Filter interviews by
I appeared for an interview before Feb 2024.
Related to a recent issue.
I appeared for an interview in Jul 2022.
400 kv hardware detected - need more context to provide answer
What type of hardware is being referred to?
What is the context of the detection?
What are the potential implications of the detection?
What steps need to be taken next?
Top trending discussions
I applied via Referral and was interviewed before Jul 2021. There was 1 interview round.
I applied via Company Website and was interviewed in Sep 2021. There were 3 interview rounds.
I applied via Company Website and was interviewed in Feb 2022. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Dec 2020. There were 4 interview rounds.
VCB, SF6, CT, PT, LA are all electrical equipment used in power systems.
VCB stands for Vacuum Circuit Breaker and is used for switching and protection of electrical power systems.
SF6 is a gas used as an insulating medium in high voltage electrical equipment such as circuit breakers, switchgear, and transformers.
CT stands for Current Transformer and is used to measure electrical current in power systems.
PT stands for Po...
Copper and aluminum are commonly used conductors in transmission.
Copper is an excellent conductor due to its high electrical conductivity.
Aluminum is also widely used as it is lightweight and cost-effective.
Other conductors like silver and gold are rarely used due to their high cost.
Copper-clad steel conductors are used in specific applications where strength is required.
Different types of tests related to transformers include routine tests, type tests, and special tests.
Routine tests are performed on every transformer and include measurement of winding resistance, insulation resistance, and voltage ratio.
Type tests are performed on a sample transformer to verify its design and include temperature rise test, impulse test, and short-circuit test.
Special tests are performed on transforme...
Different types of faults refer to the various abnormalities that can occur in an electrical system.
Short circuit fault
Open circuit fault
Ground fault
Overvoltage fault
Undervoltage fault
Overcurrent fault
Undercurrent fault
Relays are switches that open and close circuits electromechanically or electronically. There are various types of relays.
Electromechanical relays
Solid-state relays
Reed relays
Polarized relays
Time-delay relays
Overload protection relays
Mercury-wetted relays
Latching relays
Machine tool relays
Thermal relays
I applied via Walk-in and was interviewed in Feb 2022. There were 3 interview rounds.
I applied via Walk-in and was interviewed in Jul 2023. There were 2 interview rounds.
To protect a transformer, measures such as overcurrent protection, temperature monitoring, and proper grounding should be implemented. VFD stands for Variable Frequency Drive, a device used to control the speed of an electric motor.
Implement overcurrent protection to prevent excessive current flow through the transformer.
Monitor the temperature of the transformer using temperature sensors to prevent overheating.
Ensure ...
based on 2 interviews
Interview experience
based on 25 reviews
Rating in categories
Field Engineer
216
salaries
| ₹3.6 L/yr - ₹10 L/yr |
Field Supervisor
84
salaries
| ₹4.1 L/yr - ₹6.5 L/yr |
Electrical Engineer
63
salaries
| ₹1.7 L/yr - ₹9.1 L/yr |
Associate Engineer
61
salaries
| ₹2.4 L/yr - ₹4.6 L/yr |
Graduate Apprentice Trainee
60
salaries
| ₹1 L/yr - ₹2.8 L/yr |
Suzlon Group
Adani Group
NTPC
Torrent Power