i
Alembic Pharmaceuticals
Filter interviews by
I applied via Approached by Company and was interviewed before Mar 2022. There were 4 interview rounds.
Fundamental of Analytical techniques, Chemistry of wet analysis, Characterisation techniques, Quantitative and qualitative analysis, Fundamentals of Chromatography, Spectroscopy, Spectrometry l, QC, QA, RA, GLP, cGMP.
Top trending discussions
posted on 17 Dec 2023
The percentage of buffer used in mobile phase and the use of SLS in disso and its allowed percentage.
The percentage of buffer used in the mobile phase depends on the specific experiment and the desired separation of compounds.
Buffer is used in the mobile phase to maintain the pH and ionic strength, which can affect the separation and stability of analytes.
The percentage of buffer can range from 5% to 50% or more, depen...
The sink condition is decided based on various factors such as the purpose of the sink, the type of research being conducted, and the desired outcome.
Consider the purpose of the sink - Is it for disposal, storage, or analysis of substances?
Evaluate the type of research being conducted - Does it involve chemical reactions, biological samples, or physical measurements?
Assess the desired outcome - Are you looking for pres...
The criteria/limit for impurity recovery depends on the specific research study and the desired purity level.
The criteria for impurity recovery may include the maximum allowable impurity concentration or percentage.
The limit for impurity recovery can be determined based on regulatory guidelines or industry standards.
The desired purity level may vary depending on the application or intended use of the research findings.
...
Mass balance is a principle used in various scientific disciplines to account for the mass of substances in a system.
Mass balance is based on the principle of conservation of mass, which states that mass cannot be created or destroyed, only transferred or transformed.
It involves tracking the inputs, outputs, and accumulation of mass within a system.
Mass balance equations are commonly used in environmental science, chem...
RF values are important in chromatography to identify and separate compounds.
RF value is the ratio of the distance traveled by a compound to the distance traveled by the solvent front in chromatography.
It helps in identifying and separating compounds based on their polarity and solubility.
RF values can be used to compare compounds and determine their purity.
For example, in thin-layer chromatography, RF values are used ...
posted on 20 Apr 2024
I applied via Referral and was interviewed before Jul 2022. There were 3 interview rounds.
A 50 ppm solution contains 50 parts of solute per million parts of solution.
ppm stands for parts per million.
It is a measure of concentration.
In a 50 ppm solution, there are 50 parts of solute per million parts of solution.
For example, if we have a 1 million mL solution, there would be 50 mL of solute in it.
posted on 22 Oct 2021
I applied via Campus Placement and was interviewed before Oct 2020. There were 3 interview rounds.
I applied via Walk-in and was interviewed before Jan 2020. There was 1 interview round.
Mass spectrometry is a technique used to identify and quantify molecules based on their mass-to-charge ratio.
Electrospray ionization (ESI)
Matrix-assisted laser desorption/ionization (MALDI)
Gas chromatography-mass spectrometry (GC-MS)
Liquid chromatography-mass spectrometry (LC-MS)
Time-of-flight mass spectrometry (TOF-MS)
UV spectrometry is a technique that measures the absorption or transmission of ultraviolet light by a sample.
UV spectrometry is based on the principle that different molecules absorb UV light at specific wavelengths.
It is commonly used in analytical chemistry to determine the concentration of a substance in a sample.
UV spectrometry can be used to analyze the purity of a compound or identify unknown substances.
The instr...
To prepare 0.1 N HCl and NaOH, you need to calculate the required amount of the respective chemicals and dilute them in water.
Calculate the molar mass of HCl and NaOH
Determine the volume of solution needed
Use the formula: Normality (N) = (Number of equivalents / Volume of solution in liters)
For 0.1 N HCl, calculate the number of equivalents of HCl and dilute it to the desired volume
For NaOH, calculate the number of equ...
Quality assurance is the process of ensuring that products or services meet the desired level of quality.
It involves establishing standards and procedures to ensure that products or services meet those standards.
It includes monitoring and evaluating the quality of products or services to identify areas for improvement.
It also involves taking corrective action when necessary to address quality issues.
Examples include co...
Recall definitions
Recall: the ability to retrieve information from memory
Definition: a statement that explains the meaning of a word or phrase
Research: the systematic investigation into and study of materials and sources in order to establish facts and reach new conclusions
Associate: a person who works with others towards a common goal
Hypothesis: a proposed explanation for a phenomenon
Experiment: a scientific procedure...
The type of HPLC used depends on the specific research requirements and objectives.
There are several types of HPLC systems available, including reverse phase, normal phase, ion exchange, size exclusion, and affinity chromatography.
The choice of HPLC system depends on the properties of the analyte, such as polarity, size, charge, and affinity.
For example, reverse phase HPLC is commonly used for the separation of nonpola...
UV detectors and HPLC detectors are used in research to analyze and quantify substances.
UV detectors are commonly used in UV-visible spectroscopy to measure the absorption of light by a sample at different wavelengths.
HPLC detectors are used in high-performance liquid chromatography to detect and quantify the components of a mixture.
Common types of UV detectors include diode array detectors (DAD) and photodiode array d...
Matrix in MALDI MS system is a substance used to assist in ionization of the sample for analysis.
Matrix is a substance that absorbs energy from the laser and transfers it to the sample, causing ionization.
The choice of matrix depends on the type of sample being analyzed.
Common matrices include alpha-cyano-4-hydroxycinnamic acid (CHCA) and sinapinic acid (SA).
I applied via Naukri.com and was interviewed in Sep 2018. There were 5 interview rounds.
Seeking new challenges and opportunities for growth.
Desire for new challenges and opportunities for growth
Seeking a more stimulating work environment
Looking to expand skill set and knowledge
Company restructuring or downsizing
Relocation to a new area
posted on 18 Dec 2021
I applied via Naukri.com and was interviewed in Nov 2021. There was 1 interview round.
Column and mobile phase selection is based on the analyte properties and separation goals.
Consider the analyte's physicochemical properties such as polarity, molecular weight, and stability.
Choose a column with appropriate stationary phase chemistry (e.g., C18 for hydrophobic compounds).
Optimize mobile phase composition (solvent ratio, pH, buffer) for desired separation.
Consider the separation goals (resolution, select...
Some of the top questions asked at the Alembic Pharmaceuticals Research Scientist interview for freshers -
based on 1 interview
Interview experience
based on 66 reviews
Rating in categories
Executive
1.9k
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Executive
1.3k
salaries
| ₹0 L/yr - ₹0 L/yr |
Junior Executive
762
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
697
salaries
| ₹0 L/yr - ₹0 L/yr |
Executive Production
428
salaries
| ₹0 L/yr - ₹0 L/yr |
Sun Pharmaceutical Industries
Cipla
DRJ & CO
Lupin