Filter interviews by
posted on 15 Oct 2023
I was interviewed before Oct 2022.
Top trending discussions
posted on 10 Feb 2025
I was interviewed before Feb 2024.
General Engineering questions
posted on 23 Sep 2024
The current unit refers to the standard unit of measurement being used in a particular context.
The current unit can vary depending on the field or industry, such as inches in construction or Celsius in weather forecasting.
It is important to clarify the current unit to ensure accurate communication and data analysis.
Examples of current units include meters for length, kilograms for weight, and seconds for time.
The resistance unit is the ohm (Ω), which measures the opposition to the flow of electric current.
The resistance unit is measured in ohms (Ω)
It represents the opposition to the flow of electric current
Resistance can be calculated using Ohm's Law: R = V/I, where R is resistance, V is voltage, and I is current
I applied via Walk-in and was interviewed in Mar 2024. There was 1 interview round.
CT current can be calculated by dividing the primary current by the turns ratio of the current transformer.
CT current = Primary current / Turns ratio
Primary current is the current flowing through the primary conductor
Turns ratio is the ratio of the number of turns in the primary winding to the number of turns in the secondary winding
Lockout is a safety procedure used to ensure that machinery or equipment is properly shut off and cannot be restarted until maintenance or servicing is completed.
Lockout involves isolating energy sources to prevent accidental startup.
Lockout devices like padlocks and tags are used to physically lock equipment.
Lockout procedures must be followed to prevent accidents and injuries.
Examples of lockout include locking out e...
IP65 for panel refers to the level of protection against dust and water ingress.
IP65 rating means the panel is dust tight and protected against water jets from any direction.
The first digit '6' indicates the level of protection against solid objects like dust.
The second digit '5' indicates the level of protection against water ingress.
Commonly used in outdoor or industrial applications where the panel may be exposed to...
TCS and Master Trip Relay are protective devices used in electrical systems to prevent damage during faults.
TCS stands for Time Current Characteristic Relay, which operates based on the relationship between time and current to trip the circuit breaker during faults.
Master Trip Relay is a relay that receives signals from various protective relays and initiates a trip signal to disconnect the circuit in case of a fault.
B...
LSC 2A and LSC 2B are standards for lighting in commercial and industrial buildings.
LSC 2A and LSC 2B are part of the Lighting Power Density (LPD) requirements in building codes.
LSC 2A is for commercial buildings while LSC 2B is for industrial buildings.
They specify the maximum allowable power consumption for lighting per unit area in a building.
For example, LSC 2A may require a maximum LPD of 0.9 watts per square foot
REF protection is used to prevent damage to equipment from electrical faults. High impedance protection is used for sensitive equipment, while low impedance protection is used for power systems.
REF protection is used to detect ground faults and prevent damage to equipment.
High impedance protection is used for sensitive equipment that requires high accuracy and low fault currents.
Low impedance protection is used for pow...
ANSI codes are used to identify various types of protection devices in electrical systems.
ANSI code 50/51 is for instantaneous overcurrent protection
ANSI code 67 is for directional power protection
ANSI code 87 is for differential protection
ANSI code 59 is for overvoltage protection
Motor selection for rotary table involves considering torque requirements, speed, size constraints, and control system compatibility.
Consider torque requirements for the rotary table based on load and acceleration/deceleration needs
Select a motor with appropriate speed capabilities to meet the desired rotation speed
Ensure the motor size fits within the constraints of the rotary table design
Check compatibility with the ...
posted on 30 May 2024
I applied via Naukri.com and was interviewed in Nov 2023. There were 4 interview rounds.
Making an animated clip from a reference video provided.
MCB is a miniature circuit breaker used for low currents, while MCCB is a molded case circuit breaker used for higher currents.
MCB is designed for low currents, typically up to 100A, while MCCB is designed for higher currents, typically up to 2500A.
MCB is a compact device with fixed trip settings, while MCCB is larger and has adjustable trip settings.
MCB is commonly used in residential and commercial applications, whil...
A relay is an electrically operated switch that uses an electromagnet to mechanically operate the switch contacts.
Relays are used to control high power circuits with a low power signal.
When the coil of the relay is energized, it creates a magnetic field that causes the switch contacts to close or open.
Relays are commonly used in automotive applications, industrial controls, and home appliances.
There are different types...
posted on 30 Aug 2023
I applied via Naukri.com and was interviewed in Jul 2023. There were 2 interview rounds.
I applied via Recruitment Consulltant and was interviewed before Oct 2022. There were 3 interview rounds.
I have 3 years of experience in sheet metal work, including designing and fabricating components for various projects.
Experience in designing sheet metal components using CAD software
Knowledge of different types of sheet metal materials and their properties
Hands-on experience in fabricating sheet metal parts using various tools and techniques
Ability to interpret engineering drawings and specifications accurately
Experie...
I applied via Recruitment Consulltant and was interviewed in Aug 2022. There were 3 interview rounds.
based on 1 interview
Interview experience
Deputy Manager
1.3k
salaries
| ₹5 L/yr - ₹14.3 L/yr |
Senior Manager
670
salaries
| ₹8.4 L/yr - ₹31 L/yr |
Manager
661
salaries
| ₹6.4 L/yr - ₹22 L/yr |
Assistant Manager
333
salaries
| ₹3.8 L/yr - ₹11.1 L/yr |
Deputy General Manager
311
salaries
| ₹17.4 L/yr - ₹42.2 L/yr |
Siemens
ABB
Honeywell Automation
Emerson Electric Co.