The eave height of a pre-engineered building with vertical connection of column and rafter can be found using trigonometry and the dimensions of the building components.
Calculate the vertical distance between the top of the column and the bottom of the rafter using trigonometry
Add this vertical distance to the height of the column to get the eave height
Ensure to consider any additional factors such as roof slope or ove
The missing dimensions in a cutting diagram can be calculated using basic geometry principles.
Identify the known dimensions in the cutting diagram
Use geometric formulas to calculate the missing dimensions
Consider angles and proportions in the diagram
Double check calculations to ensure accuracy
Calculation of weight for a tapered column involves determining the volume of each section and multiplying by the density of the material.
Calculate the volume of each section of the tapered column using appropriate geometric formulas.
Determine the weight of each section by multiplying the volume by the density of the material.
Sum up the weights of all sections to get the total weight of the tapered column.
I applied via Approached by Company and was interviewed in Dec 2022. There were 2 interview rounds.
Key skills for a Receptionist include excellent communication, organization, and customer service skills.
Strong communication skills, both verbal and written
Excellent organizational skills and attention to detail
Ability to multitask and prioritize tasks effectively
Friendly and professional demeanor with excellent customer service skills
Proficiency in using office equipment and software, such as phone systems and Micros...
I applied via Company Website and was interviewed in Feb 2020. There were 3 interview rounds.
Top trending discussions
posted on 15 Jan 2025
I applied via AmbitionBox and was interviewed in Dec 2024. There were 5 interview rounds.
An overload relay works by monitoring the current flowing through a motor and tripping when the current exceeds a set limit.
Monitors the current flowing through a motor
Trips and interrupts power when current exceeds a set limit
Protects the motor from damage due to overloading
Can be reset manually after tripping
Insulation resistance is measured using a megohmmeter to apply a high voltage and measure the resistance of the insulation material.
Use a megohmmeter to apply a high voltage to the insulation material
Measure the resistance of the insulation material to determine its insulation resistance
Insulation resistance is typically measured in megaohms (MΩ)
Regular insulation resistance testing helps prevent electrical failures an
Electrical safety can be ensured by following proper procedures, using appropriate equipment, and staying vigilant.
Always use insulated tools when working on live circuits
Ensure circuits are de-energized before working on them
Wear appropriate personal protective equipment (PPE) such as gloves and goggles
Regularly inspect and maintain electrical equipment to prevent malfunctions
Follow safety guidelines and procedures ou
Preventive maintenance on a motor involves inspecting, cleaning, lubricating, and testing the motor to ensure optimal performance and prevent breakdowns.
Inspect the motor for any signs of wear or damage
Clean the motor and its components to remove dirt and debris
Lubricate moving parts to reduce friction and wear
Test the motor's performance using appropriate tools and equipment
Replace any worn out parts or components as
To succeed in an interview, it is important to prepare thoroughly, practice common interview questions, research the company, dress professionally, and demonstrate enthusiasm and confidence.
Thoroughly research the company and the position you are applying for
Practice common interview questions and prepare examples of your skills and experiences
Dress professionally and appropriately for the interview
Demonstrate enthusia...
A star-delta starter is used to reduce the starting current of a motor by initially connecting the motor windings in a star configuration and then switching to a delta configuration.
The motor windings are initially connected in a star configuration during starting to reduce the starting current.
After a certain period, the windings are switched to a delta configuration to achieve full speed and torque.
This transition fr...
Undervoltage faults occur when the voltage in a system drops below the normal operating level, leading to potential equipment damage or malfunction.
Undervoltage faults can be caused by issues such as power supply fluctuations, equipment failures, or overloaded circuits.
These faults can lead to equipment damage, reduced efficiency, or complete shutdown of systems.
Examples include a power surge causing a drop in voltage,...
Overvoltage faults are electrical faults that occur when the voltage in a circuit exceeds the normal operating range.
Overvoltage faults can damage electrical components and equipment.
They can be caused by lightning strikes, power surges, or faulty equipment.
Protective devices like surge protectors and voltage regulators can help prevent overvoltage faults.
Examples include a power surge from a lightning strike damaging ...
A thermal relay is used to protect electrical circuits from overloads by monitoring the temperature of the circuit and tripping when it exceeds a certain threshold.
Monitors the temperature of the electrical circuit
Trips and disconnects the circuit when temperature exceeds a set limit
Protects against overloads and overheating
Commonly used in motor protection applications
An RDOL starter is a type of reduced voltage starter used in electrical systems to reduce the starting current and torque of a motor.
RDOL stands for Reduced Direct Online starter.
It is used to start induction motors in a controlled manner.
RDOL starters reduce the voltage supplied to the motor during starting to limit the inrush current.
This helps in reducing mechanical stress on the motor and connected equipment.
Common...
posted on 22 Jan 2025
posted on 16 Jan 2025
I was interviewed in Jan 2025.
Work experience in which field
posted on 13 Nov 2024
I applied via Walk-in and was interviewed in Oct 2024. There was 1 interview round.
To check the motor, you can perform various tests and inspections to ensure it is functioning properly.
Check for any physical damage or wear on the motor casing
Inspect the wiring connections for any loose or damaged wires
Measure the voltage and current going into the motor to ensure it is within the specified range
Test the motor's insulation resistance to check for any faults
Run the motor under load to see if it operat
Power analysis involves measuring and analyzing the electrical power consumption of a system or device.
Identify the components of the system or device that consume power.
Measure the current and voltage across these components using appropriate instruments.
Calculate the power consumption using the formula P = VI, where P is power, V is voltage, and I is current.
Analyze the power consumption data to identify any ineffici...
A transformer is a device that transfers electrical energy between two or more circuits through electromagnetic induction.
Transformers are used to increase or decrease voltage levels in electrical circuits.
They consist of two coils of wire, known as the primary and secondary coils.
Examples of transformers include power transformers used in electrical substations and voltage transformers in electronic devices.
based on 3 interviews
Interview experience
based on 42 reviews
Rating in categories
Production Engineer
5
salaries
| ₹5 L/yr - ₹11.6 L/yr |
CNC Machine Operator
5
salaries
| ₹4 L/yr - ₹6 L/yr |
Welding Foreman
5
salaries
| ₹4.6 L/yr - ₹5.5 L/yr |
Manager
4
salaries
| ₹18.5 L/yr - ₹20.4 L/yr |
Engineer
4
salaries
| ₹5 L/yr - ₹5.5 L/yr |
Tata Steel
Jindal Steel and Power
Bhushan Power & Steel
ArcelorMittal Nippon Steel