Evaporation system is a process of converting liquid into vapor by heating or reducing pressure.
Evaporation system is used in various industries like food, chemical, and pharmaceuticals.
It is used for concentration of solutions, separation of volatile components, and purification of liquids.
Examples of evaporation systems include rotary evaporators, falling film evaporators, and flash evaporators.
Heat transfer is the movement of thermal energy from one object to another, while mass transfer is the movement of mass from one place to another.
Heat transfer involves the transfer of thermal energy due to a temperature difference, while mass transfer involves the transfer of mass due to a concentration difference.
Heat transfer can occur through conduction, convection, or radiation, while mass transfer can occur throu...
Aditya Birla Group interview questions for popular designations
I applied via Company Website and was interviewed in Aug 2022. There were 3 interview rounds.
Get interview-ready with Top Aditya Birla Group Interview Questions
I applied via Referral and was interviewed before Oct 2022. There were 3 interview rounds.
Normal aptitudes queation and English questions
HRM stands for Human Resource Management, which involves managing employees within an organization. Different laws related to HR include labor laws, anti-discrimination laws, and employment laws.
HRM involves recruiting, training, and managing employees within an organization
Labor laws regulate issues such as minimum wage, working hours, and overtime pay
Anti-discrimination laws prohibit discrimination based on factors l...
I applied via Company Website and was interviewed in Mar 2022. There were 3 interview rounds.
HT breaker vacuum bottle integrity test is performed to ensure the vacuum bottle is free from leaks and can withstand high voltage.
The test is performed using a vacuum pump and a pressure gauge.
The vacuum pump is connected to the breaker's vacuum bottle and the pressure gauge is connected to the pump.
The vacuum pump is turned on and the pressure gauge is monitored for any drop in pressure.
If the pressure drops, it indi...
The trip supervision relay is responsible for monitoring the trip circuit of a protective device and ensuring its proper functioning.
It supervises the trip circuit to detect any faults or abnormalities.
It ensures that the trip circuit is properly energized and ready to operate when needed.
It monitors the continuity and integrity of the trip circuit wiring.
It can provide alarms or indications in case of trip circuit fai...
ELCB and RCCB are both electrical safety devices, but differ in their operating principles.
ELCB detects earth leakage current and operates on the principle of electromagnetic induction.
RCCB detects both earth leakage and residual current and operates on the principle of differential current transformer.
ELCB is less sensitive and slower in operation compared to RCCB.
RCCB is more expensive than ELCB but provides better p...
Tan delta test is a diagnostic test to measure the quality of insulation in electrical equipment.
It measures the dissipation factor of insulation material
It helps to detect any defects or deterioration in the insulation
It is commonly used for testing transformers, cables, and capacitors
The test involves applying a voltage to the equipment and measuring the current and phase angle
A high tan delta value indicates poor in
There are several types of motor testing including insulation resistance, winding resistance, and vibration analysis.
Insulation resistance testing measures the resistance of the insulation material surrounding the motor windings.
Winding resistance testing measures the resistance of the motor windings themselves.
Vibration analysis testing measures the level of vibration in the motor to detect any potential issues.
Other ...
PI test is a method to measure the insulation resistance of the motor winding.
PI stands for Polarization Index.
It is a ratio of insulation resistance measured at 10 minutes to that measured at 1 minute.
It is used to determine the condition of the motor winding insulation.
A PI value of 2 or more indicates good insulation.
A low PI value indicates poor insulation and the motor may need to be rewound or replaced.
I applied via Company Website and was interviewed in Nov 2022. There were 2 interview rounds.
I applied via LinkedIn and was interviewed in Mar 2022. There were 3 interview rounds.
Top trending discussions
The duration of Aditya Birla Group interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 185 interviews
Interview experience
based on 2k reviews
Rating in categories
Assistant Manager
358
salaries
| ₹5 L/yr - ₹19 L/yr |
Manager
232
salaries
| ₹9 L/yr - ₹35 L/yr |
Senior Manager
166
salaries
| ₹9.2 L/yr - ₹37 L/yr |
Deputy Manager
134
salaries
| ₹6 L/yr - ₹25.1 L/yr |
Sales Manager
115
salaries
| ₹2 L/yr - ₹9.4 L/yr |
Tata Group
Reliance Industries
Mahindra & Mahindra
Hindustan Unilever