Filter interviews by
Be the first one to contribute and help others!
I applied via Recruitment Consulltant and was interviewed in Nov 2024. There were 2 interview rounds.
posted on 11 Jul 2024
It was a test taken on same day which has only 1 english questions rest all were of reasoning and quants,45 min test .
They will ask you to write a Letter which I think they don't even read
I applied via Naukri.com and was interviewed in Dec 2023. There was 1 interview round.
Yes, I have knowledge and experience in sales.
I have experience in prospecting, qualifying, and closing sales deals.
I am familiar with sales techniques such as consultative selling and solution selling.
I understand the importance of building relationships with customers to drive sales.
I have experience in creating and delivering sales presentations to potential clients.
I am skilled in negotiating and overcoming objecti...
I applied via Naukri.com and was interviewed in Apr 2024. There was 1 interview round.
I applied via Approached by Company and was interviewed in Sep 2023. There were 2 interview rounds.
Open loop does not have feedback mechanism, while closed loop does.
Open loop system does not have a feedback mechanism to adjust the output based on the input.
Closed loop system uses feedback from the output to control the input and maintain desired output.
Open loop systems are simpler and less accurate, while closed loop systems are more complex but more accurate.
Example: A toaster is an open loop system as it does no...
The equation of a PID controller is a control loop feedback mechanism used in industrial control systems.
The equation for a PID controller is: u(t) = Kp*e(t) + Ki*∫e(t)dt + Kd*de(t)/dt
Kp, Ki, and Kd are the proportional, integral, and derivative gains respectively
The proportional term Kp reacts to the current error value
The integral term Ki reacts to the accumulation of past errors
The derivative term Kd reacts to the r
Two common pressure sensors are piezoresistive sensors and capacitive sensors.
Piezoresistive sensors: measure pressure by changes in electrical resistance
Capacitive sensors: measure pressure by changes in capacitance
Open loop does not have feedback mechanism, while closed loop does.
Open loop system does not have a feedback mechanism to adjust the output based on the input.
Closed loop system uses feedback from the output to adjust the input and maintain desired output.
Examples of open loop systems include a toaster or a washing machine with a timer setting.
Examples of closed loop systems include a thermostat controlling room temper
The pitch of a ballscrew can be measured by counting the number of threads per unit length.
Measure the distance between two adjacent threads on the ballscrew.
Count the number of threads within that distance.
Divide the distance by the number of threads to calculate the pitch.
Pitch = Distance / Number of threads
based on 19 reviews
Rating in categories
Senior HR Executive
5
salaries
| ₹3.5 L/yr - ₹4.5 L/yr |
Production Engineer
4
salaries
| ₹1.8 L/yr - ₹3 L/yr |
Assistant Manager- Purchase
4
salaries
| ₹6 L/yr - ₹6.5 L/yr |
Site Engineer Mechanical
4
salaries
| ₹1.8 L/yr - ₹2.8 L/yr |
Civil Engineer
4
salaries
| ₹3 L/yr - ₹4.5 L/yr |
Falcon Autotech
Technosoft Engineering Projects Limited
Festo
TMEIC