Filter interviews by
I was interviewed in Sep 2023.
About background and family
Samples are prepared by following standard operating procedures and using proper equipment to ensure accuracy and consistency.
Follow standard operating procedures (SOPs) for sample preparation
Use proper equipment and tools for accurate measurements
Ensure cleanliness and proper labeling of samples
Document all steps taken during sample preparation
Verify the accuracy of prepared samples through quality control checks
Samples can be created by following a specific procedure to ensure accuracy and consistency.
Collect the necessary materials and equipment for sampling
Follow a standardized sampling procedure to ensure consistency
Label each sample with relevant information such as date, time, and location
Store samples in appropriate containers to prevent contamination
Document the sampling process for traceability and quality control pur
Sampling of raw materials or finished products is done following specific procedures to ensure accuracy and representativeness.
Follow SOPs for sampling raw materials or finished products
Use appropriate sampling tools such as scoops, pipettes, or sampling thieves
Ensure proper labeling and documentation of samples
Store samples in suitable containers to prevent contamination
Transport samples to the laboratory for analysis
Top trending discussions
I applied via Naukri.com and was interviewed in Feb 2024. There were 6 interview rounds.
Graduated phamrmacy aptitude test
Antibacterial activity cheak of thriphala diffusion method
Emergency case study
Production tablet in coding
Work simple with group discussion
I applied via Walk-in and was interviewed in Dec 2021. There was 1 interview round.
Potassium iodide (KI) is commonly used in Karl Fischer (KF) titration.
Potassium iodide (KI) is added to the Karl Fischer reagent to enhance the solubility of water.
KI reacts with water to form iodine, which is then titrated with the Karl Fischer reagent.
The reaction between KI and water in KF titration is as follows: KI + SO2 + H2O → KHSO4 + I2
The iodine formed is then quantitatively determined by titration with the Ka...
HPLC is a technique used to separate, identify, and quantify components in a mixture.
HPLC stands for High Performance Liquid Chromatography.
It is commonly used in pharmaceuticals, food and beverage, and environmental testing.
HPLC can separate and quantify complex mixtures of compounds.
It can be used to detect impurities in drugs and determine their concentration.
HPLC can also be used to analyze the composition of food ...
FTIR is a powerful analytical technique used for identifying and quantifying chemical compounds.
Advantages: non-destructive, rapid, requires minimal sample preparation, can analyze a wide range of compounds, can be used for qualitative and quantitative analysis
Disadvantages: expensive equipment, requires trained personnel, may require calibration, may not be suitable for analyzing certain compounds
Example: FTIR can be ...
Always talk with medium tone..
I applied via Naukri.com and was interviewed in Feb 2024. There were 6 interview rounds.
Graduated phamrmacy aptitude test
Antibacterial activity cheak of thriphala diffusion method
Emergency case study
Production tablet in coding
Work simple with group discussion
I applied via Walk-in and was interviewed in Dec 2021. There was 1 interview round.
Potassium iodide (KI) is commonly used in Karl Fischer (KF) titration.
Potassium iodide (KI) is added to the Karl Fischer reagent to enhance the solubility of water.
KI reacts with water to form iodine, which is then titrated with the Karl Fischer reagent.
The reaction between KI and water in KF titration is as follows: KI + SO2 + H2O → KHSO4 + I2
The iodine formed is then quantitatively determined by titration with the Ka...
HPLC is a technique used to separate, identify, and quantify components in a mixture.
HPLC stands for High Performance Liquid Chromatography.
It is commonly used in pharmaceuticals, food and beverage, and environmental testing.
HPLC can separate and quantify complex mixtures of compounds.
It can be used to detect impurities in drugs and determine their concentration.
HPLC can also be used to analyze the composition of food ...
FTIR is a powerful analytical technique used for identifying and quantifying chemical compounds.
Advantages: non-destructive, rapid, requires minimal sample preparation, can analyze a wide range of compounds, can be used for qualitative and quantitative analysis
Disadvantages: expensive equipment, requires trained personnel, may require calibration, may not be suitable for analyzing certain compounds
Example: FTIR can be ...
Always talk with medium tone..
To prepare chlorobenzene, benzene is treated with chlorine in the presence of a catalyst. Phenol is acidic and polar. Bulk density is the mass of a unit volume of a substance.
Chlorobenzene is prepared by treating benzene with chlorine in the presence of a catalyst
Known solvents for chlorobenzene include ethanol, diethyl ether, and carbon tetrachloride
Phenol is acidic due to the presence of a hydroxyl group, and it is p...
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Chemist
7
salaries
| ₹2.5 L/yr - ₹3 L/yr |
Assistant Manager
6
salaries
| ₹4.1 L/yr - ₹5.2 L/yr |
QC Chemist
6
salaries
| ₹1.1 L/yr - ₹3.2 L/yr |
Accounts Manager
5
salaries
| ₹9 L/yr - ₹9 L/yr |
Production Chemist
4
salaries
| ₹1.1 L/yr - ₹3 L/yr |
Sun Pharmaceutical Industries
Cipla
Dr. Reddy's
Biocon Limited