A motor is a device that converts electrical energy into mechanical energy. There are various types of motors including AC motors, DC motors, and synchronous motors.
AC motors use alternating current to produce rotational motion, commonly found in household appliances.
DC motors use direct current and are often used in applications where speed control is important, such as in electric vehicles.
Synchronous motors operate ...
Top trending discussions
I applied via Walk-in and was interviewed before Feb 2021. There was 1 interview round.
The question covers topics related to electrical circuits and devices.
Star delta starter is used to reduce the starting current of induction motors.
Types of DC generators include shunt, series, and compound generators.
Tube light connection circuit involves connecting the starter, choke, and tube light in series.
Two-way switch connection is used to control a single light or group of lights from two different locations.
The answer includes information about types of starters, star delta connection, types of transformers, working of bukols relay, and types of DC motors.
Types of starters include direct-on-line starter, star delta starter, auto transformer starter, and resistance starter.
Star delta starter is used to reduce the starting current of induction motors.
Star delta starter circuit diagram consists of three contactors, a timer, ...
I appeared for an interview in Sep 2023.
Ohm's Law states that the voltage (V) in a circuit is equal to the current (I) multiplied by the resistance (R).
V = I * R
Voltage is measured in volts (V)
Current is measured in amperes (A)
Resistance is measured in ohms (Ω)
Example: If a circuit has a current of 2A flowing through a resistance of 5Ω, the voltage would be 10V (2A * 5Ω = 10V)
I appeared for an interview before Feb 2024.
I applied via Walk-in and was interviewed before Nov 2022. There were 2 interview rounds.
FMEA is Failure Modes and Effects Analysis used to identify and prioritize potential failures in a process or product.
FMEA involves identifying potential failure modes, their effects, and the likelihood of their occurrence.
To improve a control plan using FMEA, prioritize high-risk failure modes and implement controls to prevent or mitigate them.
Regularly review and update the FMEA and control plan based on new informat...
Failure Mode and Effects Analysis
FMEA stands for Failure Mode and Effects Analysis
It is a systematic method for identifying and preventing potential failures in a design or process
Helps in prioritizing and addressing potential failure modes based on their impact and likelihood
Commonly used in industries such as automotive, aerospace, and manufacturing
Example: Conducting FMEA on a car engine to identify potential failur
5S is a methodology used to organize a workplace for efficiency and effectiveness by sorting, setting in order, shining, standardizing, and sustaining.
Sort - Remove unnecessary items from the workplace.
Set in order - Organize remaining items in a logical manner.
Shine - Clean and inspect the workplace regularly.
Standardize - Establish standards and procedures for maintaining the workplace.
Sustain - Ensure the 5S system ...
To find the error in root cause, analyze the situation, gather data, identify potential causes, and test hypotheses.
Analyze the situation thoroughly to understand the context of the error.
Gather data from various sources to identify patterns or anomalies.
Identify potential causes by brainstorming and using tools like fishbone diagrams or 5 Whys.
Test hypotheses by conducting experiments or simulations to validate the ro...
I applied via Referral and was interviewed before Feb 2023. There was 1 interview round.
I applied via Campus Placement and was interviewed in Nov 2021. There were 2 interview rounds.
There is a technical round for freshers in 50 marks question paper .
posted on 15 Jan 2025
I applied via AmbitionBox and was interviewed in Dec 2024. There were 5 interview rounds.
An overload relay works by monitoring the current flowing through a motor and tripping when the current exceeds a set limit.
Monitors the current flowing through a motor
Trips and interrupts power when current exceeds a set limit
Protects the motor from damage due to overloading
Can be reset manually after tripping
Insulation resistance is measured using a megohmmeter to apply a high voltage and measure the resistance of the insulation material.
Use a megohmmeter to apply a high voltage to the insulation material
Measure the resistance of the insulation material to determine its insulation resistance
Insulation resistance is typically measured in megaohms (MΩ)
Regular insulation resistance testing helps prevent electrical failures an
Electrical safety can be ensured by following proper procedures, using appropriate equipment, and staying vigilant.
Always use insulated tools when working on live circuits
Ensure circuits are de-energized before working on them
Wear appropriate personal protective equipment (PPE) such as gloves and goggles
Regularly inspect and maintain electrical equipment to prevent malfunctions
Follow safety guidelines and procedures ou
Preventive maintenance on a motor involves inspecting, cleaning, lubricating, and testing the motor to ensure optimal performance and prevent breakdowns.
