Filter interviews by
RCC column cover is used to protect the reinforcement bars from environmental factors and provide a finished look.
RCC column cover helps in preventing corrosion of reinforcement bars due to exposure to moisture, chemicals, and other elements.
It also enhances the aesthetic appeal of the structure by providing a smooth and finished surface.
RCC column covers can be made using materials like concrete, plaster, or cladding.
...
RCC beams are used for providing support to bent up bars in a reinforced concrete structure.
RCC beams are designed to carry the load of the structure and transfer it to the columns or walls.
Bent up bars are used to provide additional strength and prevent shear failure in the structure.
The bent up bars are typically placed at the bottom of the beam to resist tension forces.
By using RCC beams for bent up bars, the overal...
I applied via Job Portal and was interviewed in Jun 2023. There were 2 interview rounds.
GD topic is cinema is threat for Indian culture
Isolators are devices used to disconnect a circuit from the power source, while circuit breakers are devices used to protect the circuit from overloads and short circuits.
Isolators are used for isolating a circuit from the power source for maintenance or repair purposes.
Circuit breakers are used to protect the circuit from overloads and short circuits by automatically breaking the circuit when necessary.
Isolators are t...
I was interviewed before Apr 2022.
Standard topics on ethics, corruption, bribe etc
Top trending discussions
I applied via Recruitment Consultant and was interviewed in Dec 2021. There was 1 interview round.
Transformers are rated in KVA because it represents the apparent power they can handle.
KVA stands for kilovolt-ampere, which is a unit of apparent power.
Transformers are designed to handle a certain amount of power, and the KVA rating indicates their capacity.
The KVA rating takes into account both the voltage and current that the transformer can handle.
It helps in determining the appropriate size and capacity of the tr...
The ground clearance of a 400KV transmission line varies depending on various factors.
The ground clearance of a transmission line is the vertical distance between the lowest point of the conductor and the ground.
The ground clearance is determined based on safety regulations and requirements.
Factors that influence the ground clearance include terrain, vegetation, and proximity to buildings or roads.
In hilly areas, the g...
The tan Delta value of electrical equipment should be as low as possible.
Tan Delta is a measure of the dielectric losses in electrical equipment.
A low tan Delta value indicates that the equipment has good insulation properties.
The tan Delta value can be affected by factors such as temperature, moisture, and aging of the equipment.
For transformers, a typical tan Delta value is around 0.001 or lower.
ACSRinvar conductors are widely used in metro principal cities due to their high strength and low thermal expansion.
ACSRinvar conductors have a high tensile strength, making them suitable for long-distance transmission lines in metro cities.
They have a low coefficient of thermal expansion, which helps in reducing sagging of the conductors and maintaining power transmission efficiency.
The use of ACSRinvar conductors in ...
The Basis setting of REF protection for a transformer should be determined based on the transformer's characteristics and the system requirements.
The basis setting of REF (Restricted Earth Fault) protection for a transformer is typically determined by considering the transformer's winding configuration, impedance, and the system's fault level.
The setting should be chosen to ensure that the protection operates reliably ...
The SF6 gas used for Ckt breaker chamber should be maintained at a pressure of around 5-7 bar.
The SF6 gas in the circuit breaker chamber should be maintained at a specific pressure to ensure proper functioning.
The recommended pressure for SF6 gas in the circuit breaker chamber is typically between 5 and 7 bar.
Maintaining the correct pressure helps in extinguishing the arc during circuit interruption.
Too low or too high...
Star-star zero phase shift transformer windings are used to provide a balanced three-phase output with zero phase shift between primary and secondary voltages.
Star-star zero phase shift transformer windings are commonly used in power distribution systems.
They are used to supply power to three-phase loads such as motors, generators, and transformers.
The windings are designed in such a way that the voltages in the primar...
AIS and GIS substations differ in their construction and insulation methods.
AIS (Air Insulated Substation) uses air as the insulation medium, while GIS (Gas Insulated Substation) uses SF6 gas.
AIS substations require larger land areas compared to GIS substations.
GIS substations are more compact and can be installed in urban areas where space is limited.
AIS substations are more susceptible to environmental factors like p...
Vibration dampers are used with conductors to reduce the risk of fatigue failure and damage caused by wind-induced vibrations.
Vibration dampers absorb and dissipate the energy generated by wind-induced vibrations in conductors.
They help to reduce the risk of fatigue failure and damage to the conductor and associated hardware.
Vibration dampers are typically installed at regular intervals along the length of the conducto...
The main function of LA in a substation is to protect electrical equipment from lightning strikes.
LA stands for Lightning Arrester.
It is installed in substations to divert lightning strikes away from sensitive equipment.
LA provides a low-impedance path for lightning current to flow to the ground.
It helps in preventing damage to transformers, circuit breakers, and other electrical devices.
LA operates by ionizing the air...
posted on 14 May 2024
posted on 3 Mar 2024
I applied via Approached by Company
Transformer works on the principle of electromagnetic induction to transfer electrical energy between two or more circuits.
Transformers have two coils of wire, known as primary and secondary coils.
When an alternating current flows through the primary coil, it creates a changing magnetic field.
This changing magnetic field induces a voltage in the secondary coil, transferring electrical energy.
Transformers are used to st...
Factors affecting power plant efficiency include type of fuel, technology used, maintenance, and operating conditions.
Type of fuel used (coal, natural gas, nuclear, etc.)
Technology used in the power plant (combined cycle, cogeneration, etc.)
Maintenance practices (regular maintenance vs. neglect)
Operating conditions (temperature, pressure, load demand)
Efficiency of heat transfer processes
Size and age of the power plant
E...
I applied via Naukri.com and was interviewed in Aug 2023. There was 1 interview round.
MS safety valve is a device used to prevent overpressure in a system.
MS safety valve is typically installed in pipelines, vessels, or equipment to protect against excessive pressure.
When the pressure exceeds the set limit, the valve opens to release the excess pressure and prevent damage to the system.
The valve is designed to automatically close once the pressure returns to a safe level.
MS safety valves are commonly us...
Information of transformer , switchgear, electrical safety rules , Indian constitution rules of electricity.
Switchgear types include air-insulated, gas-insulated, and hybrid switchgear. Basic operation involves controlling electrical power flow.
Air-insulated switchgear uses air as the insulation medium
Gas-insulated switchgear uses sulfur hexafluoride (SF6) gas as the insulation medium
Hybrid switchgear combines air-insulated and gas-insulated switchgear
Switchgear operates by controlling the flow of electrical power
Switchgear ...
Different types of transformers and their ratings in kV. Explanation of LV and HV sides.
Transformers: Power, Distribution, Auto, Isolation, Instrument, etc.
Ratings: 1 kV, 11 kV, 33 kV, 66 kV, 132 kV, 220 kV, 400 kV, etc.
LV side: Low Voltage side of transformer, typically below 1 kV.
HV side: High Voltage side of transformer, typically above 1 kV.
LV side is used for distribution while HV side is used for transmission.
LV ...
based on 6 interviews
Interview experience
Graduate Apprentice Trainee
12
salaries
| ₹0 L/yr - ₹0 L/yr |
Executive Trainee
7
salaries
| ₹0 L/yr - ₹0 L/yr |
Apprentice
6
salaries
| ₹0 L/yr - ₹0 L/yr |
Apprenticeship Trainee
5
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Manager
5
salaries
| ₹0 L/yr - ₹0 L/yr |
NTPC
Power Grid Corporation of India
Tata Power
Adani Power