A substation is a facility used for transforming voltage levels in an electrical power system.
Substations receive high voltage electricity from power plants or transmission lines
They transform the voltage to a lower level for distribution to homes and businesses
Substations may also include equipment for protection, control, and monitoring of the power system
Transformers are classified based on their construction and cooling methods, such as dry-type, oil-filled, and cast resin transformers.
Transformers can be classified as dry-type, oil-filled, or cast resin based on their construction and cooling methods.
Dry-type transformers use air as the cooling medium and are suitable for indoor applications.
Oil-filled transformers use oil as the cooling medium and are commonly used ...
1 angle and 2 angle are terms used in engineering design to describe the orientation of a part or feature relative to a reference surface.
1 angle refers to a feature that is oriented parallel to the primary datum plane
2 angle refers to a feature that is oriented perpendicular to the primary datum plane
These terms are commonly used in geometric dimensioning and tolerancing (GD&T) to specify the orientation of features o...
Geometry and tolerance in design refer to the dimensions and allowable variations in a part or product.
Geometry refers to the shape and size of a part or product.
Tolerance is the allowable variation in dimensions to ensure proper fit and function.
Tolerances are specified using symbols like +, -, or a range of values.
For example, a hole may have a diameter of 10mm with a tolerance of +/- 0.1mm.
Tolerances can affect the
1 angle and 2 angle are terms used in engineering to describe the orientation of a part or feature in relation to a reference plane.
1 angle refers to the orientation of a part or feature with respect to one reference plane
2 angle refers to the orientation of a part or feature with respect to two reference planes
These terms are commonly used in engineering drawings to specify the orientation of features for manufacturin
posted on 2 Feb 2025
posted on 13 Jun 2024
I applied via Referral and was interviewed in Apr 2023. There were 4 interview rounds.
Basic questions based on transformer, LT distribution, current affairs, electrical protection
Transformer parts include core, windings, and insulation. Core provides magnetic path, windings carry current, insulation prevents short circuits.
Core: Provides magnetic path for flux to flow through
Windings: Carry current and induce voltage
Insulation: Prevents short circuits between windings and core
Examples: E-core, C-core, shell-type transformer
Miniature Circuit Breakers (MCBs) are types of circuit breakers used in electrical systems to protect against overcurrent and short circuits.
MCBs are classified based on their breaking capacity, rated current, and number of poles.
Common types of MCBs include Type B (standard), Type C (medium delay), and Type D (high delay).
MCBs can also be classified based on their tripping curve, such as Type K (fast tripping) and Typ
Relay is an electromechanical device used to control high power electrical devices, while MCB is a circuit protection device that trips in case of overload or short circuit.
Relay is used to control high power electrical devices by opening or closing contacts based on input signals.
MCB is a circuit protection device that trips and cuts off power in case of overload or short circuit.
Relays are electromechanical devices w...
I applied via Approached by Company and was interviewed before Dec 2023. There was 1 interview round.
I have 8 years of work experience in electrical engineering.
8 years of experience in electrical engineering
Specialized in power systems and renewable energy
Worked on projects involving circuit design and testing
Experience with CAD software for designing electrical systems
Different types of circuit breakers include thermal, magnetic, and hybrid.
Thermal circuit breakers operate based on temperature rise caused by excessive current flow.
Magnetic circuit breakers operate based on the strength of the magnetic field generated by current flow.
Hybrid circuit breakers combine features of both thermal and magnetic circuit breakers.
Other types include oil circuit breakers, air circuit breakers, a
posted on 26 Apr 2023
I applied via LinkedIn and was interviewed in Oct 2022. There were 3 interview rounds.
Telecom fibres are mainly of two types: single-mode and multi-mode. Connectors include SC, LC, ST, and FC.
Single-mode fibres have a smaller core and are used for long-distance communication.
Multi-mode fibres have a larger core and are used for short-distance communication.
SC (Subscriber Connector) and LC (Lucent Connector) are small form-factor connectors.
ST (Straight Tip) and FC (Ferrule Connector) are older connector...
based on 4 reviews
Rating in categories
Assistant Manager
26
salaries
| ₹4 L/yr - ₹12 L/yr |
Senior Engineer
25
salaries
| ₹4.1 L/yr - ₹7.1 L/yr |
AC Technician
14
salaries
| ₹1.7 L/yr - ₹3 L/yr |
Production Engineer
13
salaries
| ₹2.5 L/yr - ₹4.8 L/yr |
Deputy Manager
11
salaries
| ₹4.7 L/yr - ₹12 L/yr |
Blue Star
Voltas
Godrej Appliances
Whirlpool