment to ensure smooth functioning of the plant.
Managed daily operations of equipment
Performed routine maintenance tasks
Troubleshooted equipment issues
Ensured compliance with safety regulations
Collaborated with other team members for efficient plant operation
posted on 19 Dec 2024
posted on 26 Nov 2024
I applied via Approached by Company and was interviewed before Nov 2023. There was 1 interview round.
posted on 31 Jan 2024
I applied via Approached by Company and was interviewed before Jan 2023. There was 1 interview round.
The type of excitation system in a generator determines how the generator is powered and controlled.
There are mainly two types of excitation systems: static excitation system and brushless excitation system.
Static excitation systems use a separate DC power source to provide the field current to the generator.
Brushless excitation systems use the generator's own output to power the field winding.
Each type of excitation s...
Buchholz Relay is a protective device used in oil-filled transformers to detect faults such as internal arcing or overheating.
Monitors oil flow in transformer
Detects faults like internal arcing or overheating
Triggers alarm or trips circuit if fault detected
I applied via Walk-in and was interviewed before Feb 2023. There was 1 interview round.
based on 2 reviews
Rating in categories
Senior Engineer
14
salaries
| ₹2 L/yr - ₹5.2 L/yr |
Assistant Manager
13
salaries
| ₹3 L/yr - ₹10.5 L/yr |
Project Engineer
10
salaries
| ₹1.5 L/yr - ₹3.6 L/yr |
Electrical Engineer
10
salaries
| ₹2.2 L/yr - ₹3.9 L/yr |
Manager
5
salaries
| ₹6.7 L/yr - ₹10 L/yr |
Suzlon Group
ReNew
Tata Power
Adani Green Energy