Transformer safety measures include proper grounding, regular maintenance, and protective devices.
Proper grounding to prevent electrical shock
Regular maintenance to prevent overheating and other issues
Protective devices such as fuses and circuit breakers to prevent overloading
Use of personal protective equipment (PPE) when working with transformers
Proper storage and handling of transformers to prevent damage
To calculate KWH to Amps, divide KWH by hours and then divide by voltage.
Divide KWH by hours to get KW
Divide KW by voltage to get Amps
Formula: Amps = KWH / (hours * voltage)
Example: 100 KWH used in 10 hours with 120V = 0.83 Amps
Top trending discussions
I applied via Naukri.com and was interviewed before May 2018. There were 5 interview rounds.
I applied via Recruitment Consultant and was interviewed in Jun 2021. There was 1 interview round.
I have 10 years of work experience in mechanical engineering.
Designed and implemented mechanical systems for various projects
Performed analysis and simulations to optimize performance
Collaborated with cross-functional teams to ensure project success
Managed and supervised junior engineers
Implemented cost-saving measures in manufacturing processes
I applied via Approached by Company and was interviewed in Mar 2023. There were 3 interview rounds.
I was interviewed in Aug 2024.
I applied via Naukri.com and was interviewed in Nov 2021. There was 1 interview round.
I was interviewed in May 2022.
I applied via Approached by Company and was interviewed in Apr 2022. There were 2 interview rounds.
Bukolze relays are used in electrical engineering for their high reliability and ability to handle high voltage and current.
Bukolze relays are known for their robustness and durability.
They are commonly used in power systems and industrial applications.
These relays can handle high voltage and current levels, making them suitable for heavy-duty operations.
They provide reliable switching and protection in electrical circ...
CT and PT are used in electrical engineering for measurement and protection purposes.
CT (Current Transformer) is used to measure high currents and step them down to a level suitable for measurement instruments.
PT (Potential Transformer) is used to measure high voltages and step them down to a level suitable for measurement instruments.
CTs and PTs are also used for protection purposes, such as detecting faults and isola...
The number of transformer production varies depending on the company and market demand.
The number of transformer production is influenced by factors such as market demand, company size, and production capacity.
Large transformer manufacturers may produce thousands of transformers per year.
Smaller companies or custom transformer manufacturers may have lower production volumes.
The production volume can also vary based on ...
There are several types of breakers used in electrical engineering.
Circuit breakers are used to protect electrical circuits from overloads and short circuits.
Some common types of breakers include thermal, magnetic, and hydraulic-magnetic breakers.
Thermal breakers use a bimetallic strip to detect excessive heat and trip the circuit.
Magnetic breakers use a solenoid to detect high currents and trip the circuit.
Hydraulic-m...
based on 1 interview
Interview experience
based on 22 reviews
Rating in categories
Facility Executive
230
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
118
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Facility Manager
107
salaries
| ₹0 L/yr - ₹0 L/yr |
Technical Executive
80
salaries
| ₹0 L/yr - ₹0 L/yr |
Facility Manager
79
salaries
| ₹0 L/yr - ₹0 L/yr |
Sodexo
Compass Group Support Services
CBRE
JLL