I applied via Company Website and was interviewed in Dec 2024. There were 3 interview rounds.
CVT in transmission line works by continuously varying the gear ratio to provide smooth acceleration and optimal engine performance.
CVT uses a belt and pulley system to vary the gear ratio based on engine speed and load
It provides seamless acceleration without the need for traditional gear shifts
CVT allows the engine to operate at its most efficient RPM range for better fuel economy
Examples of vehicles with CVT include
A wave trap is a device used in electrical systems to filter out unwanted high-frequency signals.
Wave traps are typically used in power systems to prevent high-frequency currents from flowing back into the system.
They are designed to have a high impedance at the frequency of the unwanted signal, effectively blocking it from passing through.
Wave traps can be installed on transmission lines or connected to transformers t...
Testing of transformer involves various electrical tests to ensure its performance and safety.
Routine tests include turns ratio test, insulation resistance test, and winding resistance test.
Type tests include temperature rise test, impulse test, and short circuit test.
Special tests may include partial discharge test and noise level test.
Testing is crucial to ensure the transformer meets specifications and standards for...
PRV stands for Pressure Relief Valve, a safety device designed to protect equipment from overpressure by releasing excess pressure.
PRVs are commonly used in industries such as oil and gas, chemical, and manufacturing.
They are designed to open when the pressure inside a system exceeds a certain set point, allowing the excess pressure to be released.
PRVs help prevent catastrophic failures and protect equipment from damag...
Top trending discussions
I applied via Walk-in and was interviewed in Dec 2020. There were 3 interview rounds.
The company culture is collaborative, innovative, and focused on continuous improvement.
Employees are encouraged to share ideas and work together to solve problems.
The company values creativity and rewards employees who come up with innovative solutions.
There is a strong emphasis on learning and development, with opportunities for training and career growth.
The company is committed to sustainability and social responsi...
I applied via Referral and was interviewed before Jul 2021. There was 1 interview round.
A multimeter is an electronic device used to measure voltage, current, and resistance in electrical circuits.
It can measure AC and DC voltage
It can measure AC and DC current
It can measure resistance
It can also measure other electrical parameters such as capacitance and frequency
It typically has a digital display for easy reading
Examples of multimeter brands include Fluke, Klein Tools, and Extech
I applied via LinkedIn and was interviewed in Mar 2022. There were 2 interview rounds.
Answering questions related to transformer tests, BDB value, relay types, pole types, and conductor ground clearance in 33kv.
Transformer tests include insulation resistance, turns ratio, and polarity tests.
BDB value refers to the breakdown voltage of insulating oil.
Types of relays include overcurrent, differential, and distance relays.
Types of poles used in 33kv include wooden, steel, and concrete poles.
Conductor groun...
I applied via Walk-in and was interviewed in Jun 2022. There were 3 interview rounds.
CT and PT are electrical transformers used in power systems to measure current and voltage respectively.
CT stands for Current Transformer and is used to measure high currents in power systems.
PT stands for Potential Transformer and is used to measure high voltages in power systems.
CTs are connected in series with the load while PTs are connected in parallel with the load.
CTs are used to measure current for protection a...
I applied via Walk-in and was interviewed in Jul 2023. There were 2 interview rounds.
To protect a transformer, measures such as overcurrent protection, temperature monitoring, and proper grounding should be implemented. VFD stands for Variable Frequency Drive, a device used to control the speed of an electric motor.
Implement overcurrent protection to prevent excessive current flow through the transformer.
Monitor the temperature of the transformer using temperature sensors to prevent overheating.
Ensure ...
I applied via Walk-in and was interviewed in Jan 2023. There were 3 interview rounds.
I applied via Naukri.com and was interviewed in Jan 2021. There was 1 interview round.
based on 1 interview
Interview experience
Field Engineer
209
salaries
| ₹0 L/yr - ₹0 L/yr |
Field Supervisor
85
salaries
| ₹0 L/yr - ₹0 L/yr |
Graduate Apprentice Trainee
65
salaries
| ₹0 L/yr - ₹0 L/yr |
Electrical Engineer
63
salaries
| ₹0 L/yr - ₹0 L/yr |
Associate Engineer
58
salaries
| ₹0 L/yr - ₹0 L/yr |
NTPC
BHEL
Tata Power
Adani Power