i
Smartworks
Filter interviews by
I applied via Naukri.com and was interviewed in Jan 2022. There were 2 interview rounds.
Top trending discussions
I applied via Referral and was interviewed in Mar 2024. There was 1 interview round.
Seeking new challenges and growth opportunities in a larger organization.
Desire for career advancement
Limited growth opportunities in current company
Seeking new challenges and projects
Company restructuring or changes in management
I expect opportunities for growth, challenging projects, supportive team, and fair compensation.
Opportunities for career advancement
Challenging and interesting projects to work on
Supportive and collaborative team environment
Fair and competitive compensation package
posted on 14 Mar 2024
I applied via Naukri.com and was interviewed in Feb 2024. There was 1 interview round.
Discuss about experience
I applied via Naukri.com and was interviewed in Dec 2022. There were 3 interview rounds.
About high rise buildings and construction
posted on 18 May 2023
I applied via Naukri.com and was interviewed before May 2022. There were 2 interview rounds.
Automatic sprinkler system, Hydrant system and FAPA system are fire protection systems used in buildings.
Automatic sprinkler system is a fire suppression system that uses water to extinguish fires. It consists of a network of pipes with sprinkler heads that activate when heat is detected.
Hydrant system is a fire protection system that uses water from a pressurized source to extinguish fires. It consists of a network of...
Different types of pipes are used in PHE systems depending on the application and fluid being transported.
Common types of pipes used in PHE systems include copper, PVC, CPVC, PEX, and galvanized steel.
Copper pipes are often used for hot and cold water supply lines due to their durability and resistance to corrosion.
PVC and CPVC pipes are commonly used for drainage and waste systems due to their affordability and ease o...
There are two types of water supply systems - direct and indirect.
Direct water supply system - water is supplied directly from the mains to the point of use without any storage tank.
Indirect water supply system - water is stored in a tank and then supplied to the point of use through pipes.
Direct systems are commonly used in high-rise buildings while indirect systems are used in low-rise buildings.
Direct systems are mo...
Basement mechanical ventilation system is designed to remove stale air and moisture from the basement and replace it with fresh air.
The system consists of an exhaust fan that pulls out stale air and moisture from the basement.
Fresh air is brought in through an intake vent or duct.
The system may also include a dehumidifier to control moisture levels.
Proper maintenance is important to ensure the system functions effectiv
posted on 25 Mar 2023
I applied via Naukri.com and was interviewed before Mar 2022. There were 2 interview rounds.
The area of projects and types of projects I have worked on vary greatly.
I have worked on projects in various industries including construction, healthcare, and technology.
Types of projects I have worked on include software development, building construction, and medical equipment installation.
I am adaptable and able to quickly learn about new industries and project types.
I have experience working on both small and lar
posted on 31 Mar 2022
posted on 5 Mar 2022
I applied via Company Website and was interviewed in Sep 2021. There were 3 interview rounds.
I applied via Referral and was interviewed in Mar 2024. There was 1 interview round.
Seeking new challenges and growth opportunities in a larger organization.
Desire for career advancement
Limited growth opportunities in current company
Seeking new challenges and projects
Company restructuring or changes in management
I expect opportunities for growth, challenging projects, supportive team, and fair compensation.
Opportunities for career advancement
Challenging and interesting projects to work on
Supportive and collaborative team environment
Fair and competitive compensation package
FDD field dry density test is a method to determine the density of soil in the field.
FDD stands for Field Dry Density.
It is a test conducted on soil to measure its density.
The test involves extracting a soil sample from the field and determining its dry weight and volume.
The dry density is calculated by dividing the dry weight of the soil sample by its volume.
This test helps in assessing the compaction and quality of s
The slump in column concreting should be between 150-175 mm.
The slump should be measured before pouring the concrete.
The slump should be consistent throughout the column.
The slump should not exceed 175 mm to avoid segregation.
The slump should not be less than 150 mm to ensure proper compaction.
The slump can be adjusted by adding water or admixtures.
The slump test should be performed according to ASTM standards.
Slump in column concreting 90 to 100 mm
Slump refers to the consistency of the concrete mix
A slump of 90 to 100 mm indicates a very wet and unstable mix
This can lead to issues with the structural integrity of the column
Possible causes include incorrect water-cement ratio or improper mixing
Solutions may include adjusting the mix proportions or using additives to improve stability
Operations Executive
84
salaries
| ₹3 L/yr - ₹5.2 L/yr |
Assistant Manager Operations
48
salaries
| ₹3.9 L/yr - ₹8.5 L/yr |
IT Executive
42
salaries
| ₹2.8 L/yr - ₹5.5 L/yr |
Inventory Executive
41
salaries
| ₹2.3 L/yr - ₹4.9 L/yr |
assistant community manager
34
salaries
| ₹3.2 L/yr - ₹6.3 L/yr |
Regus
WeWork India Management
Cowrks
91springboard