Viatris
Proud winner of ABECA 2024 - AmbitionBox Employee Choice Awards
Filter interviews by
Top trending discussions
posted on 29 May 2022
I applied via Company Website and was interviewed before May 2021. There was 1 interview round.
posted on 29 Jul 2022
I applied via Naukri.com and was interviewed before Jul 2021. There were 3 interview rounds.
I applied via Company Website and was interviewed in Jul 2024. There was 1 interview round.
Core values, Experience, Behavorial
posted on 12 Oct 2022
I applied via Approached by Company and was interviewed in Sep 2022. There were 2 interview rounds.
posted on 29 May 2022
I applied via Company Website and was interviewed before May 2021. There was 1 interview round.
ESI and APCI are ionization techniques used in mass spectrometry. Method development for impurities involves identification, quantification, and validation.
ESI (Electrospray Ionization) and APCI (Atmospheric Pressure Chemical Ionization) are ionization techniques used in mass spectrometry.
ESI is suitable for polar and ionic compounds, while APCI is suitable for nonpolar and less polar compounds.
ESI involves the formati...
I applied via Referral and was interviewed in Nov 2022. There were 3 interview rounds.
Current approaches on nitrosamine impurities
Analytical techniques such as LC-MS and GC-MS are commonly used to detect and quantify nitrosamine impurities in pharmaceuticals
Regulatory agencies have set limits on the acceptable levels of nitrosamine impurities in drugs
Manufacturers are required to conduct risk assessments and implement control measures to prevent nitrosamine contamination
Some common approaches to mitigat...
Quadrapoles are used in mass spectrometry to filter ions based on their mass-to-charge ratio.
Quadrapoles use radio frequency and direct current voltages to selectively filter ions.
They are composed of four parallel rods that create a quadrupole electric field.
Ions with a specific mass-to-charge ratio will oscillate within the field and pass through the filter.
Quadrapoles are commonly used in tandem mass spectrometry fo
Q trap system is a type of mass spectrometer that uses triple quadrupole technology with an added linear ion trap for enhanced sensitivity and selectivity.
Q trap system is used for targeted quantification and identification of small molecules in complex matrices.
It combines the benefits of triple quadrupole technology with an added linear ion trap for enhanced sensitivity and selectivity.
It allows for multiple reaction...
I applied via Naukri.com and was interviewed before May 2023. There were 2 interview rounds.
posted on 30 Oct 2024
I applied via LinkedIn and was interviewed before Oct 2023. There were 2 interview rounds.
Interview experience
Assistant Manager
1k
salaries
| ₹5.4 L/yr - ₹14.6 L/yr |
Executive
987
salaries
| ₹4 L/yr - ₹11 L/yr |
Officer
884
salaries
| ₹2.4 L/yr - ₹8.4 L/yr |
Senior Chemist
507
salaries
| ₹2.3 L/yr - ₹6.5 L/yr |
Deputy Manager
479
salaries
| ₹8 L/yr - ₹21 L/yr |
Sun Pharmaceutical Industries
Cipla
DRJ & CO
Biocon Limited