Tata Steel
Proud winner of ABECA 2024 - AmbitionBox Employee Choice Awards
Filter interviews by
To install an operating system, you need to boot from installation media, follow on-screen prompts, select installation options, and wait for the process to complete.
Boot from installation media (USB, DVD)
Follow on-screen prompts to start installation process
Select installation options such as language, time zone, and disk partitioning
Wait for the installation process to complete
Reboot the system after installation is
To install a printer, you need to connect it to the computer, install the necessary drivers, and set it as the default printer.
Connect the printer to the computer using a USB cable or through a network connection.
Download and install the printer drivers from the manufacturer's website or use the installation CD that came with the printer.
Go to Control Panel > Devices and Printers, click on 'Add a printer', and follow t...
To rejoin a domain, you need to access the system properties, change the computer name, and then rejoin the domain.
Access system properties by right-clicking on 'This PC' and selecting 'Properties'.
Click on 'Change settings' next to the computer name.
Click on 'Change' to rename the computer and then click 'OK'.
Click on 'Change' next to 'To rename this computer or change its domain or workgroup'.
Enter the domain name an...
RDP can be connected by using the Remote Desktop Connection tool on Windows.
Open Remote Desktop Connection tool on Windows
Enter the IP address or hostname of the remote computer
Click 'Connect' and enter the username and password of the remote computer
Click 'OK' to establish the RDP connection
To configure Ms Outlook, you need to open the application, enter your email address and password, and set up the server settings.
Open Microsoft Outlook application
Click on 'File' tab and select 'Add Account'
Enter your email address and password
Follow the prompts to set up server settings (IMAP/POP and SMTP)
Click 'Finish' to complete the configuration
Top trending discussions
posted on 18 May 2020
I applied via Naukri.com and was interviewed in Nov 2019. There were 3 interview rounds.
Control valve calibration involves adjusting the valve to ensure it operates within specified parameters.
Determine the valve's operating range and desired set points
Use a calibration bench or in-line calibration equipment to adjust the valve's position and response time
Verify the valve's performance using a flow meter or pressure gauge
Document the calibration process and results for future reference
I applied via Referral and was interviewed in Sep 2020. There was 1 interview round.
I applied via Approached by Company and was interviewed before May 2021. There were 3 interview rounds.
I applied via Referral and was interviewed in Dec 2020. There were 3 interview rounds.
Iron carbon diagram shows the relationship between carbon content and properties of steel.
The diagram helps in understanding the microstructure of steel.
It shows the different phases of steel at different carbon concentrations.
Low carbon steel has less than 0.3% carbon, while high carbon steel has more than 0.6% carbon.
Medium carbon steel has a carbon content between 0.3% and 0.6%.
The diagram also helps in determining ...
Pressure relief valve releases excess pressure to prevent damage, while pressure reducing valve reduces pressure to a desired level.
Pressure relief valve is used to protect equipment from overpressure by releasing excess pressure to the atmosphere.
Pressure reducing valve is used to reduce the pressure of a fluid to a desired level in a system.
Pressure relief valves are typically found in systems where pressure buildup ...
Hydraulic piston pumps offer higher efficiency, variable flow rates, and better control compared to fixed displacement vane pumps.
Hydraulic piston pumps have higher efficiency due to their ability to vary flow rates based on demand, reducing energy consumption.
Piston pumps provide better control over fluid flow and pressure, making them suitable for applications requiring precise operation.
Piston pumps are more durable...
I applied via Approached by Company and was interviewed before Apr 2023. There were 2 interview rounds.
No, TIA Portal is not compatible with S7-300 CPU.
TIA Portal is designed for newer Siemens PLCs like S7-1200 and S7-1500, not S7-300.
For S7-300 CPUs, Step 7 software should be used for programming.
TIA Portal offers advanced features like integrated safety, motion control, and HMI design.
S7-300 CPUs are older models with limited capabilities compared to newer PLCs.
Encoder provides digital output while resolver provides analog output.
Encoder converts mechanical motion into digital signals, resolver converts mechanical motion into analog signals.
Encoder is more accurate and provides higher resolution compared to resolver.
Resolver is more robust and reliable in harsh environments due to lack of sensitive electronics.
Examples: Encoder - optical encoder, magnetic encoder. Resolver -
I applied via Walk-in and was interviewed before Jan 2022. There were 3 interview rounds.
based on 3 interviews
Interview experience
based on 3 reviews
Rating in categories
Manager
1.6k
salaries
| ₹6 L/yr - ₹20.1 L/yr |
Assistant Manager
1.4k
salaries
| ₹5.2 L/yr - ₹18 L/yr |
Senior Manager
1.1k
salaries
| ₹9.1 L/yr - ₹35 L/yr |
Associate Engineer
914
salaries
| ₹2 L/yr - ₹8 L/yr |
Junior Engineer
910
salaries
| ₹2.4 L/yr - ₹10 L/yr |
JSW Steel
Jindal Steel and Power
ArcelorMittal Nippon Steel
Jindal Stainless