i
Privi Speciality Chemicals
Filter interviews by
I prioritize based on urgency, assess available information, consult with team if needed, and make a quick decision.
Prioritize based on urgency of the situation
Assess available information quickly
Consult with team members if needed
Make a quick decision based on the information gathered
I applied via Recruitment Consultant and was interviewed before Aug 2020. There was 1 interview round.
Gas Chromatography is a technique used to separate and analyze volatile compounds in a mixture.
Gas Chromatography separates compounds based on their volatility and affinity for the stationary phase.
It involves the use of a carrier gas to carry the sample through a column packed with a stationary phase.
The compounds in the sample interact differently with the stationary phase, leading to separation.
The separated compoun...
Top trending discussions
I applied via Newspaper Ad and was interviewed in Apr 2022. There were 4 interview rounds.
I applied via Recruitment Consulltant and was interviewed in Feb 2022. There were 5 interview rounds.
Gas chromatography is a technique used to separate and analyze volatile compounds in a mixture.
Gas chromatography involves the use of a stationary phase and a mobile phase.
The stationary phase is a solid or liquid coating inside a column, while the mobile phase is a gas.
The mixture is injected into the column, and as the mobile phase flows through, different compounds interact with the stationary phase at different rat...
Buffer solutions with known pH values are used for pH meter calibration.
Buffer solutions with pH values of 4.01, 7.00, and 10.01 are commonly used for pH meter calibration.
The choice of buffer solution depends on the pH range of the sample being tested.
The buffer solutions should be stored properly and replaced regularly to ensure accurate calibration.
Calibration should be performed before each use of the pH meter.
Total productivity Maintenance
Handling of HPLC GC and all other instruments used in Quality control department
I applied via Referral and was interviewed before Dec 2021. There were 2 interview rounds.
I applied via Campus Placement and was interviewed before Jan 2021. There were 2 interview rounds.
Basic test
I applied via Recruitment Consultant and was interviewed in Oct 2018. There were 3 interview rounds.
GC and HPLC troubleshooting involves identifying and resolving issues with the instruments and their components.
Check for leaks in the system
Verify proper calibration of detectors
Inspect and clean columns
Ensure proper sample preparation
Check for proper flow rates and pressures
Verify proper functioning of pumps and valves
I applied via Referral and was interviewed in Apr 2023. There were 3 interview rounds.
The length of GC column varies depending on the type and manufacturer.
GC columns can range from 10-100 meters in length.
The length of the column affects the separation of compounds.
Longer columns provide better separation but require more time and may have higher costs.
The length of the column should be chosen based on the specific analysis needs.
Different types of columns may have different optimal lengths.
The length of HPLC column varies depending on the application and type of column used.
The length of HPLC column can range from 30 mm to 300 mm.
Shorter columns are used for faster separations while longer columns are used for higher resolution.
The length of the column can also affect the retention time of the analyte.
For example, a C18 column with a length of 150 mm is commonly used for routine analysis of pharmaceutica
HPLC and GC are both analytical techniques used to separate and analyze compounds, but they differ in their principles and applications.
HPLC stands for High Performance Liquid Chromatography, while GC stands for Gas Chromatography.
HPLC is used for separating and analyzing compounds that are soluble in liquid, while GC is used for separating and analyzing compounds that are volatile and can be vaporized.
HPLC uses a liqu...
Seeking new challenges and growth opportunities in a dynamic and innovative organization.
Desire for professional development and advancement
Looking for a more challenging role
Seeking a change in work environment
Want to broaden skill set and gain new experiences
The goal of this company is to provide high-quality products and services to customers.
Deliver exceptional quality products
Ensure customer satisfaction
Continuously improve processes and systems
Maintain a strong reputation in the industry
I applied via Campus Placement
Moderate level question and some twisted question
I applied via LinkedIn and was interviewed in Jun 2023. There were 2 interview rounds.
Exp, how to working in process line , HAccp , Vaccp , Taccp .
Interview experience
based on 3 reviews
Rating in categories
Production Officer
35
salaries
| ₹1.7 L/yr - ₹4.5 L/yr |
Officer
26
salaries
| ₹1.7 L/yr - ₹5.5 L/yr |
Assistant Manager
21
salaries
| ₹7.1 L/yr - ₹13.7 L/yr |
Executive Production
21
salaries
| ₹4.1 L/yr - ₹8.5 L/yr |
Senior Executive
18
salaries
| ₹6 L/yr - ₹12.7 L/yr |
Aarti Industries
Vinati Organics
Atul
Solvay Specialities