Filter interviews by
I applied via Recruitment Consulltant and was interviewed before Feb 2023. There were 2 interview rounds.
posted on 10 Oct 2024
I applied via Referral and was interviewed in Sep 2024. There was 1 interview round.
Transformer vector group is a method used to represent the phase shift between the primary and secondary windings of a transformer.
Transformer vector group indicates the relationship between the primary and secondary winding phases.
It helps in determining the connection and phase shift of the transformer windings.
Common vector groups include Yy0, Yd1, Dyn11, etc.
Vector group is important for parallel operation of trans
VBD test is conducted in transformers to ensure insulation integrity and detect any potential faults.
VBD test helps in identifying any weak spots in the insulation of the transformer
It helps in preventing breakdowns and ensuring the safety and reliability of the transformer
By conducting VBD test, any potential faults can be detected early and necessary maintenance can be carried out
It is a standard procedure in transfo
I applied via Walk-in and was interviewed in Aug 2024. There was 1 interview round.
33 kV to 220 SLD refers to a switchgear system for electrical distribution at medium voltage levels.
33 kV to 220 SLD likely refers to a switchgear system designed to handle voltages between 33 kV and 220 kV.
SLD stands for Single Line Diagram, which is a schematic representation of the electrical distribution system.
This switchgear system would be used for distributing electricity from a higher voltage transmission syst...
ACB stands for Air Circuit Breaker and VCB stands for Vacuum Circuit Breaker.
ACB is a type of circuit breaker that operates in the air where the arc is drawn in the air and extinguished using air.
VCB is a type of circuit breaker that operates in a vacuum where the arc is drawn in a vacuum and extinguished using vacuum.
ACBs are commonly used in low voltage applications while VCBs are used in medium voltage applications.
...
I was interviewed in Aug 2023.
I applied via Naukri.com
posted on 23 May 2021
I applied via Walk-in and was interviewed in Apr 2022. There were 3 interview rounds.
I applied via Approached by Company and was interviewed before Apr 2023. There were 2 interview rounds.
I have 5 years of experience working with mechanical boilers in industrial settings.
Operated and maintained mechanical boilers to ensure efficient and safe operation
Performed regular inspections and maintenance tasks to prevent breakdowns
Troubleshooted and repaired boiler issues as needed
Ensured compliance with safety regulations and protocols
Trained new staff on boiler operation and maintenance procedures
posted on 11 Jun 2021
We are delivering electrical products and equipment for various industries and applications.
Our products include transformers, switchgear, motors, and control panels.
We provide electrical solutions for industries such as manufacturing, construction, and energy.
Our equipment is responsible for powering machinery, lighting, and other electrical systems.
We ensure that all our products meet safety standards and are install...
I was interviewed in Mar 2024.
I have 8 years of experience working as a Shift Engineer in various industries.
I have 8 years of experience as a Shift Engineer
Worked in various industries such as manufacturing, energy, and facilities management
Experience in troubleshooting, maintenance, and operation of equipment
Familiar with safety regulations and protocols
Led teams in shift operations and coordinated with other departments
We used air circuit breakers in my previous company.
We used air circuit breakers for their reliability and ease of maintenance.
Air circuit breakers are commonly used in industrial settings for their high breaking capacity.
Examples of air circuit breaker brands we used include Siemens and Schneider Electric.
Circuit breaker rating refers to the maximum current that the breaker can safely interrupt without causing damage.
Circuit breaker rating is typically expressed in amps (e.g. 15A, 20A, 30A).
The rating should be chosen based on the maximum current that will flow through the circuit.
It is important to select a circuit breaker with a rating higher than the maximum current to prevent tripping.
Using a circuit breaker with a ...
Cycle breaker maintenance involves regular inspection, testing, and replacement of components to ensure proper functioning.
Inspecting for signs of wear or damage
Testing functionality with appropriate equipment
Replacing faulty components as needed
Following manufacturer's guidelines for maintenance schedule
Keeping detailed records of maintenance activities
based on 3 reviews
Rating in categories
Facility Executive
213
salaries
| ₹1.8 L/yr - ₹5.3 L/yr |
Assistant Manager
201
salaries
| ₹2.8 L/yr - ₹10.2 L/yr |
Facility Manager
201
salaries
| ₹4.8 L/yr - ₹13 L/yr |
Shift Engineer
184
salaries
| ₹1.8 L/yr - ₹8 L/yr |
Assistant Facility Manager
171
salaries
| ₹2.7 L/yr - ₹9 L/yr |
Compass Group Support Services
Aramark
CBRE
Cushman & Wakefield