Filter interviews by
I applied via Referral and was interviewed in Feb 2021. There were 4 interview rounds.
A tower crane is a type of crane used in construction to lift heavy materials and equipment to great heights.
Tower cranes are typically used in high-rise building construction.
They have a long horizontal jib with a hook on the end that can be raised and lowered.
The crane is mounted on a large concrete base that is anchored to the ground.
The operator sits in a cab at the top of the crane and controls its movements.
Tower...
I applied via Naukri.com and was interviewed in Jun 2022. There were 2 interview rounds.
ATS stands for Automatic Transfer Switch. It is used to transfer power supply between two sources. Transformer and motor maintenance procedures and protection methods are essential for their efficient operation. SAP is a software used for enterprise resource planning.
ATS is used to automatically switch power supply between two sources, ensuring uninterrupted power supply.
Transformer maintenance involves regular inspect...
HT motor rating is the maximum power it can handle and FLC is the current it draws at full load.
HT motor rating is expressed in kilowatts (kW) or megawatts (MW).
FLC of HT motor is the full load current it draws at rated voltage and frequency.
FLC is expressed in amperes (A) and varies depending on the motor's power rating and efficiency.
For example, a 1 MW HT motor may have a FLC of 1000 A at 11 kV.
The rating and FLC of...
Plant EHT system and single line diagram of plants.
EHT system refers to Extra High Tension system used in power plants
Single line diagram shows the electrical connections between different components
It is important to have a clear and accurate diagram for safety and maintenance purposes
Electrical project and ups and battery kva rating amp.
Electrical site engg and ups and servostablizer and solar panel
About electrical work
I applied via Naukri.com and was interviewed before Feb 2022. There were 3 interview rounds.
SAP procedure for UPS vendor is a process for managing vendor data in the SAP system.
The SAP procedure for UPS vendor involves creating and maintaining vendor master data in the system.
It includes defining vendor attributes such as payment terms, delivery schedules, and contact information.
The procedure also involves creating purchase orders and managing invoices from the vendor.
Examples of UPS vendors include APC, Eat
The maintenance procedure of DG involves regular checks and servicing to ensure optimal performance.
Regularly check oil and coolant levels
Inspect air filters and replace if necessary
Clean and inspect spark plugs
Check battery and charging system
Perform load bank testing
Schedule routine maintenance with a qualified technician
Keep a maintenance log for record keeping
ATS scheme stands for Automatic Transfer Switch scheme used in power systems.
ATS scheme is used to transfer power supply from one source to another in case of power failure.
It is commonly used in backup power systems to ensure uninterrupted power supply.
ATS scheme can be implemented using mechanical or electronic switches.
It is important to ensure proper coordination between the ATS and protective devices to avoid any ...
Address the issue calmly and professionally, listen to their perspective and try to find a solution together.
Remain calm and avoid getting defensive
Listen to their perspective and try to understand their point of view
Communicate clearly and respectfully
Try to find a solution together
If necessary, involve a mediator or supervisor
Transformer PM involves regular maintenance and inspection to ensure optimal performance.
Perform regular visual inspections to check for signs of wear and tear
Test insulation resistance to ensure it meets standards
Check oil levels and perform oil analysis to detect any contaminants
Inspect and tighten connections
Perform load and temperature tests
Schedule maintenance based on manufacturer recommendations
Examples of maint...
Transformers are protected by various methods to prevent damage from faults and overloads.
Overcurrent protection using fuses or circuit breakers
Thermal protection using temperature sensors and alarms
Buchholz relay protection for detecting internal faults
Differential protection for detecting external faults
Ground fault protection using ground fault relays
Lightning arrestors for protection against lightning strikes
Oil le...
Shapoorji Pallonji Group interview questions for designations
I applied via Naukri.com and was interviewed before Dec 2021. There were 2 interview rounds.
Get interview-ready with Top Shapoorji Pallonji Group Interview Questions
I was interviewed before Oct 2020.
I applied via Walk-in and was interviewed in Aug 2024. There was 1 interview round.
Diesel generator is a backup power source using diesel fuel, transformer is a device that transfers electrical energy between circuits, and HVAC is a system for heating, ventilation, and air conditioning.
Diesel generator: provides backup power using diesel fuel, commonly used in areas with frequent power outages
Transformer: transfers electrical energy between circuits, stepping up or down voltage levels as needed
HVAC: ...
A fire fighting system is a set of equipment and procedures designed to detect, control, and extinguish fires in a building or area.
Includes fire alarms, sprinkler systems, fire extinguishers, and fire hoses
May also involve fire suppression systems like foam or gas
Designed to protect lives and property in the event of a fire
Regular maintenance and testing are crucial to ensure effectiveness
DM plant stands for Demineralization plant, used to remove minerals and salts from water.
DM plant is used in industries to produce demineralized water for various processes.
It consists of ion exchange resins to remove minerals like calcium, magnesium, and salts from water.
The process involves passing water through cation and anion exchange columns to remove ions.
DM plant is essential in power plants, pharmaceutical ind...
ACB, VCB, MCCB, MCB are types of circuit breakers used in electrical systems.
ACB stands for Air Circuit Breaker, used for high voltage applications.
VCB stands for Vacuum Circuit Breaker, used for medium voltage applications.
MCCB stands for Molded Case Circuit Breaker, used for low voltage applications.
MCB stands for Miniature Circuit Breaker, used for residential and commercial applications.
posted on 10 Oct 2024
I applied via Company Website and was interviewed in Sep 2024. There were 2 interview rounds.
RPM stands for Revolutions Per Minute.
RPM stands for Revolutions Per Minute
It is a unit of rotational speed
Commonly used in the context of engines, motors, and other rotating machinery
There are various types of motors including DC motors, AC motors, stepper motors, and servo motors.
DC motors: used in applications where speed control is important, such as in electric vehicles.
AC motors: commonly used in household appliances and industrial machinery.
Stepper motors: used in applications requiring precise position control, like 3D printers.
Servo motors: used in robotics and automation for accurate contr
Earthing is the process of connecting electrical systems to the ground to prevent electric shock and protect equipment.
Earthing provides a path for fault currents to flow safely into the ground.
It helps in stabilizing voltage levels and protecting against lightning strikes.
Earthing is essential for safety in electrical systems to prevent electric shocks.
Examples of earthing systems include grounding rods, grounding pla
Insulators are materials that do not conduct electricity and are used to prevent the flow of current.
Insulators are materials with high resistivity, such as rubber, glass, porcelain, and plastic.
They are used to separate conductors in electrical systems to prevent short circuits.
Insulators are crucial for safety in electrical installations to avoid electric shocks and fires.
posted on 3 May 2024
I applied via Approached by Company and was interviewed before May 2023. There were 2 interview rounds.
posted on 25 Oct 2023
Some of the top questions asked at the Shapoorji Pallonji Group Electrical Engineer interview -
based on 19 reviews
Rating in categories
Deputy Manager
606
salaries
| ₹6 L/yr - ₹16 L/yr |
Senior Engineer
431
salaries
| ₹4 L/yr - ₹12.2 L/yr |
Construction Engineer
305
salaries
| ₹2.4 L/yr - ₹9 L/yr |
Civil Site Engineer
233
salaries
| ₹1.5 L/yr - ₹9.2 L/yr |
Safety Officer
228
salaries
| ₹1.5 L/yr - ₹7.5 L/yr |
Tata Group
Reliance Industries
Adani Group
Mahindra & Mahindra