Q1. How much are you proficient in Autocad layout design for HVAC system?
I am highly proficient in Autocad layout design for HVAC systems.
I have extensive experience in using Autocad for designing HVAC systems.
I am skilled in creating detailed 2D and 3D models of HVAC systems using Autocad.
I am familiar with industry standards and codes related to HVAC design and can incorporate them into my designs.
I have worked on various projects involving HVAC design using Autocad, including commercial buildings, hospitals, and residential complexes.
I am able ...read more
Q2. Calculate Duct size in Duct sizer software for 3500 CFM and 0.0112 ich of wg friction?
Duct size for 3500 CFM and 0.0112 ich of wg friction in Duct sizer software.
Open Duct sizer software
Enter 3500 CFM and 0.0112 ich of wg friction
Calculate duct size
Q3. What is Infiltration?
Infiltration refers to the unintentional or unwanted entry of outside air into a building or space.
Infiltration can occur through cracks, gaps, or openings in the building envelope.
It can lead to energy loss, poor indoor air quality, and discomfort for occupants.
Infiltration can be reduced through proper sealing and insulation of the building envelope.
Examples of infiltration include drafts around windows and doors, and air leakage through walls and roofs.
Q4. What is AHU?
AHU stands for Air Handling Unit.
AHU is a device used to regulate and circulate air as part of a heating, ventilation, and air conditioning (HVAC) system.
It typically consists of a fan, heating and cooling coils, filters, dampers, and controls.
AHUs are responsible for conditioning and distributing air to different areas of a building.
They can be found in various settings such as commercial buildings, hospitals, and industrial facilities.
Examples of AHUs include rooftop units,...read more
Q5. What is Heat Load?
Heat load refers to the amount of heat that needs to be removed or added to a space to maintain a desired temperature.
Heat load is calculated based on factors such as the size of the space, the number of occupants, the amount of equipment in the space, and the climate.
It is important to accurately calculate heat load in order to properly size HVAC equipment and ensure efficient operation.
Examples of factors that can increase heat load include large windows, high ceilings, and...read more
Q6. What is ACH?
ACH stands for Air Changes per Hour, which is a measure of the number of times the air in a room is replaced with fresh air in an hour.
ACH is an important factor in determining the indoor air quality of a space.
It is calculated by dividing the volume of air in a room by the amount of fresh air introduced in an hour.
ASHRAE recommends a minimum of 4 ACH for residential spaces and 6 ACH for commercial spaces.
Higher ACH values may be required for spaces with high occupancy or whe...read more