Different types of compressors used in HVAC systems include reciprocating, rotary, scroll, and centrifugal compressors.
Reciprocating compressors use pistons to compress refrigerant gas.
Rotary compressors use rotating vanes or blades to compress the refrigerant.
Scroll compressors have two spiral-shaped scrolls to compress the refrigerant.
Centrifugal compressors use a rotating impeller to create centrifugal force and com...
Various types of gases used in HVAC systems include refrigerants, nitrogen, oxygen, and carbon dioxide.
Refrigerants are commonly used in HVAC systems to absorb and release heat.
Nitrogen is used for pressure testing and purging air from the system.
Oxygen is used in combustion processes for heating systems.
Carbon dioxide can be used in certain types of HVAC systems for ventilation purposes.
Top trending discussions
posted on 17 Nov 2024
Electrical engineers are responsible for designing, developing, testing, and supervising the manufacturing of electrical equipment.
Designing electrical systems and equipment
Developing new technologies and products
Testing equipment for safety and efficiency
Supervising the manufacturing process
Troubleshooting and repairing electrical equipment
posted on 10 Oct 2024
I applied via Referral and was interviewed in Sep 2024. There was 1 interview round.
Transformer vector group is a method used to represent the phase shift between the primary and secondary windings of a transformer.
Transformer vector group indicates the relationship between the primary and secondary winding phases.
It helps in determining the connection and phase shift of the transformer windings.
Common vector groups include Yy0, Yd1, Dyn11, etc.
Vector group is important for parallel operation of trans
VBD test is conducted in transformers to ensure insulation integrity and detect any potential faults.
VBD test helps in identifying any weak spots in the insulation of the transformer
It helps in preventing breakdowns and ensuring the safety and reliability of the transformer
By conducting VBD test, any potential faults can be detected early and necessary maintenance can be carried out
It is a standard procedure in transfo
posted on 28 Dec 2024
I applied via LinkedIn and was interviewed before Oct 2023. There was 1 interview round.
HVAC stands for Heating, Ventilation, and Air Conditioning.
HVAC stands for Heating, Ventilation, and Air Conditioning
HVAC is responsible for maintaining indoor air quality and comfort
HVAC systems include components like furnaces, air conditioners, and ventilation ducts
The fan coil unit (FCU) is full of water or condensate.
Check for clogged drain lines or condensate pump failure.
Inspect the drain pan for any leaks or cracks.
Ensure the unit is properly leveled to allow for proper drainage.
Check the air filter for any blockages that may be causing the unit to overflow.
I applied via Walk-in and was interviewed in Jul 2023. There were 3 interview rounds.
I was interviewed in Aug 2023.
posted on 21 May 2023
I applied via Company Website and was interviewed in Apr 2023. There were 2 interview rounds.
posted on 16 Apr 2023
I applied via Naukri.com and was interviewed in Mar 2023. There were 2 interview rounds.
based on 1 interview
Interview experience
based on 2 reviews
Rating in categories
Senior Software Engineer
4
salaries
| ₹1.2 L/yr - ₹21 L/yr |
Electrical Technician
4
salaries
| ₹1.5 L/yr - ₹7.2 L/yr |
Project Administrator
4
salaries
| ₹6.5 L/yr - ₹10 L/yr |
Hvac Technician
4
salaries
| ₹5 L/yr - ₹10 L/yr |
Firefighter
4
salaries
| ₹0.7 L/yr - ₹1 L/yr |
TCS
Infosys
Wipro
HCLTech