Tata Steel
Proud winner of ABECA 2024 - AmbitionBox Employee Choice Awards
Filter interviews by
I applied via Campus Placement
The iron-carbon diagram is a graphical representation of the phases and microstructures that form as carbon is added to iron.
The diagram shows the relationship between carbon content and the resulting microstructure of iron.
It helps in understanding the properties and behavior of different types of steel.
The diagram consists of various regions such as ferrite, pearlite, cementite, and austenite.
The eutectoid point repr...
I am a dedicated and experienced field engineer with a strong background in troubleshooting and problem-solving.
I have a Bachelor's degree in Engineering from XYZ University.
I have worked for ABC Company for 5 years, where I successfully managed various field projects.
I am proficient in using various technical tools and equipment for field work.
I have excellent communication skills and can work well in a team environme...
My goal is to continuously improve my technical skills and knowledge in the field of engineering.
Attend workshops and training sessions to learn new technologies and tools
Work on personal projects to apply and enhance my skills
Seek mentorship from experienced engineers in the industry
Top trending discussions
posted on 12 May 2022
I applied via Campus Placement and was interviewed before May 2021. There were 3 interview rounds.
Maximum questions from thermodynamics ,Som,Fluid
I applied via Naukri.com and was interviewed in Feb 2021. There was 1 interview round.
I applied via Job Portal and was interviewed in Apr 2021. There was 1 interview round.
I applied via Campus Placement and was interviewed before Jul 2021. There were 2 interview rounds.
Current affairs and technical both questions will come be ready
I applied via Company Website and was interviewed in Feb 2024. There were 2 interview rounds.
posted on 25 Dec 2023
I applied via Recruitment Consulltant and was interviewed before Dec 2022. There were 2 interview rounds.
Motor megger value should be at least twice the rated voltage of the motor. Cable size should be selected based on the full load current of the motor.
Motor megger value should be at least 2 times the rated voltage of the motor to ensure insulation integrity.
Cable size should be selected based on the full load current of the motor to prevent overheating and voltage drop.
For example, for a motor rated at 400V, the megger...
OLR value of a motor is determined by the rating of the motor and the MPCB rating.
OLR value is the Overload Relay value, which is used to protect the motor from overload conditions.
The OLR value is typically set based on the rating of the motor and the rating of the Motor Protection Circuit Breaker (MPCB).
For example, if a motor has a rating of 5 HP and the MPCB rating is 10A, the OLR value would be calculated accordin
I applied via Walk-in and was interviewed in Aug 2023. There was 1 interview round.
MCB and overload relay are both electrical protection devices, but they serve different purposes.
MCB stands for Miniature Circuit Breaker and is used to protect electrical circuits from overcurrents and short circuits.
Overload relay is used to protect motors and other electrical equipment from excessive current that can cause overheating and damage.
MCB operates based on the principle of thermal and magnetic tripping, w...
A soft starter is a device used to gradually start and stop the motor by controlling the voltage applied to it.
Soft starters are used to reduce the starting current and torque of an electric motor.
They provide a smooth and controlled acceleration and deceleration of the motor.
Soft starters can be used in various applications such as pumps, fans, and conveyor belts.
They typically consist of power electronics, control ci...
A drive is a device that reads and writes data to storage media, allowing users to access and store information.
Drives can be internal or external, such as hard disk drives (HDDs) or solid-state drives (SSDs).
They use various technologies like magnetic or flash memory to store data.
Drives are connected to a computer or device through interfaces like SATA, USB, or PCIe.
They have controllers that manage data transfer and...
Star delta starters are used to reduce the starting current of induction motors.
Star delta starters are used in applications where the starting current needs to be limited.
They are commonly used in industries where large motors are employed.
By starting the motor in star configuration, the current is reduced to one-third of the delta configuration.
This helps in preventing excessive voltage drop and reduces stress on the...
The protection of a transformer involves various measures to ensure its safe and reliable operation.
Overcurrent protection: Protects against excessive current flow.
Overvoltage protection: Guards against high voltage surges.
Under/over frequency protection: Monitors and controls the frequency of the input power.
Temperature protection: Prevents overheating by monitoring the transformer's temperature.
Buchholz relay protect...
I applied via Campus Placement and was interviewed before Jan 2022. There were 4 interview rounds.
Be confident in your answer and no more confusing. Think twice, answer Little bit similar but u have to choose one it has a more accurate. Time management is main. What time you did taken to answer for each question.
Talk short with important matter. Your voice should to audible for all.
based on 1 review
Rating in categories
Manager
1.6k
salaries
| ₹6 L/yr - ₹20 L/yr |
Assistant Manager
1.4k
salaries
| ₹5.2 L/yr - ₹14.9 L/yr |
Senior Manager
1.1k
salaries
| ₹9.2 L/yr - ₹35 L/yr |
Associate Engineer
927
salaries
| ₹2 L/yr - ₹8 L/yr |
Junior Engineer
890
salaries
| ₹2.2 L/yr - ₹10 L/yr |
JSW Steel
Jindal Steel and Power
ArcelorMittal Nippon Steel
Jindal Stainless