On electrical subject
I applied via Job Portal and was interviewed before Mar 2021. There were 3 interview rounds.
I applied via Naukri.com and was interviewed in Jul 2024. There was 1 interview round.
Motor protection settings are parameters set to protect the motor from damage due to overcurrent, overload, overheating, etc.
Motor protection settings include overload relay, thermal overload relay, circuit breaker, fuses, etc.
These settings are crucial for preventing motor damage and ensuring safe operation.
Examples of motor protection settings include setting the overload relay to trip at a certain current level, set...
I appeared for an interview before Mar 2024, where I was asked the following questions.
HIRA stands for Hazard Identification and Risk Assessment, crucial for workplace safety management.
HIRA is a systematic process to identify hazards in the workplace.
It involves assessing risks associated with identified hazards.
Example: Conducting HIRA for a construction site to identify fall risks.
HIRA helps in implementing control measures to mitigate risks.
Regular HIRA updates are essential as workplace conditions c
Risk analysis is crucial for identifying, assessing, and mitigating potential hazards in the workplace.
Identifies potential hazards: For example, analyzing machinery to prevent accidents.
Assesses risk levels: Evaluating the likelihood and impact of identified hazards.
Informs decision-making: Helps prioritize safety measures based on risk severity.
Enhances compliance: Ensures adherence to safety regulations and standard...
MTTR stands for Mean Time To Repair and MTBF stands for Mean Time Between Failures.
MTTR is the average time taken to repair a failed component or system.
MTBF is the average time between failures of a component or system.
MTTR is calculated as total downtime divided by the number of failures.
MTBF is calculated as total uptime divided by the number of failures.
MTTR is usually measured in hours or minutes, while MTBF is me...
Balancing an impeller involves adjusting the weight distribution to minimize vibration and improve performance.
Identify the heavy spots on the impeller
Add or remove material to balance the impeller
Use a balancing machine to check the balance
Repeat the process until the impeller is properly balanced
posted on 30 Sep 2024
I applied via Referral and was interviewed in Mar 2021. There were 3 interview rounds.
There are various types of transformers, including power transformers, distribution transformers, autotransformers, and instrument transformers.
Power transformers are used to transfer electrical energy between different voltage levels.
Distribution transformers are used to step down the voltage for distribution to consumers.
Autotransformers have a single winding and are used for voltage regulation.
Instrument transformer...
The VCB in our plant has a rating of 2000A.
The VCB stands for Vacuum Circuit Breaker.
It is used to interrupt or make electrical circuits in a vacuum environment.
The rating of 2000A indicates its maximum current-carrying capacity.
This rating ensures that the VCB can handle high electrical loads without tripping or malfunctioning.
based on 1 interview
Interview experience
Assistant Manager
40
salaries
| ₹3.5 L/yr - ₹10.6 L/yr |
Engineer
29
salaries
| ₹2 L/yr - ₹5 L/yr |
Senior Engineer
25
salaries
| ₹3.6 L/yr - ₹7 L/yr |
Electrical Engineer
18
salaries
| ₹2.7 L/yr - ₹5 L/yr |
Deputy Manager
16
salaries
| ₹6.5 L/yr - ₹10 L/yr |
SHYAM METALICS AND ENERGY
Rashmi Metaliks
Jai Balaji Group
Electrotherm