Columns starter can be checked by measuring the distance between the starter bars and the top of the column.
Measure the distance between the starter bars and the top of the column using a measuring tape.
Ensure that the distance is as per the design specifications.
Check for any damages or deformities in the starter bars.
Ensure that the starter bars are properly aligned and fixed in place.
Check for any cracks or damages ...
Beam bottoms can be checked by visual inspection and using a straight edge.
Inspect for any cracks or deformities on the bottom surface of the beam.
Use a straight edge to check for any unevenness or dips in the beam.
Check for any signs of corrosion or rust on the bottom surface of the beam.
Ensure that the beam is properly supported and not sagging.
Check for any signs of water damage or staining on the bottom surface of
The strength developed after 7 days of concrete depends on various factors such as mix design, curing, and environmental conditions.
The strength of concrete after 7 days is typically around 60-70% of its ultimate strength.
Factors such as water-cement ratio, aggregate size and type, and curing methods can affect the strength development.
The strength can be tested using compression tests on concrete cubes or cylinders.
Th...
The cube size of RMC (Ready Mix Concrete) is generally 150mm x 150mm x 150mm.
RMC is a concrete mixture that is manufactured in a batching plant or factory according to a set recipe and then delivered to a work site by truck mounted in-transit mixers.
The cube size of RMC is used to determine the compressive strength of the concrete after it has hardened.
The cube size of RMC is generally 150mm x 150mm x 150mm, but it can...
Bent up bars are provided in beams to resist shear forces and prevent diagonal cracks.
Bent up bars increase the shear resistance of the beam.
They help to prevent diagonal cracks from forming in the beam.
They also help to distribute the load evenly across the beam.
The number and size of bent up bars depend on the design requirements and load capacity of the beam.
Bent up bars are typically placed at the ends of the beam
The length of stirrups hook depends on the diameter of the bar and the spacing of the stirrups.
The hook length should be at least 10 times the diameter of the bar.
The hook should extend beyond the compression zone of the beam.
The spacing between stirrups also affects the length of the hook.
For example, for a 12mm diameter bar and 150mm stirrup spacing, the hook length should be at least 120mm.
Columns can have multiple zones depending on the design and purpose.
The number of zones in a column depends on the design and purpose.
Zones can be created for different load-bearing capacities or aesthetic purposes.
For example, a column in a high-rise building may have multiple zones for different levels of wind resistance.
Another example is a decorative column that may have multiple zones for different patterns or tex...
Lapping length of bars is the length of overlap required for two reinforcement bars to transfer load effectively.
It is necessary to provide lapping length to ensure the continuity of reinforcement bars.
The lapping length depends on the diameter of the bars, the grade of concrete, and the design load.
The lapping length is usually 50 times the diameter of the bar for tension reinforcement and 40 times the diameter of the...
The level of slab can be checked using a spirit level or laser level.
Place the spirit level or laser level on the slab surface.
Check the bubble in the spirit level or laser beam to ensure it is level.
Repeat the process at different locations on the slab to ensure it is level throughout.
If the slab is not level, adjustments can be made by adding or removing material.
Ensure the slab is level before proceeding with furthe
Slab thickness can be checked during pouring by using various methods.
Use a laser level to check the thickness of the slab at various points.
Use a measuring tape to measure the thickness of the slab at various points.
Use a dipstick to measure the thickness of the slab at various points.
Ensure that the formwork is set up correctly to the required thickness.
Check the mix design and slump of the concrete to ensure the cor...
Top trending discussions
I applied via Recruitment Consulltant and was interviewed before Oct 2022. There were 2 interview rounds.
Construction and maintenance of GIS buildings involves planning, design, construction, and ongoing upkeep of the facility.
GIS building construction requires detailed planning and design to ensure the facility meets the specific needs of the project.
Regular maintenance is essential to keep the GIS building in optimal condition and prevent costly repairs in the future.
Maintenance tasks may include HVAC system checks, roo...
I applied via Approached by Company and was interviewed in Mar 2023. There were 2 interview rounds.
TMT stands for Thermo-Mechanically Treated reinforcement bars used in construction.
TMT bars are made by subjecting mild steel bars to a combination of heat treatment and mechanical deformation.
This process imparts greater strength and ductility to the bars, making them ideal for use in construction.
TMT bars are widely used in reinforced concrete structures such as buildings, bridges, and dams.
They offer superior corros...
500D means the yield strength of TMT bars is 500 MPa.
500D is a grade of TMT bars used in construction.
The 'D' stands for ductility, which is the ability of the material to deform without breaking.
The yield strength of 500D TMT bars is 500 MPa.
These bars are commonly used in high-rise buildings, bridges, and other structures that require high strength and durability.
The required steel at the percentage concrete depends on the design and specifications of the structure.
The amount of steel reinforcement needed in concrete is determined by the design and specifications of the structure.
