Filter interviews by
I applied via Walk-in and was interviewed in Aug 2023. There was 1 interview round.
Reactor mechanical seal assembly work involves installing, maintaining, and troubleshooting mechanical seals in reactor systems.
Understanding the components of a mechanical seal assembly
Properly installing and aligning the mechanical seal
Performing routine maintenance on the seal to prevent leaks
Troubleshooting issues such as leaks or malfunctions
Following safety protocols when working with reactor systems
Dial gauge alignment work involves ensuring the accuracy of measurements by adjusting the position of the gauge.
Ensure the dial gauge is securely mounted to a stable surface
Use a calibration standard to check the accuracy of the gauge
Adjust the position of the gauge by loosening the mounting screws and realigning as needed
Verify the accuracy of the gauge after realignment
Possible causes of vacuum pump vacuum problem and troubleshooting steps
Check for leaks in the vacuum system
Inspect the vacuum pump for any damage or wear
Ensure the pump is properly lubricated
Check the vacuum pump's inlet filter for clogs
Verify that the pump is receiving adequate power supply
I applied via Walk-in and was interviewed in Dec 2020. There was 1 interview round.
Glass line reactor mechanical seal fitting parameters are critical for ensuring proper functioning and preventing leaks.
The fitting parameters depend on the type of mechanical seal being used.
Factors such as seal face material, seal face loading, and seal face geometry must be considered.
Proper installation and alignment of the mechanical seal is also important.
Regular maintenance and monitoring of the seal is necessar...
SRF interview questions for designations
posted on 18 Oct 2021
I applied via Walk-in
I applied via Recruitment Consultant and was interviewed before Oct 2020. There was 1 interview round.
I have extensive experience in using various piping design tools.
Proficient in using AutoCAD for piping design
Familiar with 3D modeling software like SolidWorks for creating detailed piping layouts
Skilled in using piping design software such as Caesar II for stress analysis
Experience in using PDMS (Plant Design Management System) for piping design and layout
Knowledge of industry standards and codes related to piping de
posted on 13 Oct 2021
I applied via Referral and was interviewed before Oct 2020. There were 4 interview rounds.
posted on 6 Mar 2020
Mcb stands for Miniature Circuit Breaker and MCCB stands for Molded Case Circuit Breaker.
Mcb is a type of circuit breaker that is used for low voltage applications.
MCCB is a type of circuit breaker that is used for high voltage applications.
Both Mcb and MCCB are used to protect electrical circuits from overloads and short circuits.
Mcb is usually rated for currents up to 100 amps, while MCCB can handle currents up to 25...
Current and voltage are two fundamental concepts in electricity. Current is the flow of electric charge, while voltage is the potential difference that drives the flow.
Current is the rate of flow of electric charge, measured in amperes (A).
Voltage is the force or pressure that pushes the electric charge to flow, measured in volts (V).
Current flows through a conductor, while voltage exists across a conductor.
Current is ...
A unit is a standard measurement used to quantify physical quantities. Current is measured in amperes (A) and voltage is measured in volts (V).
A unit is a fixed quantity used as a standard of measurement.
Current is the flow of electric charge in a circuit and is measured in amperes (A).
Voltage is the electric potential difference between two points in a circuit and is measured in volts (V).
The unit of current, ampere, ...
There are several types of transformers used in electrical systems.
Power Transformers
Distribution Transformers
Instrument Transformers
Auto Transformers
Isolation Transformers
Step-up and Step-down Transformers
Three-phase Transformers
Single-phase Transformers
D.OL starter is a type of motor starter used to start and stop three-phase motors.
D.OL stands for Direct-On-Line.
It is the simplest and most common type of motor starter.
It directly connects the motor to the power supply, providing full voltage to the motor.
It is suitable for small to medium-sized motors.
It does not provide any protection against overloading or short circuits.
It is commonly used in applications such as
An ampere (amp) is the unit of electric current in the International System of Units (SI).
Amperes measure the rate of flow of electric charge.
It is named after the French physicist André-Marie Ampère.
One ampere is defined as one coulomb of charge passing through a point in one second.
Amperes are used to measure the current flowing through electrical circuits.
Common household appliances like light bulbs and refrigerator...
I appeared for an interview before Mar 2022.
A protection system is a set of devices and measures designed to prevent damage or harm to equipment, personnel, or the environment in case of a fault or abnormal condition.
Protection systems can include circuit breakers, fuses, relays, and alarms.
They are commonly used in electrical systems to prevent overloads, short circuits, and ground faults.
Protection systems are essential for ensuring the safety and reliability ...
based on 5 interviews
2 Interview rounds
based on 23 reviews
Rating in categories
Junior Engineer
989
salaries
| ₹2.1 L/yr - ₹9.4 L/yr |
Senior Executive
415
salaries
| ₹4.5 L/yr - ₹15.2 L/yr |
Junior Officer
191
salaries
| ₹2.5 L/yr - ₹9 L/yr |
Technician
185
salaries
| ₹2.4 L/yr - ₹6.6 L/yr |
Assistant Manager
169
salaries
| ₹7.3 L/yr - ₹16 L/yr |
Asian Paints
Berger Paints
Pidilite Industries
Kansai Nerolac Paints