Inspect the motor for any signs of wear or damage
Clean the motor and its components to remove dirt and debris
Lubricate moving parts to reduce friction and wear
Test the motor's performance using appropriate tools and equipment
Replace any worn out parts or components as
To succeed in an interview, it is important to prepare thoroughly, practice common interview questions, research the company, dress professionally, and demonstrate enthusiasm and confidence.
Thoroughly research the company and the position you are applying for
Practice common interview questions and prepare examples of your skills and experiences
Dress professionally and appropriately for the interview
Demonstrate enthusia...
A star-delta starter is used to reduce the starting current of a motor by initially connecting the motor windings in a star configuration and then switching to a delta configuration.
The motor windings are initially connected in a star configuration during starting to reduce the starting current.
After a certain period, the windings are switched to a delta configuration to achieve full speed and torque.
This transition fr...
Undervoltage faults occur when the voltage in a system drops below the normal operating level, leading to potential equipment damage or malfunction.
Undervoltage faults can be caused by issues such as power supply fluctuations, equipment failures, or overloaded circuits.
These faults can lead to equipment damage, reduced efficiency, or complete shutdown of systems.
Examples include a power surge causing a drop in voltage,...
Overvoltage faults are electrical faults that occur when the voltage in a circuit exceeds the normal operating range.
Overvoltage faults can damage electrical components and equipment.
They can be caused by lightning strikes, power surges, or faulty equipment.
Protective devices like surge protectors and voltage regulators can help prevent overvoltage faults.
Examples include a power surge from a lightning strike damaging ...
A thermal relay is used to protect electrical circuits from overloads by monitoring the temperature of the circuit and tripping when it exceeds a certain threshold.
Monitors the temperature of the electrical circuit
Trips and disconnects the circuit when temperature exceeds a set limit
Protects against overloads and overheating
Commonly used in motor protection applications
An RDOL starter is a type of reduced voltage starter used in electrical systems to reduce the starting current and torque of a motor.
RDOL stands for Reduced Direct Online starter.
It is used to start induction motors in a controlled manner.
RDOL starters reduce the voltage supplied to the motor during starting to limit the inrush current.
This helps in reducing mechanical stress on the motor and connected equipment.
Common...
Various methods exist to measure motor RPM, including tachometers, frequency counters, and optical sensors.
Tachometer: A device that directly measures the rotational speed of the motor shaft.
Frequency Counter: Measures the frequency of the motor's output signal, which can be converted to RPM.
Optical Sensor: Uses light beams to detect the rotation of a marked disk attached to the motor.
Stroboscope: A flashing light that...
Safety devices in conveyor systems prevent accidents and ensure smooth operation, protecting both workers and equipment.
Emergency Stop Buttons: Allow immediate shutdown of the conveyor in case of an emergency.
Safety Guards: Physical barriers that prevent access to moving parts, reducing the risk of injury.
Photoelectric Sensors: Detect objects or personnel in the conveyor's path, stopping operation if necessary.
Overload...
The negative charge of an ESP system electrode helps in attracting and collecting particulate matter from flue gases.
Electrostatic Precipitators (ESPs) use negatively charged electrodes to ionize particles in the gas stream.
The negative charge creates an electric field that attracts positively charged particles, aiding in their collection.
For example, in power plants, ESPs remove ash and other pollutants from exhaust g...
Healthy silica gel is typically blue or orange, while unhealthy silica gel turns pink or green, indicating moisture absorption.
Healthy silica gel is often blue or orange, indicating it is dry.
Unhealthy silica gel turns pink or green when it absorbs moisture.
Blue silica gel contains cobalt chloride, which changes color when wet.
Orange silica gel is a safer alternative that changes from orange to green when saturated.
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Assistant Manager
40
salaries
| ₹3.5 L/yr - ₹10.6 L/yr |
Engineer
29
salaries
| ₹2 L/yr - ₹5 L/yr |
Senior Engineer
25
salaries
| ₹3.6 L/yr - ₹7 L/yr |
Electrical Engineer
18
salaries
| ₹2.7 L/yr - ₹5 L/yr |
Deputy Manager
16
salaries
| ₹6.5 L/yr - ₹10 L/yr |
SHYAM METALICS AND ENERGY
Rashmi Metaliks
Jai Balaji Group