I applied via Company Website and was interviewed in Jun 2023. There were 3 interview rounds.
Initial and Routine Pile Load Tests are conducted to assess the load-bearing capacity and performance of piles.
Initial Pile Load Test is performed on a single pile to determine its ultimate load capacity and settlement behavior.
Routine Pile Load Test is conducted on a representative sample of piles to verify the design assumptions and ensure the desired performance.
Initial Pile Load Test involves applying a gradually i...
Performance test of elastomeric bearings evaluates their ability to withstand load, deformation, and environmental conditions.
Performance test assesses the load-carrying capacity of elastomeric bearings.
It measures the deformation and displacement under different loads.
Tests evaluate the behavior of bearings under various environmental conditions like temperature and moisture.
Performance tests ensure the durability, st...
Top trending discussions
I applied via Naukri.com and was interviewed in Sep 2022. There were 3 interview rounds.
Oil and gas refienry project as a execution construction engineer .
I applied via Recruitment Consultant and was interviewed before Oct 2020. There was 1 interview round.
I applied via Walk-in and was interviewed in Aug 2023. There was 1 interview round.
I applied via Referral and was interviewed before Aug 2020. There was 1 interview round.
I applied via Company Website and was interviewed before Oct 2021. There were 3 interview rounds.
Concrete temperature refers to the temperature of freshly mixed concrete.
Concrete temperature affects the setting time and strength development of concrete.
It is important to control the temperature of concrete during mixing, transportation, and placement.
High temperatures can accelerate the setting time and reduce workability, while low temperatures can slow down setting and strength gain.
Concrete temperature is typic...
Precocious of water structure joint refers to the ability of a joint to withstand water pressure and prevent leakage.
Water structure joints should be designed and constructed to be watertight.
Various types of joints can be used in water structures, such as expansion joints, construction joints, and control joints.
Proper sealing materials and techniques should be employed to ensure the integrity of the joints.
Regular in...
Cube test results are used to determine the compressive strength of concrete at 7 and 28 days.
Cube test involves casting cubes of concrete and testing them under compression
Results are reported in terms of compressive strength in MPa or psi
7-day results are used to determine early strength and 28-day results are used to determine ultimate strength
Concrete with a compressive strength of at least 20 MPa is considered sui
I was interviewed before May 2016.
I applied via Company Website and was interviewed before Oct 2021. There were 3 interview rounds.
Flow calculation on orifice plate
Determine the differential pressure across the orifice plate
Calculate the flow rate using the orifice equation
Consider the fluid properties and orifice plate dimensions
Control systems are used to manage and regulate processes or machines.
Control systems use sensors to measure inputs and outputs to adjust the system accordingly.
They can be open-loop or closed-loop systems.
Examples include thermostats, cruise control in cars, and autopilot in airplanes.
Control systems can be designed using various techniques such as PID control, fuzzy logic, and neural networks.
I applied via Company Website and was interviewed in Jan 2022. There were 2 interview rounds.
based on 1 interview
Interview experience
based on 4 reviews
Rating in categories
Civil Engineer
139
salaries
| ₹0 L/yr - ₹0 L/yr |
Mechanical Engineer
108
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
102
salaries
| ₹0 L/yr - ₹0 L/yr |
Inspection Engineer
92
salaries
| ₹0 L/yr - ₹0 L/yr |
Engineer
91
salaries
| ₹0 L/yr - ₹0 L/yr |
Ircon International
Mecon
BHEL
Container Corporation of India