FDD field dry density test is a method to determine the density of soil in the field.
FDD stands for Field Dry Density.
It is a test conducted on soil to measure its density.
The test involves extracting a soil sample from the field and determining its dry weight and volume.
The dry density is calculated by dividing the dry weight of the soil sample by its volume.
This test helps in assessing the compaction and quality of s
The slump in column concreting should be between 150-175 mm.
The slump should be measured before pouring the concrete.
The slump should be consistent throughout the column.
The slump should not exceed 175 mm to avoid segregation.
The slump should not be less than 150 mm to ensure proper compaction.
The slump can be adjusted by adding water or admixtures.
The slump test should be performed according to ASTM standards.
Slump in column concreting 90 to 100 mm
Slump refers to the consistency of the concrete mix
A slump of 90 to 100 mm indicates a very wet and unstable mix
This can lead to issues with the structural integrity of the column
Possible causes include incorrect water-cement ratio or improper mixing
Solutions may include adjusting the mix proportions or using additives to improve stability
Top trending discussions
I applied via Recruitment Consulltant and was interviewed before Sep 2021. There was 1 interview round.
I applied via Approached by Company and was interviewed before Mar 2023. There were 2 interview rounds.
I applied via Approached by Company and was interviewed in Dec 2022. There were 2 interview rounds.
OSHR design specification includes hardware and software requirements for the system.
Hardware requirements such as processor, memory, storage, and input/output devices.
Software requirements such as operating system, programming languages, and development tools.
Functional requirements such as user interface, data storage, and security features.
Non-functional requirements such as performance, reliability, and scalability...
The full form of FHTC is not clear. HDPE pipes have high strength and flexibility, while DI pipes are more durable. Wall thickness of water retaining structure depends on the design and load requirements.
FHTC full form is not clear
HDPE pipes have high strength and flexibility, making them suitable for underground installations and areas with high seismic activity
DI pipes are more durable and have a longer lifespan, mak...
The minimum required Sbc for raft foundation design of OHSR depends on various factors.
The size and weight of the OHSR
The soil type and bearing capacity
The depth of the foundation
The seismic zone of the location
Consulting a geotechnical engineer is recommended
The code of practice used for water retaining structures is BS EN 1992-3:2006.
BS EN 1992-3:2006 is the European standard for the design of concrete structures.
It provides guidelines for the design, construction, and maintenance of water retaining structures.
The code covers various types of water retaining structures such as reservoirs, tanks, and swimming pools.
It includes requirements for materials, structural design,...
English, Quant, Analytical
I applied via Approached by Company and was interviewed before Oct 2022. There were 2 interview rounds.
I have a proven track record of working independently and effectively managing client relationships.
Demonstrate past experience of successfully managing projects independently
Highlight strong communication skills in dealing with clients
Show ability to prioritize tasks and meet deadlines without constant supervision
I applied via Approached by Company and was interviewed in Jan 2024. There were 5 interview rounds.
Online based test on basic aptitude and problem solving tests.
I applied via Naukri.com and was interviewed in May 2022. There was 1 interview round.
To solve construction problems, quality, safety, progress, and time schedule, a project manager should prioritize communication, risk management, and continuous improvement.
Establish clear communication channels with all stakeholders
Identify potential risks and develop contingency plans
Regularly review and improve quality control processes
Ensure compliance with safety regulations and provide training to workers
Monitor
based on 1 interview
Interview experience
Junior Engineer
157
salaries
| ₹2 L/yr - ₹5.4 L/yr |
Senior Engineer
94
salaries
| ₹3.8 L/yr - ₹10.5 L/yr |
Junior Engineer Civil
81
salaries
| ₹2 L/yr - ₹5.4 L/yr |
Civil Engineer
34
salaries
| ₹2.7 L/yr - ₹6.4 L/yr |
Safety Officer
34
salaries
| ₹2.5 L/yr - ₹7.6 L/yr |
Knight Frank
R.S. Infraprojects
SMEC
BPTP