Filter interviews by
I applied via Recruitment Consulltant
Electrical panels can be used by various types of contractors.
Electrical contractors are the most common type of contractors who use electrical panels.
General contractors may also use electrical panels for specific projects.
HVAC contractors may require electrical panels for their heating and cooling systems.
Plumbing contractors may need electrical panels for water heaters or pumps.
Fire protection contractors may use el...
Various types of MCBs are used in the panel.
Type B MCB for general purpose circuits
Type C MCB for circuits with inductive loads
Type D MCB for circuits with high inrush currents
Type K MCB for circuits with high inrush currents and motors
Type Z MCB for circuits with DC components
Type F MCB for circuits with sensitive equipment
Type G MCB for circuits with surge protection
Type L MCB for lighting circuits
AC current changes direction periodically while DC current flows in one direction only.
AC current is used in household appliances while DC current is used in batteries and electronic devices.
AC current can be easily transformed into different voltages using a transformer while DC current cannot.
AC current is more dangerous to humans than DC current because it can cause muscle contractions.
DC current is more efficient f...
Voltage is the measure of electric potential difference between two points in a circuit.
Voltage is measured in volts (V).
It is the force that drives electric current through a circuit.
Voltage can be positive or negative depending on the direction of the current flow.
A battery provides a voltage difference between its terminals to power a circuit.
Voltage drop occurs when there is a decrease in voltage along a circuit du
The question is unclear. Please provide more context.
Please provide more information about the fault.
Are you asking about fault-finding techniques or the number of people required to find a fault?
Without more context, it is difficult to provide a specific answer.
Transformer safety parts include fuses, circuit breakers, and grounding systems.
Fuses protect against overcurrent and short circuits.
Circuit breakers protect against overloads and faults.
Grounding systems prevent electrical shock and protect equipment.
Other safety parts may include temperature sensors and pressure relief devices.
Capacitors are used to store and release electrical energy in circuits.
Capacitors can filter out noise and stabilize voltage in power supplies.
They can also be used in timing circuits and oscillators.
Capacitors are commonly used in audio equipment to filter out unwanted frequencies.
They can also be used in electric motors to improve power factor and efficiency.
Capacitors are essential components in electronic devices a
A sun t relay is a type of time-delay relay used in electrical systems.
It is used to control the operation of a circuit based on a time delay.
It is commonly used in lighting systems to delay turning on or off.
It can also be used in motor control circuits to prevent damage from sudden power surges.
The delay time can be adjusted to suit the specific needs of the circuit.
It works by using a small current to charge a capac...
Under voltage can cause major electrical problems.
Under voltage can cause equipment damage and failure.
It can also lead to power outages and disruptions.
Proper monitoring and maintenance can prevent under voltage issues.
Examples of under voltage problems include brownouts and voltage sags.
I was interviewed in Jan 2025.
Safety:
* What are the most important safety precautions for scaffold workers?
* How often should scaffolds be inspected?
* What types of personal protective equipment (PPE) should be used when working on scaffolds?
Construction:
* What are the different types of scaffolding?
* How are scaffolds constructed?
* What types of materials are used to construct scaffolds?
* How are scaffolds secured?
* Problem-solving: Scaffolding construction can present various challenges, such as limited space or different types of surfaces. This type of test assesses how quickly and effectively you can find solutions to these problems.
* Mathematical ability: Scaffolding construction requires a basic understanding of mathematics, such as addition, subtraction, multiplication, and division. You also need to know how to measure length, width, and height.
* Spatial reasoning: In scaffolding construction, it's essential to understand where each component will be placed and how it will fit together. This requires understanding how objects are connected to each other and how they appear in space.
* Physical ability: Scaffolding construction demands physical effort and strength. Therefore, some tests may also evaluate your physical fitness.
I was interviewed in Dec 2024.
As I am shift incharge ,i wanted technical knowledge
Very interesting knowledge Questions should ask for interview
I applied via Recruitment Consulltant and was interviewed in Oct 2024. There were 2 interview rounds.