Factors such as the size and shape of the structure, the loads it will bear, and the desired strength and durability of the concrete will all affect the required steel percentage.
The steel percentage c...
Stress is the force applied per unit area, while strain is the deformation caused by stress.
Stress is a measure of the internal forces within a material, while strain is the measure of the deformation of the material.
Stress is expressed in units of force per unit area, while strain is expressed as a ratio of the change in length or shape to the original length or shape.
Stress and strain are related by the material's el...
The stress failure at brick wall can be due to compressive or tensile stress.
Compressive stress failure occurs when the brick wall is unable to withstand the weight or load placed on it.
Tensile stress failure occurs when the brick wall is unable to withstand the forces that pull it apart.
Cracking, bulging, or collapse of the wall can be signs of stress failure.
Reinforcing the wall with steel bars or using thicker brick
White marble is a metamorphic rock composed of recrystallized carbonate minerals, mainly calcite or dolomite.
It is commonly used in construction and sculpture.
It is formed from limestone or dolomite that has undergone heat and pressure.
It is often found in quarries in countries such as Italy, Greece, and India.
Standard coarse sand size ranges from 2.0mm to 4.75mm.
Standard coarse sand is commonly used in construction and civil engineering projects.
It is typically graded between 2.0mm to 4.75mm in size.
This type of sand is often used as a base material for concrete and asphalt.
It can also be used for drainage systems and as a bedding material for pipes.
The size and shape of the sand particles can affect the strength and durabi
I applied via Recruitment Consulltant and was interviewed before Oct 2022. There were 2 interview rounds.
Construction and maintenance of GIS buildings involves planning, design, construction, and ongoing upkeep of the facility.
GIS building construction requires detailed planning and design to ensure the facility meets the specific needs of the project.
Regular maintenance is essential to keep the GIS building in optimal condition and prevent costly repairs in the future.
Maintenance tasks may include HVAC system checks, roo...
I applied via Naukri.com and was interviewed before Jan 2023. There was 1 interview round.
The size of a slump cone is a tool used in concrete testing to measure the consistency of fresh concrete.
The size of a slump cone is typically 12 inches in height.
The base diameter of a slump cone is usually 8 inches.
The top diameter of a slump cone is typically 4 inches.
The size of a slump cone may vary depending on specific testing requirements or standards.
The dimensions of a slump cone are important for accurate me...
To estimate aggregate quantity for a 200sqmt slab, calculate the volume of concrete required and then determine the aggregate quantity based on the mix ratio.
Calculate the volume of concrete required for the slab
Determine the mix ratio of concrete (e.g., 1:2:4)
Calculate the volume of aggregates needed based on the mix ratio
Consider the bulk density of aggregates to convert volume to weight
Account for wastage and add a
Before casting, civil engineers need to check the quality of various elements.
Quality of concrete mix
Quality of reinforcement bars
Quality of formwork
Quality of water used in the mix
Quality of curing process
The number of cubes required for 250 cubic meters of concrete depends on the size of the cubes.
The size of the cubes needs to be specified to determine the number required.
The volume of each cube needs to be calculated.
Divide the total volume of concrete (250 cubic meters) by the volume of each cube to get the number of cubes required.
For example, if the cubes are 1 cubic meter in size, then 250 cubes would be needed.
Post concrete quality inspection involves evaluating the quality of concrete after it has been placed and hardened.
Inspect the concrete for any visible defects such as cracks, honeycombing, or segregation.
Check the concrete strength by conducting compressive strength tests on samples taken from the structure.
Assess the concrete's durability by examining its resistance to factors like freeze-thaw cycles or chemical expo...
I applied via Naukri.com and was interviewed before Dec 2022. There were 2 interview rounds.
I applied via Walk-in and was interviewed in May 2022. There were 2 interview rounds.
M20 grade of concrete has a compressive strength of 20 N/mm² after 28 days.
M20 grade of concrete is a mix of 1:1.5:3 cement, sand, and aggregate respectively.
It is commonly used for residential and commercial construction.
The compressive strength of M20 grade concrete after 28 days is 20 N/mm².
This strength can be achieved by proper curing and water-cement ratio.
I applied via Monster and was interviewed in Dec 2021. There was 1 interview round.
I applied via Recruitment Consulltant and was interviewed before Dec 2021. There were 2 interview rounds.
based on 1 review
Rating in categories
Accountant
6
salaries
| ₹1 L/yr - ₹4 L/yr |
Site Engineer
6
salaries
| ₹3.3 L/yr - ₹3.6 L/yr |
Junior Accountant
4
salaries
| ₹2.2 L/yr - ₹2.5 L/yr |
Telecalling Executive
4
salaries
| ₹0.8 L/yr - ₹2.2 L/yr |
Data Entry Operator
4
salaries
| ₹1.2 L/yr - ₹3.5 L/yr |
ABC Consultants
Kelly Services
Randstad
Team Lease