Filter interviews by
Safety equipments are necessary to prevent accidents and injuries in the workplace.
Safety equipments provide protection against potential hazards and risks.
They can minimize the severity of injuries in case of accidents.
They can also prevent accidents from happening in the first place.
Examples of safety equipments include helmets, safety glasses, gloves, and safety harnesses.
Using safety equipments is a legal requireme...
Pressure drop from boiler drum to superheater is due to the decrease in steam density and frictional losses.
Pressure drop occurs due to the decrease in steam density as it passes from the boiler drum to the superheater.
Frictional losses also contribute to the pressure drop.
The pressure drop is necessary to ensure proper steam flow and temperature control in the superheater.
Factors such as pipe length, diameter, and ben...
To monitor and control the oxygen levels in the flue gas between the economizer and air preheater.
Installing an O2 analyzer between the economizer and air preheater helps optimize combustion efficiency.
It allows for real-time monitoring of oxygen levels in the flue gas, enabling adjustments to the air-to-fuel ratio.
Maintaining the optimal oxygen levels ensures complete combustion and reduces fuel consumption.
By control...
Maintaining above 120 degree ESP temperature is important for efficient operation and prevention of corrosion.
Higher ESP temperature ensures efficient removal of particulate matter from flue gas.
It helps in preventing corrosion of the ESP components.
Maintaining temperature above 120 degrees ensures optimal performance of the ESP system.
Lower temperatures can lead to reduced efficiency and increased maintenance requirem...
The critical speed of a turbine is the rotational speed at which the turbine experiences resonance and can lead to catastrophic failure.
Critical speed is the speed at which the natural frequency of the turbine matches the excitation frequency.
It is important to operate the turbine below its critical speed to avoid resonance.
Resonance can cause excessive vibrations, leading to fatigue and failure of turbine components.
T...
Top trending discussions
I applied via Naukri.com and was interviewed in Feb 2020. There were 3 interview rounds.
I applied via Recruitment Consultant and was interviewed in Jan 2020. There were 3 interview rounds.
I applied via Newspaper Ad and was interviewed before Nov 2021. There were 2 interview rounds.
I applied via Approached by Company and was interviewed before Sep 2021. There were 2 interview rounds.
posted on 21 Dec 2024
I applied via LinkedIn and was interviewed before Dec 2023. There was 1 interview round.
Power distribution is the process of delivering electricity from power plants to consumers through a network of transmission and distribution lines.
Electricity is generated at power plants using various sources such as coal, natural gas, nuclear, or renewable energy.
The electricity is then transmitted at high voltages over long distances through transmission lines to substations.
At substations, the voltage is reduced a...
Different types of sources of electricity include fossil fuels, nuclear power, renewable energy sources, and batteries.
Fossil fuels (coal, oil, natural gas)
Nuclear power
Renewable energy sources (solar, wind, hydro, geothermal)
Batteries (lithium-ion, lead-acid)
I am good work and good health a
I applied via Company Website
I have worked with synchronous alternators and have experience in transformer maintenance.
Worked with synchronous alternators in power generation applications
Performed maintenance on transformers to ensure proper functioning
Experience in troubleshooting and repairing electrical equipment
Knowledge of safety protocols and regulations in electrical engineering
Collaborated with team members to complete projects efficiently
I applied via Referral and was interviewed before Jan 2023. There was 1 interview round.
I applied via Job Portal and was interviewed in May 2023. There were 3 interview rounds.
Assistant Manager
360
salaries
| ₹4.9 L/yr - ₹18.7 L/yr |
Manager
253
salaries
| ₹8 L/yr - ₹34 L/yr |
Senior Manager
168
salaries
| ₹10 L/yr - ₹41.5 L/yr |
Deputy Manager
139
salaries
| ₹6.4 L/yr - ₹23 L/yr |
Sales Manager
118
salaries
| ₹2 L/yr - ₹9 L/yr |
UltraTech Cement
JK Cement
Grasim Industries
ACC