Precautions for working at height include proper training, use of fall protection equipment, regular inspection of equipment, and securing tools and materials.
Ensure workers are properly trained on working at height procedures
Use appropriate fall protection equipment such as harnesses, lanyards, and guardrails
Regularly inspect all equipment used for working at height to ensure it is in good condition
Secure tools and ma...
A lifting plan is a detailed document outlining the procedures and precautions to be taken when lifting heavy objects.
A lifting plan should include the weight of the object being lifted
It should specify the equipment to be used for lifting
The plan should outline the steps to be taken to ensure the safety of workers involved
It should also consider factors such as the location of the lift and any potential hazards
Regular...
Risk assessment is the process of identifying, analyzing, and evaluating potential risks in order to determine the likelihood and impact of harmful events.
Identifying potential hazards and risks in the workplace or environment
Analyzing the likelihood of these risks occurring
Evaluating the potential impact of these risks on people, property, and the environment
Developing strategies to mitigate or eliminate these risks
Re...
Capacity of wire rope sling can be calculated by considering factors like diameter, material, and configuration.
Capacity is determined by the breaking strength of the wire rope and the design factor used.
Calculate the breaking strength of the wire rope by multiplying the area of the rope cross-section by the tensile strength of the material.
Consider the configuration of the sling (single leg, double leg, etc.) and appl...
Power Mech Projects interview questions for popular designations
Get interview-ready with Top Power Mech Projects Interview Questions
I applied via Naukri.com and was interviewed in Aug 2024. There was 1 interview round.
Stored material refers to any items or products that are kept in a designated storage area for future use or distribution.
Stored material can include inventory, supplies, equipment, and raw materials.
Examples of stored material in a retail setting may include clothing, electronics, and household goods.
Proper organization and labeling of stored material is essential for efficient inventory management.
Regular inventory c...
Raw materials are the basic materials used in the production of goods.
Raw materials are the basic materials used in the production of goods
Examples include wood, metal, plastic, fabric, chemicals, etc.
Stored raw materials need to be properly organized and managed to ensure efficient production processes
Group Discussion - Operation & Maintenance
I applied via Referral and was interviewed in Aug 2023. There were 2 interview rounds.
Standard deviation is a measure of the amount of variation or dispersion of a set of values.
Standard deviation is calculated by taking the square root of the variance.
It is used to quantify the amount of variation or dispersion of a set of values.
Higher standard deviation indicates more spread out data points, while lower standard deviation indicates data points are closer to the mean.
It is commonly used in quality con...
To clear NCR, identify root cause, implement corrective actions, verify effectiveness, and close out the NCR.
Identify the root cause of the non-conformance.
Implement corrective actions to address the root cause.
Verify the effectiveness of the corrective actions through testing or inspection.
Close out the NCR once the corrective actions have been successful.
Document all steps taken in the NCR clearance process.
Testing procedure for coarse aggregate involves determining its physical properties and quality through various tests.
Conduct sieve analysis to determine particle size distribution
Perform specific gravity and absorption test to assess porosity
Check for shape, surface texture, and angularity through visual inspection
Test for resistance to abrasion and impact to evaluate durability
Silt content limit as per IS code is 3% for fine aggregate.
Silt content limit for fine aggregate as per IS code is 3%.
Excessive silt content can affect the quality of concrete.
Silt content can be determined by conducting a sieve analysis test.
Top trending discussions
The duration of Power Mech Projects interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 104 interviews
Interview experience
based on 1.6k reviews
Rating in categories
Senior Engineer
486
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
340
salaries
| ₹0 L/yr - ₹0 L/yr |
Engineer
255
salaries
| ₹0 L/yr - ₹0 L/yr |
Mechanical Engineer
242
salaries
| ₹0 L/yr - ₹0 L/yr |
Electrical Engineer
215
salaries
| ₹0 L/yr - ₹0 L/yr |
Thermax Limited
BGR Energy Systems
Larsen & Toubro Limited
Kalpataru Projects International