I applied via Newspaper Ad and was interviewed in Apr 2022. There were 4 interview rounds.
Calibration of GC is a process of adjusting the instrument to ensure accurate and precise measurements.
Calibration should be performed regularly to maintain accuracy.
The process involves comparing the instrument's readings to known standards.
Adjustments are made to the instrument's settings to match the known standards.
Documentation of calibration should be kept for quality control purposes.
Examples of standards used f...
GC troubleshooting involves identifying and resolving issues with the gas chromatography system.
Check for leaks in the system
Verify the column is properly installed and conditioned
Ensure the detector is functioning correctly
Calibrate the instrument regularly
Check for contamination in the sample or column
Inspect the inlet liner and septum for damage or buildup
Review the method parameters for accuracy and precision
Top trending discussions
I applied via Campus Placement and was interviewed before Jan 2021. There were 2 interview rounds.
Basic test
I applied via Recruitment Consulltant and was interviewed in Feb 2022. There were 5 interview rounds.
Gas chromatography is a technique used to separate and analyze volatile compounds in a mixture.
Gas chromatography involves the use of a stationary phase and a mobile phase.
The stationary phase is a solid or liquid coating inside a column, while the mobile phase is a gas.
The mixture is injected into the column, and as the mobile phase flows through, different compounds interact with the stationary phase at different rat...
Buffer solutions with known pH values are used for pH meter calibration.
Buffer solutions with pH values of 4.01, 7.00, and 10.01 are commonly used for pH meter calibration.
The choice of buffer solution depends on the pH range of the sample being tested.
The buffer solutions should be stored properly and replaced regularly to ensure accurate calibration.
Calibration should be performed before each use of the pH meter.
Total productivity Maintenance
Handling of HPLC GC and all other instruments used in Quality control department
I applied via Referral and was interviewed before Dec 2021. There were 2 interview rounds.
I applied via Job Fair and was interviewed before Jun 2021. There were 3 interview rounds.
I applied via Recruitment Consultant and was interviewed before Oct 2020. There was 1 interview round.
I have extensive experience in using various piping design tools.
Proficient in using AutoCAD for piping design
Familiar with 3D modeling software like SolidWorks for creating detailed piping layouts
Skilled in using piping design software such as Caesar II for stress analysis
Experience in using PDMS (Plant Design Management System) for piping design and layout
Knowledge of industry standards and codes related to piping de
posted on 13 Oct 2021
I applied via Referral and was interviewed before Oct 2020. There were 4 interview rounds.
I applied via Recruitment Consultant and was interviewed in May 2021. There were 4 interview rounds.
I applied via Approached by Company and was interviewed before Jan 2022. There were 3 interview rounds.
based on 11 reviews
Rating in categories
Junior Engineer
992
salaries
| ₹2 L/yr - ₹10 L/yr |
Senior Executive
421
salaries
| ₹4.5 L/yr - ₹15.2 L/yr |
Junior Officer
191
salaries
| ₹2.5 L/yr - ₹9 L/yr |
Assistant Manager
189
salaries
| ₹7.1 L/yr - ₹16 L/yr |
Technician
185
salaries
| ₹2.4 L/yr - ₹6.6 L/yr |
Asian Paints
Berger Paints
Pidilite Industries
Kansai Nerolac Paints